The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Electrochemistry in Diabetes Management
Abstract
Diabetes devastates lives and burdens society. Hypoglycemic (low glucose) episodes cause blackouts, and severe ones are life-threatening. Periods of hyperglycemia (high glucose) cause circulatory disease, stroke, amputations, blindness, kidney failure and nerve degeneration. In this Account, we describe the founding of TheraSense, now a major part of Abbott Diabetes Care, and the development of two products that have improved the lives of people with diabetes. The first, a virtually painless microcoulometer (300 nL volume), the FreeStyle blood glucose monitoring system, was approved by the FDA and became available in 2000. In 2009, this system was used in more than one billion blood assays. The second, the enzyme-wiring based, subcutaneously-implanted FreeStyle Navigator continuous glucose monitoring system, was approved by the FDA and became available in the United States in 2008. The strips of the FreeStyle blood glucose monitoring system comprise a printed parallel plate coulometer, with a 50 microm gap between two facing printed electrodes, a carbon electrode and a Ag/AgCl electrode. The volume of blood between the facing plates is accurately controlled. The glucose is electrooxidized through catalysis by a glucose dehydrogenase (GDH) and an Os(2+/3+) redox mediator, which is reduced by the glucose-reduced enzyme and is electrooxidized on the carbon electrode. Initially the system used pyrroloquinoline quinone (PQQ)-dependent GDH but now uses flavin adenine dinucleotide (FAD)-dependent GDH. Because the facing electrodes are separated by such a small distance, shuttling of electrons by the redox couple could interfere with the coulometric assay. However, the Os(2+/3+) redox mediator is selected to have a substantially negative formal potential, between 0.0 and -0.2 V, versus that of the facing Ag/AgCl electrode. This makes the flow of a shuttling current between the two electrodes virtually impossible because the oxidized Os(3+) complex cannot be appreciably reduced at the more positively poised Ag/AgCl electrode. The FreeStyle Navigator continuous glucose monitoring system uses a subcutaneously implanted miniature plastic sensor connected to a transmitter to measure glycemia amperometrically and sends the information to a PDA-like device every minute. The sensor consists of a narrow (0.6 mm wide) plastic substrate on which carbon-working, Ag/AgCl reference, and carbon counter electrodes are printed in a stacked geometry. The active wired enzyme sensing layer covers only about 0.1 mm(2) of the working electrode and is overlaid by a flux-limiting membrane. It resides at about 5 mm depth in the subcutaneous adipose tissue and monitors glucose concentrations over the range 20-500 mg/dL. Its core component, a miniature, disposable, amperometric glucose sensor, has an electrooxidation catalyst made from a crosslinked adduct of glucose oxidase (GOx) and a GOx wiring redox hydrogel containing a polymer-bound Os(2+/3+) complex. Because of the selectivity of the catalyst for glucose, very little current flows in the absence of glucose. That feature, either alone or in combination with other features of the sensor, facilitates the one-point calibration of the system. The sensor is implanted subcutaneously and replaced by the patient after 5 days use with minimal pain. The wearer does not feel its presence under the skin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationFerrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E. V., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,646
Electrical connection of enzyme redox centers to electrodes
Heller, A. (1992) · The Journal of Physical Chemistry · doi:10.1021/j100188a007 · Cited by 603
Self-citationDegani, Y., & Heller, A. (1987) · The Journal of Physical Chemistry · doi:10.1021/j100290a001 · Cited by 574
Self-citationCross-linked redox gels containing glucose oxidase for amperometric biosensor applications
Gregg, B. A., & Heller, A. (1990) · Analytical Chemistry · doi:10.1021/ac00202a007 · Cited by 479
Self-citationMao, F., Mano, N., & Heller, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja029510e · Cited by 409
Self-citationOhara, T. J., Rajagopalan, R., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00087a008 · Cited by 379
Self-citationDegani, Y., & Heller, A. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00188a091 · Cited by 354
Self-citationElectron-conducting redox hydrogels: design, characteristics and synthesis
Heller, A. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.09.018 · Cited by 352
Self-citationOhara, T. J., Rajagopalan, R., & Heller, A. (1993) · Analytical Chemistry · doi:10.1021/ac00071a031 · Cited by 281
Self-citationGregg, B. A., & Heller, A. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a046 · Cited by 275
Self-citationImplanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Self-citationFeldman, B., Brazg, R., Schwartz, S., & Weinstein, R. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322526978 · Cited by 184
Self-citationHigh current density "wired" quinoprotein glucose dehydrogenase electrode
Ye, L., Haemmerle, M., Olsthoorn, A. J. J., Schuhmann, W., Schmidt, H. L., Duine, J. A., & Heller, A. (1993) · Analytical Chemistry · doi:10.1021/ac00051a008 · Cited by 175
Self-citationQuinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Self-citationPishko, M. V., Michael, A. C., & Heller, A. (1991) · Analytical Chemistry · doi:10.1021/ac00020a014 · Cited by 148
Self-citationCsöregi, E., Schmidtke, D. W., & Heller, A. (1995) · Analytical Chemistry · doi:10.1021/ac00103a015 · Cited by 129
Self-citationBiocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126
Self-citationOn the parameters affecting the characteristics of the “wired” glucose oxidase anode
Mano, N., Mao, F., & Heller, A. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.08.014 · Cited by 120
Self-citationSchmidtke, D. W., Freeland, A. C., Heller, A., & Bonnecaze, R. T. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.1.294 · Cited by 120
Self-citationElimination of electrooxidizable interferant-produced currents in amperometric biosensors
Maidan, R., & Heller, A. (1992) · Analytical Chemistry · doi:10.1021/ac00047a003 · Cited by 117
Self-citationElectron diffusion coefficients in hydrogels formed of cross-linked redox polymers
Aoki, A., & Heller, A. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100144a019 · Cited by 112
Self-citationCsöregi, E., Quinn, C. P., Schmidtke, D. W., Lindquist, S., Pishko, M. V., Ye, L., Katakis, I., Hubbell, J. A., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00091a022 · Cited by 110
Self-citationTaylor, C., Kenausis, G., Katakis, I., & Heller, A. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04080-8 · Cited by 100
Self-citationAoki, A., Rajagopalan, R., & Heller, A. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100014a034 · Cited by 91
Self-citationFreeStyle ™ : A Small-Volume Electrochemical Glucose Sensor for Home Blood Glucose Testing
Feldman, B., McGarraugh, G., Heller, A., Bohannon, N. J. V., Skyler, J. S., DeLeeuw, E. R., & Clarke, D. H. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050025177 · Cited by 70
Self-citationSchmidtke, D. W., & Heller, A. (1998) · Analytical Chemistry · doi:10.1021/ac970932u · Cited by 65
Self-citationMcGarraugh, G. V., & Bergenstal, R. M. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0047 · Cited by 61
Wagner, J. G., Schmidtke, D. W., Quinn, C. P., Fleming, T. F., Bernacky, B. J., & Heller, A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.11.6379 · Cited by 51
Self-citationDanne, T., de Valk, H. W., Kracht, T., Walte, K., Geldmacher, R., Sölter, L., Berge, W. V. D., Welsh, Z., Bugler, J., Lange, K., et al. (2009) · Diabetologia · doi:10.1007/s00125-009-1408-6 · Cited by 37
Pishko, M. V., Katakis, I., Lindquist, S., Ye, L., Gregg, B. A., & Heller, A. (1990) · Angewandte Chemie · doi:10.1002/ange.19901020135 · Cited by 19
Self-citationThe ExacTech blood glucose testing system
Kyvik, K. O., Traulsen, J., Reinholdt, B., & Frøland, A. (1990) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(90)90085-8 · Cited by 14
Research works printed but not linked: 2
- Gregg B. A., 1991, J. Phys. Chem., 95, 5976, 10.1021/j100168a047 · doi:10.1021/j100168a047
- Quinn C. P., 1995, Am. J. Physiol., 269, E155
Cited by
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Advances in non-enzymatic glucose sensors based on metal oxides
Zhu, H., Li, L., Zhou, W., Shao, Z., & Chen, X. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb02037b · Cited by 473
Advances in carbon nanotube based electrochemical sensors for bioanalytical applications
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.10.002 · Cited by 448
Metadata
- Authors
- Heller, A., & Feldman, B.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-04-12
- Volume
- 43
- Issue
- 7
- Pages
- 963-973
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2081832007
- Cited by
- 255
- References
- 34
- FWCI
- 16.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.