Characterization and Biocompatibility Studies of Novel Humic Acids Based Films as Membrane Material for an Implantable Glucose Sensor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Multilayered films of humic acids (HAs) (naturally occurring biopolymers) were investigated as a potential semipermeable membrane for implantable glucose sensors. These films were grown using a layer-by-layer self-assembly process of HAs and oppositely charged ferric ions. The growth of these assemblies exhibited strong dependence on the pH and ionic strength of HAs solutions, which correlated with the degree of ionization of the carboxyl groups and neutralization-induced surface spreading. Quartz crystal microbalance (QCM) and ellipsometric studies have shown repeatable, stepwise increase in mass (as high as 5.63 microg/cm(2)) and in film thickness (ca. 24.3 nm per layer) for these assemblies. The permeability of glucose through these membranes can be regulated by varying the number of self-assembled HAs/Fe(3+) layers. Moreover, a 200 nm thick HAs/Fe(3+) film (in its hydrated state) had a shear modulus of about 80 MPa, implying stability upon implantation. These films were determined to be biocompatible since in vivo studies indicated only mild tissue reaction along with some neovascularization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vitro and in vivo mineralization of Nafion membrane used for implantable glucose sensors
Mercado, R. C., & Moussy, F. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00112-7 · Cited by 73
Self-citation
Cited by
Biomedical Applications of Layer‐by‐Layer Assembly: From Biomimetics to Tissue Engineering
Tang, Z., Wang, Y., Podsiadlo, P., & Kotov, N. A. (2006) · Advanced Materials · doi:10.1002/adma.200600113 · Cited by 1,302
Kleber, M., Sollins, P., & Sutton, R. (2007) · Biogeochemistry · doi:10.1007/s10533-007-9103-5 · Cited by 1,265
Marx, K. A. (2003) · Biomacromolecules · doi:10.1021/bm020116i · Cited by 1,143
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Introduction to nanocoatings produced by layer-by-layer (LbL) self-assembly
de Villiers, M. M., Otto, D. P., Strydom, S. J., & Lvov, Y. M. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.05.011 · Cited by 410
Metadata
- Authors
- Galeska, I., Hickey, T., Moussy, F., Kreutzer, D., & Papadimitrakopoulos, F.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-10-12
- Volume
- 2
- Issue
- 4
- Pages
- 1249-1255
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2034071670
- Cited by
- 61
- References
- 1
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.