CoChat

Hybridization of Peptide Nucleic Acid

Ratilainen, Tommi, Holmén, Anders, Tuite, Eimer, Haaima, Gerald, Christensen, Leif, Nielsen, Peter E., Nordén, Bengt · 1998 · Biochemistry
Cited by 124

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The thermodynamics of hybridization and the conformations of decameric mixed purine-pyrimidine sequence PNA/PNA, PNA/DNA, and DNA/DNA duplexes have been studied using fluorescence energy transfer (FET), absorption hypochromicity (ABS), isothermal titration calorimetry (ITC), and circular dichroism (CD) techniques. The interchromophoric distances determined in the FET experiments on fluorescein- and rhodamine-labeled duplexes indicate that the solution structures of the duplexes are extended helices in agreement with available NMR (PNA/DNA) and crystal X-ray data (PNA/PNA). The melting thermodynamics of the duplexes was studied with both FET and ABS. The thermodynamic parameters obtained with ABS are in good agreement with the parameters from calorimetric measurements while FET detection of duplex melting gives in most cases more favorable free energies of hybridization. This discrepancy between FET and ABS detection is ascribed to the conjugated dyes which affect the stability of the duplexes substantially. Especially, the dianionic fluorescein attached via a flexible linker either to PNA or to DNA seems to be involved in an attractive interaction with the opposite dicationic lysine when hybridized to a PNA strand. This interaction leads to an increased thermal stability as manifested as a 3-4 degreesC increase of the melting temperature. For the PNA/DNA duplex where fluorescein is attached to the PNA strand, a large destabilization (DeltaTm = -12 degreesC) occurs relative to the unlabeled duplex, probably originating from electrostatic repulsion between the fluorescein and the negatively charged DNA backbone. In the case of the PNA/PNA duplex, the sense of helicity of the duplex is reversed upon conjugation of fluorescein via a flexible linker arm, but not when the fluorescein is attached without a linker to the PNA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bi9808722

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Ratilainen, T., Holmén, A., Tuite, E., Haaima, G., Christensen, L., Nielsen, P. E., & Nordén, B.
Venue
Biochemistry
Published
1998-08-14
Volume
37
Issue
35
Pages
12331-12342
ISSN
  • 0006-2960 (ISSN-L)
  • 1520-4995
OpenAlex
W1983172057
Cited by
124
References
1
FWCI
1.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.