The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Metal-Based Turn-On Fluorescent Probes for Sensing Nitric Oxide
Abstract
Nitric oxide, a reactive free radical, regulates a variety of biological processes. The absence of tools to detect NO directly, rapidly, specifically, and selectively motivated us to synthesize metal-based fluorescent probes to visualize the presence of NO. We prepared and investigated Co(II), Fe(II), Ru(II), Rh(II), and Cu(II) complexes as turn-on fluorescent NO sensors. Our exploration has provided insight into how the interaction of transition-metal centers with nitric oxide can be utilized for NO sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wood, J., & Garthwaite, J. (1994) · Neuropharmacology · doi:10.1016/0028-3908(94)90022-1 · Cited by 529
Nagano, T., & Yoshimura, T. (2002) · Chemical Reviews · doi:10.1021/cr010152s · Cited by 414
Murad, F. (1999) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19990712)38:13/14<1856::aid-anie1856>3.0.co;2-d · Cited by 381
Dirhodium Tetracarboxylate Scaffolds as Reversible Fluorescence-Based Nitric Oxide Sensors
Hilderbrand, S. A., Lim, M. H., & Lippard, S. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja038471j · Cited by 144
Self-citationSynthesis and Structural Characterization of Several Ruthenium Porphyrin Nitrosyl Complexes
Miranda, K. M., Bu, X., Lorković, I. M., & Ford, P. C. (1997) · Inorganic Chemistry · doi:10.1021/ic970065b · Cited by 122
Tsuge, K., DeRosa, F., Lim, M. D., & Ford, P. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049444b · Cited by 110
Self-citationElectrochemical methods for detection of nitric oxide
Christodoulou, D., Kudo, S., Cook, J. A., Krishna, M. C., Miles, A. M., Grisham, M. B., Murugesan, R., Ford, P. C., & Wink, D. A. (1996) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(96)68010-0 · Cited by 61
Pentacoordinate Cobalt(III) Thiolate and Nitrosyl Tropocoronand Compounds
Franz, K. J., Doerrer, L. H., Spingler, B., & Lippard, S. J. (2001) · Inorganic Chemistry · doi:10.1021/ic010181l · Cited by 48
Self-citationNitric Oxide: Biochemistry, Physiology, and Pathophysiology
Conner, E. M., & Grisham, M. B. (1995) · Methods · doi:10.1006/meth.1995.1002 · Cited by 43
Katayama, Y., Takahashi, S., & Maeda, M. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00089-0 · Cited by 36
Cited by
Aggregation-induced emission: phenomenon, mechanism and applications
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Communications · doi:10.1039/b904665h · Cited by 4,115
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Bright Ideas for Chemical Biology
Lavis, L. D., & Raines, R. T. (2008) · ACS Chemical Biology · doi:10.1021/cb700248m · Cited by 1,290
Cysteine-Mediated Redox Signaling: Chemistry, Biology, and Tools for Discovery
Paulsen, C. E., & Carroll, K. S. (2013) · Chemical Reviews · doi:10.1021/cr300163e · Cited by 1,278
Lanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
Application of Metal Coordination Chemistry To Explore and Manipulate Cell Biology
Haas, K. L., & Franz, K. J. (2009) · Chemical Reviews · doi:10.1021/cr900134a · Cited by 984
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Wardman, P. (2007) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.06.026 · Cited by 864
Wang, M., Zhang, G., Zhang, D., Zhu, D., & Tang, B. Z. (2010) · Journal of Materials Chemistry · doi:10.1039/b921610c · Cited by 852
Dickinson, B. C., Huynh, C., & Chang, C. J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1014103 · Cited by 515
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
Chemically diverse small molecule fluorescent chemosensors for copper ion
Sivaraman, G., Iniya, M., Anand, T., Kotla, N. G., Sunnapu, O., Singaravadivel, S., Gulyani, A., & Chellappa, D. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.020 · Cited by 391
Analytical Chemistry of Nitric Oxide
Hetrick, E. M., & Schoenfisch, M. H. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155146 · Cited by 314
Metadata
- Authors
- Lim, M. H., & Lippard, S. J.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-04
- Volume
- 40
- Issue
- 1
- Pages
- 41-51
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2131216948
- Cited by
- 262
- References
- 10
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.