CoChat

Flip and Flop: A Molecular Determinant for AMPA Receptor Channel Opening

Pei, Weimin, Huang, Zhen, Wang, Congzhou, Han, Yan, Park, Jae Seon, Niu, Li · 2009 · Biochemistry
Cited by 71

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Alternative splicing in the extracellular ligand binding domain of the AMPA receptors generates two variants, i.e., flip and flop. The flop variant of the GluR2 AMPA receptor is known to desensitize faster than the flip counterpart, whereas the GluR1 flip and flop variants exhibit the same rate of desensitization. However, whether the alternative splicing affects the channel opening kinetic properties of these receptors is unknown. Using a laser-pulse photolysis technique, we have characterized the channel opening kinetic mechanism for the flip and flop channels of GluR1 and GluR2, respectively. We find that the flop variant of GluR2 opens the channel, following the binding of glutamate, with the same rate as the flip channel, but closes its channel more rapidly. The difference in the kinetic properties between the two receptor isoforms can be described by a model we proposed previously in which the channel closing rate, a measure of the stability of the open channel state, controls an apparent tendency of the channel to desensitize, most likely, through the closed channel state. Specifically, the flop sequence of GluR2 promotes the channel to close more rapidly and consequently to desensitize with a faster rate than the flip sequence. For GluR1, the alternative splicing does not seem to affect the channel opening kinetics, since the flip and flop variants of GluR1 have the same channel opening rate, and the same channel closing rate. As expected and indeed observed, the flop variant desensitizes with the same rate as the flip variant does. On the basis of these results, we hypothesize that the flip/flop sequence cassette of AMPA receptors, in a sequence-dependent manner, regulates the rate of the channel closing process, in the microsecond time domain, through which it further regulates the channel desensitization in the millisecond time region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bi8015907

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 71

Metadata

Authors
Pei, W., Huang, Z., Wang, C., Han, Y., Park, J. S., & Niu, L.
Venue
Biochemistry
Published
2009-04-06
Volume
48
Issue
17
Pages
3767-3777
ISSN
  • 0006-2960 (ISSN-L)
  • 1520-4995
OpenAlex
W2080066334
Cited by
71
References
6
FWCI
2.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flip and Flop: A Molecular Determinant for AMPA Receptor Channel Opening. https://app.cochat.ai/papers/10.1021/bi8015907
The paper
Pei, W., Huang, Z., Wang, C., Han, Y., Park, J. S., & Niu, L. (2009). Flip and Flop: A Molecular Determinant for AMPA Receptor Channel Opening. Biochemistry. https://doi.org/10.1021/bi8015907

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.