The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
The Influence of Surface Modification on Bacterial Adhesion to Titanium-Based Substrates
Open accessAbstract
This study examines bacterial adhesion on titanium-substrates used for bone implants. Adhesion is the most critical phase of bacterial colonization on medical devices. The surface of titanium was modified by hydrothermal treatment (HT) to synthesize nanostructured TiO2-anatase coatings, which were previously proven to improve corrosion resistance, affect the plasma protein adsorption, and enhance osteogenesis. The affinity of the anatase coatings toward bacterial attachment was studied by using a green fluorescent protein-expressing Escherichia coli (gfp-E. coli) strain in connection with surface photoactivation by UV irradiation. We also analyzed the effects of surface topography, roughness, charge, and wettability. The results suggested the dominant effects of the macroscopic surface topography, as well as microasperity at the surface roughness scale, which were produced during titanium machining, HT treatment, or both. Macroscopic grooves provided a preferential site for bacteria deposit within the valleys, while the microscopic roughness of the valleys determined the actual interaction surface between bacterium and substrate, resulting in an "interlocking" effect and undesired high bacterial adhesion on nontreated titanium. In the case of TiO2-coated samples, the nanocrystals reduced the width between the microasperities and thus added nanoroughness features. These factors decreased the contact area between the bacterium and the coating, with consequent lower bacterial adhesion (up to 50% less) in comparison to the nontreated titanium. On the other hand, the pronounced hydrophilicity of one of the HT-coated discs after pre-irradiation seemed to enhance the attachment of bacteria, although the increase was not statistically significant (p > 0.05). This observation may be explained by the acquired similar degree of wetting between gfp-E. coli and the coating. No correlation was found between the bacterial adhesion and the ζ-values of the samples in PBS, so the effect of surface charge was considered negligible in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Titanium dioxide photocatalysis
Fujishima, A., Rao, T. N., & Tryk, D. A. (2000) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/s1389-5567(00)00002-2 · Cited by 7,916
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
Interfacial Forces in Aqueous Media
van Oss, C. J. (2006) · CRC Press eBooks · doi:10.1201/9781420015768 · Cited by 1,915
Laboratory of Biomechanics and Biomedical Engineering, D. O. M. E., Katsikogianni, M., & Missirlis, Y. (2004) · European Cells and Materials · doi:10.22203/ecm.v008a05 · Cited by 1,178
Interfacial Forces in Aqueous Media
Visser, H. (1995) · Powder Technology · doi:10.1016/0032-5910(95)90005-5 · Cited by 880
Antibacterial coatings on titanium implants
Zhao, L., Chu, P. K., Zhang, Y., & Wu, Z. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31463 · Cited by 866
The interaction of cells and bacteria with surfaces structured at the nanometre scale
Anselme, K., Davidson, P., Popa, A. M., Giazzon, M., Liley, M., & Ploux, L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.001 · Cited by 827
The future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779
The relationship between the nanostructure of titanium surfaces and bacterial attachment
Puckett, S. D., Taylor, E., Raimondo, T., & Webster, T. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.081 · Cited by 683
Bacterial adhesion to glass and metal-oxide surfaces
Li, B., & Logan, B. E. (2004) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2004.05.006 · Cited by 594
Electric double layer interactions in bacterial adhesion to surfaces
Poortinga, A. T., Bos, R., Norde, W., & Busscher, H. J. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00032-8 · Cited by 485
The influence of nano-scale surface roughness on bacterial adhesion to ultrafine-grained titanium
Truong, V. K., Lapovok, R., Estrin, Y. S., Rundell, S., Wang, J. Y., Fluke, C. J., Crawford, R. J., & Ivanova, E. P. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.071 · Cited by 438
Bacterial adhesion to surface hydrophilic and hydrophobic contact lenses
Bruinsma, G. M., van der Mei, H. C., & Busscher, H. J. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00159-4 · Cited by 417
Surface topographical factors influencing bacterial attachment
Crawford, R. J., Webb, H. K., Truong, V. K., Hasan, J., & Ivanova, E. P. (2012) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2012.06.015 · Cited by 384
Infections from biomaterials and implants: a race for the surface.
Gristina, A. G., Naylor, P., & Myrvik, Q. N. (1989) · PubMed · Cited by 309
Forces involved in bacterial adhesion to hydrophilic and hydrophobic surfaces
Boks, N. P., Norde, W., van der Mei, H. C., & Busscher, H. J. (2008) · Microbiology · doi:10.1099/mic.0.2008/018622-0 · Cited by 289
Differential response of Staphylococci and osteoblasts to varying titanium surface roughness
Wu, Y., Zitelli, J. P., TenHuisen, K. S., Yu, X., & Libera, M. R. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.10.001 · Cited by 248
Zhang, F., Zhang, Z., Zhu, X., Kang, E.-T., & Neoh, K.-G. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.043 · Cited by 212
Impact of Nanoscale Roughness of Titanium Thin Film Surfaces on Bacterial Retention
Ivanova, E. P., Truong, V. K., Wang, J. Y., Berndt, C. C., Jones, R. T., Yusuf, I. I., Peake, I., Schmidt, H. W., Fluke, C., Barnes, D., et al. (2010) · Langmuir · doi:10.1021/la902623c · Cited by 205
Pathogenesis and prevention of biomaterial centered infections
Gottenbos, B., Busscher, H. J., van der Mei, H. C., & Nieuwenhuis, P. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1016175502756 · Cited by 152
Gallardo-Moreno, A. M., Pacha‐Olivenza, M. A., Saldaña, L., Pérez-Giraldo, C., Bruque, J. M., Vilaboa, N. E., & González-Martín, M. L. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.07.028 · Cited by 148
Inhibition of Bacterial Adhesion on Medical Devices
Rodrigues, L. R. (2011) · Advances in experimental medicine and biology · doi:10.1007/978-94-007-0940-9_22 · Cited by 147
An Antibacterial Surface on Dental Implants, Based on the Photocatalytic Bactericidal Effect
Suketa, N., Sawase, T., Kitaura, H., Naito, M., Baba, K., Nakayama, K., Wennerberg, A., & Atsuta, M. (2005) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2005.tb00053.x · Cited by 113
Photoinduced properties of nanocrystalline TiO2-anatase coating on Ti-based bone implants
Lorenzetti, M., Biglino, D., Novak, S., & Kobe, S. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.01.029 · Cited by 37
Self-citationInfections of Orthopaedic Implants and Devices
Brady, R. A., Calhoun, J. H., Leid, J. G., & Shirtliff, M. E. (2008) · Springer series on biofilms · doi:10.1007/978-3-540-68119-9_2 · Cited by 30
Cited by
Zheng, S., Bawazir, M., Dhall, A., Kim, H.-E., He, L., Heo, J., & Hwang, G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.643722 · Cited by 872
Surface characteristics influencing bacterial adhesion to polymeric substrates
Yuan, Y., Hays, M. P., Hardwidge, P. R., & Kim, J. (2017) · RSC Advances · doi:10.1039/c7ra01571b · Cited by 466
Jaggessar, A., Shahali, H., Mathew, A., & Yarlagadda, P. K. D. V. (2017) · Journal of Nanobiotechnology · doi:10.1186/s12951-017-0306-1 · Cited by 441
Antibacterial titanium nano-patterned arrays inspired by dragonfly wings
Bhadra, C. M., Khanh Truong, V., Pham, V. T. H., Al Kobaisi, M., Seniutinas, G., Wang, J. Y., Juodkazis, S., Crawford, R. J., & Ivanova, E. P. (2015) · Scientific Reports · doi:10.1038/srep16817 · Cited by 308
Towards Laser-Textured Antibacterial Surfaces
Lutey, A. H. A., Gemini, L., Romoli, L., Lazzini, G., Fuso, F., Faucon, M., & Kling, R. (2018) · Scientific Reports · doi:10.1038/s41598-018-28454-2 · Cited by 292
Metadata
- Authors
- Lorenzetti, M., Dogša, I., Stošicki, T., Stopar, D., Kalin, M., Kobe, S., & Novak, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-01-14
- Volume
- 7
- Issue
- 3
- Pages
- 1644-1651
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2317685136
- Cited by
- 365
- References
- 25
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.