The DOI matches its Crossref record.
Preparation of a Cathepsin D Sensitive Near-Infrared Fluorescence Probe for Imaging
Abstract
A variety of proteases are overexpressed or activated during pathogenesis and represent important targets for therapeutic drugs. We have previously shown that optical imaging probes sensitive in the near-infrared fluorescence (NIRF) spectrum can be used for in vivo imaging of enzyme activity. In the current study, we show that these probes can be designed with specificity for specific enzymes, for example, cathepsin D which is known to be overexpressed in many tumors. A NIR cyanine fluorochrome served as the optical reporter and was attached to the amino terminal of an 11 amino acid peptide sequence with specificity for cathepsin D. The peptides were subsequently attached to a synthetic graft copolymer for efficient tumoral delivery. The close spatial proximity of the multiple fluorochromes resulted in quenching of fluorescence in the bound state. A 350-fold signal amplification was observed post cleavage during in vitro testing. Cell culture experiments using a rodent tumor cell line stably transfected with human cathepsin D confirmed enzyme specific activation within cells. This sequence but not a scrambled control sequence showed enzyme specificity in vitro. We conclude that activatable NIRF optical probes can be synthesized to potentially probe for specific enzymes in living organisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Self-citationAdvances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870
Inflammation in Atherosclerosis: Transition From Theory to Practice
Libby, P., Okamoto, Y., Rocha, V. Z., & Folco, E. (2010) · Circulation Journal · doi:10.1253/circj.cj-09-0706 · Cited by 799
In vivo molecular target assessment of matrix metalloproteinase inhibition
Bremer, C., Tung, C.-H., & Weissleder, R. (2001) · Nature Medicine · doi:10.1038/89126 · Cited by 726
Self-citationTargeted zwitterionic near-infrared fluorophores for improved optical imaging
Choi, H. S., Gibbs, S. L., Lee, J. H., Kim, S. H., Ashitate, Y., Liu, F., Hyun, H., Park, G., Xie, Y., Bae, S., et al. (2013) · Nature Biotechnology · doi:10.1038/nbt.2468 · Cited by 560
New Generation of Multifunctional Nanoparticles for Cancer Imaging and Therapy
Park, K., Lee, S., Kang, E., Kim, K., Choi, K., & Kwon, I. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801655 · Cited by 432
Kobayashi, H., & Choyke, P. L. (2011) · Accounts of Chemical Research · doi:10.1021/ar1000633 · Cited by 416
Nagaya, T., Nakamura, Y. A., Choyke, P. L., & Kobayashi, H. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00314 · Cited by 398
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Metadata
- Authors
- Tung, C.-H., Bredow, S., Mahmood, U., & Weissleder, R.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-09-01
- Volume
- 10
- Issue
- 5
- Pages
- 892-896
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W1979917813
- Cited by
- 212
- References
- 0
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.