The DOI matches its Crossref record.
Cross-Linking Exogenous Bifunctional Peptides into Fibrin Gels with Factor XIIIa
Open accessAbstract
Bi-domain peptides with a factor XIIIa substrate in one domain and a bioactive peptide in another domain were covalently incorporated into fibrin gels during coagulation through the action of the transglutaminase factor XIIIa. The cross-linking characteristics were determined for two bi-domain peptides with factor XIIIa substrates based on fibrinogen, dYRGDTIGEGQQHHLGG-NH2, and dLRGDGAKDV-NH2, as well as one bi-domain peptide with a substrate sequence based on alpha2-plasmin inhibitor, dLNQEQVSPLRGD-NH2, and another with a nonbiological, oligolysine substrate, dLRGDKKKKG-NH2 (substrate domains in italic). Each of these peptides was able to cross-link into the fibrin gels during coagulation, with the peptide containing the factor XIIIa substrate based on alpha2-plasmin inhibitor being incorporated at levels in excess of 8 mol/mol fibrinogen. The structural characteristics of these peptide-modified gels proved to be the same as those for a native fibrin gel. The bioactivity of the incorporated active factors was tested in a neuronal culture model with day 8 chicken dorsal root ganglia using two bioactive sequences, RGD and DGEA, and one inactive control sequence, RDG. Each of these peptides influenced the extension of neurites from the ganglia as expected, indicating that the incorporated factors retained their activity. With the use of soluble competitive inhibitors, it was shown that this effect was due to the covalently incorporated peptides. Through exploiting the role of factor XIIIa in coagulation, we have developed a method by which to impart the character of nonfibrin proteins, such as extracellular matrix proteins, to fibrin, a biological material with many potential therapeutic and academic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
RGD modified polymers: biomaterials for stimulated cell adhesion and beyond
Hersel, U., Dahmen, C., & Kessler, H. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00343-0 · Cited by 2,582
Biomimetic materials for tissue engineering
Shin, H., Jo, S., & Mikos, A. G. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00339-9 · Cited by 1,612
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Synthetic alternatives to Matrigel
Aisenbrey, E. A., & Murphy, W. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0199-8 · Cited by 1,016
Fibrin: A versatile scaffold for tissue engineering applications
Ahmed, T. A. E., Dare, E. V., & Hincke, M. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0435 · Cited by 994
Yi, H., Wu, L.-Q., Bentley, W. E., Ghodssi, R., Rubloff, G. W., Culver, J. N., & Payne, G. F. (2005) · Biomacromolecules · doi:10.1021/bm050410l · Cited by 759
Martino, M. M., Briquez, P. S., Ranga, A., Lutolf, M. P., & Hubbell, J. A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221602110 · Cited by 473
Self-citationHubbell, J. A. (1999) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)80021-4 · Cited by 473
Self-citationMartino, M. M., Tortelli, F., Mochizuki, M., Traub, S., Ben-David, D., Kuhn, G. A., Müller, R., Livne, E., Eming, S. A., & Hubbell, J. A. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002614 · Cited by 459
Self-citationBio-printing of collagen and VEGF-releasing fibrin gel scaffolds for neural stem cell culture
Lee, Y.-B., Polio, S., Lee, W., Dai, G., Menon, L., Carroll, R. S., & Yoo, S.-S. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2010.02.014 · Cited by 388
Materials as morphogenetic guides in tissue engineering
Hubbell, J. A. (2003) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2003.09.004 · Cited by 379
Self-citationHydrogels for tissue engineering and regenerative medicine
Hunt, J. A., Chen, R., van Veen, T., & Bryan, N. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00775a · Cited by 377
Martino, M. M., Mochizuki, M., Rothenfluh, D. A., Rempel, S. A., Hubbell, J. A., & Barker, T. H. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.047 · Cited by 324
Self-citationMartino, M. M., & Hubbell, J. A. (2010) · The FASEB Journal · doi:10.1096/fj.09-151282 · Cited by 316
Self-citationThe effect of hydrogel charge density on cell attachment
Schneider, G. B., English, A., Abraham, M., Zaharias, R., Stanford, C., & Keller, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.084 · Cited by 314
Macroscale delivery systems for molecular and cellular payloads
Kearney, C. J., & Mooney, D. J. (2013) · Nature Materials · doi:10.1038/nmat3758 · Cited by 301
Lee, F., Chung, J. E., & Kurisawa, M. (2008) · Soft Matter · doi:10.1039/b719557e · Cited by 300
Growth of Epithelial Organoids in a Defined Hydrogel
Broguiere, N., Isenmann, L., Hirt, C., Ringel, T., Placzek, S., Cavalli, E., Ringnalda, F., Villiger, L., Züllig, R., Lehmann, R., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801621 · Cited by 282
Extracellular matrix-inspired growth factor delivery systems for bone regeneration
Martino, M. M., Briquez, P. S., Maruyama, K., & Hubbell, J. A. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.04.007 · Cited by 261
Self-citationPolymeric Systems for Bioprinting
Bedell, M. L., Navara, A. M., Du, Y., Zhang, S., & Mikos, A. G. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00834 · Cited by 258
Fibrin as a cell carrier in cardiovascular tissue engineering applications
Mol, A., van Lieshout, M. I., Dam-de Veen, C. G., Neuenschwander, S., Hoerstrup, S. P., Baaijens, F. P. T., & Bouten, C. V. C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.007 · Cited by 257
3D bioprinting of structural proteins
Włodarczyk-Biegun, M. K., & del Campo, A. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.019 · Cited by 185
The promotion of endothelial cell attachment and spreading using FNIII10 fused to VEGF-A165
Traub, S., Morgner, J., Martino, M. M., Höning, S., Swartz, M. A., Wickström, S. A., Hubbell, J. A., & Eming, S. A. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.050 · Cited by 42
Self-citationGiannotti, S., Trombi, L., Bottai, V., Ghilardi, M., D'Alessandro, D., Danti, S., Dell'Osso, G., Guido, G., & Petrini, M. (2013) · PLoS ONE · doi:10.1371/annotation/e4403abb-b80e-43c5-be74-1bdb2c899d1c · Cited by 12
Metadata
- Authors
- Schense, J. C., & Hubbell, J. A.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-12-08
- Volume
- 10
- Issue
- 1
- Pages
- 75-81
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2032717928
- Cited by
- 308
- References
- 0
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.