A Biomimetic pH-Responsive Polymer Directs Endosomal Release and Intracellular Delivery of an Endocytosed Antibody Complex
The DOI matches its Crossref record.
Abstract
Poly(propylacrylic acid) (PPAAc) is a synthetic pH-responsive polymer that has been shown to disrupt cell membranes at low pH values typical of the endosome, but not at physiological pH, suggesting its use as an endosomal-releasing agent [Murthy et al. J. Controlled Release 61, 137-43]. We have constructed an antibody-targeted biotherapeutic model to investigate whether PPAAc can enhance intracellular trafficking of proteins to the cytoplasm. A ternary complex composed of a biotinylated anti-CD3 antibody, streptavidin, and biotinylated PPAAc was fluorescently labeled, and its intracellular fate was analyzed by confocal microscopy, flow cytometry, and quantitative western blotting of cell fractionates. The 64.1 anti-CD3 antibody was previously shown to direct receptor-mediated endocytosis in the Jurkat T-cell lymphoma cell line and was rapidly trafficked from the endosome to the lysosomal compartment. The antibody-streptavidin complex was also rapidly internalized to the endosomal/lysosomal compartment and retained there, as evidenced by punctate regions of fluorescence observed by confocal fluorescence microscopy. In samples containing the ternary complex of antibody, streptavidin, and PPAAc-biotin, diffuse fluorescence in the cytoplasm was observed, indicating that PPAAc enhanced translocation to the cytoplasm. This was confirmed by western blotting analysis of the isolated cytoplasm. Flow cytometry results demonstrated that neither streptavidin nor PPAAc caused nonspecific uptake of the complex, nor did they inhibit antibody-mediated endocytosis. The striking enhancement of protein delivery to the cytoplasm by complexed PPAAc suggests that this polymer could provide a new delivery agent for therapeutic, vaccine, and diagnostics development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polymers for Drug Delivery Systems
Liechty, W. B., Kryscio, D. R., Slaughter, B. V., & Peppas, N. A. (2010) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-073009-100847 · Cited by 1,608
New directions in thermoresponsive polymers
Roy, D., Brooks, W. L. A., & Sumerlin, B. S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35499g · Cited by 1,311
Stimuli-responsive molecular brushes
Lee, H.-I., Pietrasik, J., Sheiko, S. S., & Matyjaszewski, K. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.11.002 · Cited by 652
Smart hybrid materials by conjugation of responsive polymers to biomacromolecules
Cobo, I., Li, M., Sumerlin, B. S., & Perrier, S. (2015) · Nature Materials · doi:10.1038/nmat4106 · Cited by 574
Tailoring nanocarriers for intracellular protein delivery
Gu, Z., Biswas, A., Zhao, M., & Tang, Y. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00227e · Cited by 543
Metadata
- Authors
- Lackey, C. A., Press, O. W., Hoffman, A. S., & Stayton, P. S.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-07-25
- Volume
- 13
- Issue
- 5
- Pages
- 996-1001
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W1993923839
- Cited by
- 142
- References
- 0
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Biomimetic pH-Responsive Polymer Directs Endosomal Release and Intracellular Delivery of an Endocytosed Antibody Complex. https://app.cochat.ai/papers/10.1021/bc010053l
- The paper
- Lackey, C. A., Press, O. W., Hoffman, A. S., & Stayton, P. S. (2002). A Biomimetic pH-Responsive Polymer Directs Endosomal Release and Intracellular Delivery of an Endocytosed Antibody Complex. Bioconjugate Chemistry. https://doi.org/10.1021/bc010053l
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.