Thermo-Induced Shape-Memory PEG-PCL Copolymer as a Dual-Drug-Eluting Biodegradable Stent
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this work, a thermo-induced shape-memory drug-eluting stent (SMDES) has been developed by cross-linking PEG-PCL copolymer (cPEG-PCL). The stent is able to perform the shape-memory effect from a temporary linear form to a permanent spiral shape with the transition temperature close to body temperature. The stent incorporates a controlled dual drug-release system for the purpose of preventing in-stent restenosis of the vessel for short- and long-term therapeutic effects. From the results, (1)H NMR and GPC indicate that the compositions of PEG-PCL block copolymers are similar to the feed ratios of PEG/ε-CL. A Young's modulus of the cPEG-PCL stent can be achieved that ranges from tens to one hundred megapascals by modulation of the mixing ratio of PEG/PCL. The cPEG-PCL stent is demonstrated to recover to its permanent shape with a high fixing ratio (>99%), recovery ratio (>90%), and recovery time (<10 s). DSC data reveals that the transition temperature is around body temperature (40 °C). Cytotoxicity tests prove that the cPEG-PCL_6040 stent has good biocompatibility. In vitro degradation tests show that the cPEG-PCL_6040 stent undergoes a bulk degradation of 47% after 60 days of incubation under flow conditions. Platelet adhesion and smooth muscle cell proliferation were significantly inhibited by coculture with a mitomycin C/curcumin-eluting stent as a result of the release of curcumin for antiplatelet adhesion during the initial 2 weeks followed by long-term inhibition of smooth muscle cell hyperproliferation for 60 days via mitomycin C. After 60 days of incubation in a bioreactor, the appearance of the stent remains intact and shows no signs of recoiling or collapse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable, Elastic Shape-Memory Polymers for Potential Biomedical Applications
Lendlein, A., & Langer, R. (2002) · Science · doi:10.1126/science.1066102 · Cited by 2,146
Yakacki, C. M., Shandas, R., Lanning, C., Rech, B., Eckstein, A., & Gall, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.030 · Cited by 618
Platelets in inflammation and thrombosis
Wagner, D. D., & Burger, P. C. (2003) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000095974.95122.ec · Cited by 570
Cited by
Recent Advances in Shape Memory Soft Materials for Biomedical Applications
Chan, B. Q. Y., Low, Z. W. K., Heng, S. J. W., Chan, S. Y., Owh, C., & Loh, X. J. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b01295 · Cited by 377
Materials and methods for delivery of biological drugs
Zelikin, A. N., Ehrhardt, C., & Healy, A. M. (2016) · Nature Chemistry · doi:10.1038/nchem.2629 · Cited by 315
Multiple and two-way reversible shape memory polymers: Design strategies and applications
Wang, K., Jia, Y.-G., Zhao, C., & Zhu, X. X. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100572 · Cited by 208
PCL-Based Shape Memory Polymer Semi-IPNs: The Role of Miscibility in Tuning the Degradation Rate
Pfau, M. R., McKinzey, K. G., Roth, A. A., & Grunlan, M. A. (2020) · Biomacromolecules · doi:10.1021/acs.biomac.0c00454 · Cited by 58
Yin, G., Zhao, D., Wang, X., Ren, Y., Zhang, L., Wu, X., Nie, S., & Li, Q. (2015) · RSC Advances · doi:10.1039/c5ra15531b · Cited by 28
Metadata
- Authors
- Yang, C.-S., Wu, H.-C., Sun, J.-S., Hsiao, H.-M., & Wang, T.-W.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-11-01
- Volume
- 5
- Issue
- 21
- Pages
- 10985-10994
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2314385105
- Cited by
- 133
- References
- 3
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.