The DOI matches its Crossref record.
Poly(N-isopropylacrylamide-co-propylacrylic acid) Copolymers That Respond Sharply to Temperature and pH
Abstract
Temperature- and pH-sensitive random copolymers of N-isopropylacrylamide (NIPAAm) and propylacrylic acid (PAA) were prepared using the reversible addition fragmentation chain transfer (RAFT) polymerization method. The lower critical solution temperatures (LCSTs) (or phase separation temperatures) of the NIPAAm-co-PAA copolymer solutions were measured by the cloud-point method. At slightly acidic conditions, the LCST decreased with increase in PAA content, which suggests that the hydrophobic propyl group of PAA has a greater influence on the LCST than the polar carboxylic acid group at those conditions. An increase of pH led to a significant increase in LCST of the copolymers due to the ionization of the -COOH group. The LCSTs were studied as a function of copolymer composition over the pH range from 5.0 to 7.0. Because the pK(a) of the polymers can be tuned to fall close to neutral pH, these polymer compositions can be designed to have phase transitions triggered near physiological pH or at slightly acidic pH values that fall within acidic gradients found in biology. The NIPAAm-co-PAA copolymers thus display tunable properties that could make them useful in a variety of molecular switching and drug delivery applications where responses to small pH changes are relevant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in controlled release formulations: Network design and mathematical modeling
Lin, C.-C., & Metters, A. T. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.004 · Cited by 1,768
Radical addition–fragmentation chemistry in polymer synthesis
Moad, G., Rizzardo, E., & Thang, S. H. (2008) · Polymer · doi:10.1016/j.polymer.2007.11.020 · Cited by 1,397
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Stimuli-responsive polymers: Biomedical applications and challenges for clinical translation
Hoffman, A. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.11.004 · Cited by 759
Self-citationMulti-Stimuli Sensitive Amphiphilic Block Copolymer Assemblies
Klaikherd, A., Nagamani, C., & Thayumanavan, S. (2009) · Journal of the American Chemical Society · doi:10.1021/ja809475a · Cited by 594
Metadata
- Authors
- Yin, X., Hoffman, A. S., & Stayton, P. S.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-04-22
- Volume
- 7
- Issue
- 5
- Pages
- 1381-1385
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1978584972
- Cited by
- 416
- References
- 0
- FWCI
- 13.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poly(N-isopropylacrylamide-co-propylacrylic acid) Copolymers That Respond Sharply to Temperature and pH. https://app.cochat.ai/papers/10.1021/bm0507812
- The paper
- Yin, X., Hoffman, A. S., & Stayton, P. S. (2006). Poly(N-isopropylacrylamide-co-propylacrylic acid) Copolymers That Respond Sharply to Temperature and pH. Biomacromolecules. https://doi.org/10.1021/bm0507812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.