The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Interactions of Indocyanine Green and Lipid in Enhancing Near-Infrared Fluorescence Properties: The Basis for Near-Infrared Imaging in Vivo
Open accessAbstract
Indocyanine green (ICG) is a near-infrared (NIR) contrast agent commonly used for in vivo cardiovascular and eye imaging. For medical diagnosis, ICG is limited by its aqueous instability, concentration-dependent aggregation, and rapid degradation. To overcome these limitations, scientists have formulated ICG in various liposomes, which are spherical lipid membrane vesicles with an aqueous core. Some encapsulate ICG, while others mix it with liposomes. There is no clear understanding of lipid-ICG interactions. Therefore, we investigated lipid-ICG interactions by fluorescence and photon correlation spectroscopy. These data were used to design stable and maximally fluorescent liposomal ICG nanoparticles for NIR optical imaging of the lymphatic system. We found that ICG binds to and is incorporated completely and stably into the lipid membrane. At a lipid:ICG molar ratio of 250:1, the maximal fluorescence intensity was detected. ICG incorporated into liposomes enhanced the fluorescence intensity that could be detected across 1.5 cm of muscle tissue, while free ICG only allowed 0.5 cm detection. When administered subcutaneously in mice, lipid-bound ICG in liposomes exhibited a higher intensity, NIR image resolution, and enhanced lymph node and lymphatic vessel visualization. It also reduced the level of fluorescence quenching due to light exposure and degradation in storage. Lipid-bound ICG could provide additional medical diagnostic value with NIR optical imaging for early intervention in cases of lymphatic abnormalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Indocyanine Green: Physicochemical Factors Affecting Its Fluorescencein Vivo
Mordon, S., Devoisselle, J. M., Soulie-Begu, S., & Desmettre, T. (1998) · Microvascular Research · doi:10.1006/mvre.1998.2068 · Cited by 268
Cited by
Carr, J. A., Franke, D., Caram, J. R., Perkinson, C. F., Saif, M., Askoxylakis, V., Datta, M., Fukumura, D., Jain, R. K., Bawendi, M. G., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718917115 · Cited by 721
Supramolecular cancer nanotheranostics
Zhou, J., Rao, L., Yu, G., Cook, T. R., Chen, X., & Huang, F. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00011f · Cited by 411
Shao, W., Chen, G., Kuzmin, A., Kutscher, H. L., Pliss, A., Ohulchanskyy, T. Y., & Prasad, P. N. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b08973 · Cited by 386
Yan, F., Wu, H., Liu, H., Deng, Z., Liu, H., Duan, W., Liu, X., & Zheng, H. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.12.050 · Cited by 254
Conceição, M., Mendonça, L., Nóbrega, C., Gomes, C., Costa, P., Hirai, H., Moreira, J. N., Lima, M. C., Manjunath, N., & Pereira de Almeida, L. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.12.021 · Cited by 117
Metadata
- Authors
- Kraft, J. C., & Ho, R. J. Y.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-02-17
- Volume
- 53
- Issue
- 8
- Pages
- 1275-1283
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2093865645
- Cited by
- 161
- References
- 1
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.