The DOI matches its Crossref record.
Copolymerization of 2-Carboxyisopropylacrylamide with N-Isopropylacrylamide Accelerates Cell Detachment from Grafted Surfaces by Reducing Temperature
Abstract
Acrylic acid (AAc) has been utilized to introduce reactive carboxyl groups to a temperature-responsive polymer, poly(N-isopropylacrylamide) (PIPAAm). However, AAc introduction shifts the copolymer phase transition temperatures higher and dampens the steep homopolymer phase transition with increasing AAc content. We previously synthesized 2-carboxyisopropylacrylamide (CIPAAm) having both a similar side chain structure to IPAAm and a functional carboxylate group in order to overcome these shortcomings. In the present study, these copolymers, grafted onto cell culture plastic, were assessed for cell adhesion control using their phase transition. AAc introduction to PIPAAm-grafted surfaces resulted in excessive surface hydration and hindered cell spreading in culture at 37 degrees C. In contrast, CIPAAm-containing copolymer-grafted surfaces exhibited relatively weak hydrophobicity similar to both homopolymer PIPAAm-grafted surfaces as well as commercial ungrafted tissue culture polystyrene dish surfaces. Cells adhered and spread well on these surfaces at 37 degrees C in culture. As observed previously on PIPAAm-grafted surfaces, cells were spontaneously detached from the copolymer-grafted surfaces by reducing culture temperature. Cell detachment was accelerated on the CIPAAm copolymer-grafted surfaces compared to pure IPAAm surfaces, suggesting that hydrophilic carboxyl group microenvironment in the monomer and polymer is important to accelerate grafted surface hydration below the lower critical solution temperature, detaching cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stimuli-reponsive polymers and their bioconjugates
GIL, E., & HUDSON, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.08.003 · Cited by 2,385
Responsive polymers in controlled drug delivery
Bajpai, A. K., Shukla, S. K., Bhanu, S., & Kankane, S. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.005 · Cited by 1,391
Smart polymers: Physical forms and bioengineering applications
Kumar, A., Srivastava, A., Galaev, I. Y., & Mattiasson, B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.003 · Cited by 742
Moving from static to dynamic complexity in hydrogel design
Burdick, J. A., & Murphy, W. L. (2012) · Nature Communications · doi:10.1038/ncomms2271 · Cited by 561
Cole, M. A., Voelcker, N. H., Thissen, H., & Griesser, H. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.026 · Cited by 454
25th Anniversary Article: Designer Hydrogels for Cell Cultures: A Materials Selection Guide
Thiele, J., Ma, Y., Bruekers, S. M. C., Ma, S., & Huck, W. T. S. (2014) · Advanced Materials · doi:10.1002/adma.201302958 · Cited by 432
Drug delivery systems: Advanced technologies potentially applicable in personalized treatments
Coelho, J. F., Ferreira, P. C., Alves, P., Cordeiro, R., Fonseca, A. C., Góis, J. R., & Gil, M. H. (2010) · EPMA Journal · doi:10.1007/s13167-010-0001-x · Cited by 406
Nagase, K., Yamato, M., Kanazawa, H., & Okano, T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.026 · Cited by 393
Self-citationBioactive surfaces and biomaterials via atom transfer radical polymerization
Xu, F. J., Neoh, K. G., & Kang, E. T. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.04.005 · Cited by 368
Hydrogel as a bioactive material to regulate stem cell fate
Tsou, Y.-H., Khoneisser, J., Huang, P.-C., & Xu, X. (2016) · Bioactive Materials · doi:10.1016/j.bioactmat.2016.05.001 · Cited by 317
Elloumi‐Hannachi, I., Yamato, M., & Okano, T. (2010) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2009.02185.x · Cited by 271
Self-citationKikuchi, A., & Okano, T. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.08.026 · Cited by 264
Self-citationBiomimetic Smart Interface Materials for Biological Applications
Sun, T., & Qing, G. (2011) · Advanced Materials · doi:10.1002/adma.201004326 · Cited by 261
Xu, F.-J., Kang, E.-T., & Neoh, K.-G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.003 · Cited by 257
Temperature-responsive cell culture surfaces for regenerative medicine with cell sheet engineering
Yamato, M., Akiyama, Y., Kobayashi, J., Yang, J., Kikuchi, A., & Okano, T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.06.002 · Cited by 254
Self-citationChatterjee, S., Hui, P. C.-L., & Kan, C.-W. (2018) · Polymers · doi:10.3390/polym10050480 · Cited by 196
Chen, J.-K., & Chang, C.-J. (2014) · Materials · doi:10.3390/ma7020805 · Cited by 193
Metadata
- Authors
- Ebara, M., Yamato, M., Hirose, M., Aoyagi, T., Kikuchi, A., Sakai, K., & Okano, T.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-01-03
- Volume
- 4
- Issue
- 2
- Pages
- 344-349
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2051267609
- Cited by
- 176
- References
- 0
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.