The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Bio-Inspired Synthetic Nanovesicles for Glucose-Responsive Release of Insulin
Open accessAbstract
A new glucose-responsive formulation for self-regulated insulin delivery was constructed by packing insulin, glucose-specific enzymes into pH-sensitive polymersome-based nanovesicles assembled by a diblock copolymer. Glucose can passively transport across the bilayer membrane of the nanovesicle and be oxidized into gluconic acid by glucose oxidase, thereby causing a decrease in local pH. The acidic microenvironment causes the hydrolysis of the pH sensitive nanovesicle that in turn triggers the release of insulin in a glucose responsive fashion. In vitro studies validated that the release of insulin from nanovesicle was effectively correlated with the external glucose concentration. In vivo experiments, in which diabetic mice were subcutaneously administered with the nanovesicles, demonstrate that a single injection of the developed nanovesicle facilitated stabilization of the blood glucose levels in the normoglycemic state (<200 mg/dL) for up to 5 days.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediabetes: a high-risk state for diabetes development
Tabák, A. G., Herder, C., Rathmann, W., Brunner, E. J., & Kivimäki, M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60283-9 · Cited by 2,958
Giovannucci, E., Harlan, D. M., Archer, M. C., Bergenstal, R. M., Gapstur, S. M., Habel, L. A., Pollak, M., Regensteiner, J. G., & Yee, D. (2010) · Diabetes Care · doi:10.2337/dc10-0666 · Cited by 2,366
Discher, D. E., & Ahmed, F. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095838 · Cited by 844
Tailoring nanocarriers for intracellular protein delivery
Gu, Z., Biswas, A., Zhao, M., & Tang, Y. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00227e · Cited by 543
Self-citationHypoglycemia, functional brain failure, and brain death.
Cryer, P. E. (2007) · Journal of Clinical Investigation · doi:10.1172/jci31669 · Cited by 363
Cited by
Ye, Y., Wang, J., Hu, Q., Hochu, G. M., Xin, H., Wang, C., & Gu, Z. (2016) · ACS Nano · doi:10.1021/acsnano.6b04989 · Cited by 339
Self-citationMimicking the Cell: Bio-Inspired Functions of Supramolecular Assemblies
Tu, Y., Peng, F., Adawy, A., Men, Y., Abdelmohsen, L. K. E. A., & Wilson, D. A. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00344 · Cited by 316
Core–Shell Microneedle Gel for Self-Regulated Insulin Delivery
Wang, J., Ye, Y., Yu, J., Kahkoska, A. R., Zhang, X., Wang, C., Sun, W., Corder, R. D., Chen, Z., Khan, S. A., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b08152 · Cited by 299
Self-citation
Metadata
- Authors
- Tai, W., Mo, R., Di, J., Subramanian, V., Gu, X., Buse, J. B., & Gu, Z.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-09-30
- Volume
- 15
- Issue
- 10
- Pages
- 3495-3502
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2327103385
- Cited by
- 158
- References
- 5
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bio-Inspired Synthetic Nanovesicles for Glucose-Responsive Release of Insulin. https://app.cochat.ai/papers/10.1021/bm500364a
- The paper
- Tai, W., Mo, R., Di, J., Subramanian, V., Gu, X., Buse, J. B., & Gu, Z. (2014). Bio-Inspired Synthetic Nanovesicles for Glucose-Responsive Release of Insulin. Biomacromolecules. https://doi.org/10.1021/bm500364a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.