Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 345

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Nanoparticulate X-ray Computed Tomography Contrast Agents: From Design Validation to in Vivo Applications

Liu, Yanlan, Ai, Kelong, Lu, Lehui·2012·Accounts of Chemical Research

Abstract

X-ray computed tomography (CT) is one of the most powerful noninvasive diagnostic imaging techniques in modern medicine. Nevertheless, the iodinated molecules used as CT contrast agents in the clinic have relatively short circulation times in vivo, which significantly restrict the applications of this technique in target-specific imaging and angiography. In addition, the use of these agents can present adverse. For example, an adult patient typically receives approximately 70 mL of iodinated agent (350 mg I/mL) because of iodine's low contrast efficacy. Rapid renal clearance of such a large dose of these agents may lead to serious adverse effects. Furthermore, some patients are hypersensitive to iodine. Therefore, biomedical researchers have invested tremendous efforts to address these issues. Over the past decade, advances in nanoscience have created new paradigms for imaging. The unique properties of nanomaterials, such as their prolonged circulating half-life, passive accumulation at the tumor sites, facile surface modification, and integration of multiple diverse functions into a single particle, make them advantageous for in vivo applications. However, research on the utilization of nanomaterials for CT imaging has lagged far behind their applications for other imaging techniques such as MRI and fluorescence imaging because of the challenges in the preparation of cost-effective nanoparticulate CT contrast agents with excellent biocompatibility, high contrast efficacy, long in vivo circulation time, and long-term colloidal stability in physiological environments. This Account reviews our recent work on the design and in vivo applications of nanoparticulate CT contrast agents. By optimizing the contrast elements in the nanoparticles according to the fundamental principles of X-ray imaging and by employing the surface engineering approaches that we and others have developed, we have synthesized several nanoparticulate CT contrast agents with excellent imaging performance. For example, a novel Yb-based nanoparticulate agent provides enhanced contrast efficacy compared to currently available CT contrast agents under normal operating conditions. To deal with special situations, we integrated both Ba and Yb with great differential in K-edge value into a single particle to yield the first example of binary contrast agents. This agent displays much higher contrast than iodinated agents at different voltages and is highly suited to diagnostic imaging of various patients. Because of their prolonged in vivo circulation time and extremely low toxicity, these agents can be used for angiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ar300150c

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 345

Metadata

Authors
Liu, Y., Ai, K., & Lu, L.
Venue
Accounts of Chemical Research
Published
2012-09-05
Volume
45
Issue
10
Pages
1817-1827
ISSN
  • 0001-4842 (ISSN-L)
  • 1520-4898
OpenAlex
W2020638337
Cited by
345
References
40
FWCI
13.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nanoparticulate X-ray Computed Tomography Contrast Agents: From Design Validation to in Vivo Applications. https://app.cochat.ai/papers/10.1021/ar300150c
The paper
Liu, Y., Ai, K., & Lu, L. (2012). Nanoparticulate X-ray Computed Tomography Contrast Agents: From Design Validation to in Vivo Applications. Accounts of Chemical Research. https://doi.org/10.1021/ar300150c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.