Nanofibrous Heparin and Heparin-Mimicking Multilayers as Highly Effective Endothelialization and Antithrombogenic Coatings
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Combining the advantages of the fibrous nanostructure of carbon nanotubes (CNTs) and the bioactivities of heparin/heparin-mimicking polyanions, functional nanofibrous heparin or heparin-mimicking multilayers were constructed on PVDF membrane with highly promoted endothelialization and antithrombogenic activities. Oxidized CNT (oCNT) was first functionalized with water-soluble chitosan (polycation), then enwrapped with heparin or a typical sulfonated heparin-mimicking polymers (poly(sodium 4-styrenesulfonate-co-sodium methacrylate)) to construct the multilayers. Then, the surface-deposited multilayers were constructed via electrostatic layer-by-layer assembly of the functionalized oCNTs. The scanning electron microscope and atom force microscope images confirmed that the coated multilayers exhibited nanofibrous and porous structure. The live/dead cell staining and cell viability assay results indicated that the coated nanofibrous multilayers had excellent compatibility with endothelial cells. The cell morphology observation further confirmed the promotion ability of surface endothelialization due to the coated heparin/heparin-mimicking multilayers. Further systematical evaluation on blood compatibility revealed that the surface heparin/heparin-mimicking multilayer-coated membranes also had significantly improved blood compatibility including restrained platelet adhesion and activation, prolonged blood clotting times, and inhibited activation of coagulation and complement factors. In summary, the proposed nanofibrous multilayers integrated endothelialization and antithrombogenic properties; meanwhile, the heparin-mimicking coating validated comparable performances as heparin coating. Herein, it is expected that the surface coating of nanofibrous multilayers, especially the facilely constructed heparin-mimicking coating, may have great application potential in biomedical fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Protein degradation and protection against misfolded or damaged proteins.
Goldberg, A. L. (2003) · Nature · doi:10.1038/nature02263 · Cited by 2,088
Mechanisms of Thrombus Formation
Furie, B., & Furie, B. C. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0801082 · Cited by 1,926
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Capila, I., & Linhardt, R. J. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020201)41:3<390::aid-anie390>3.0.co;2-b
Cited by
Liu, M., Zeng, G., Wang, K., Wan, Q., Tao, L., Zhang, X., & Wei, Y. (2016) · Nanoscale · doi:10.1039/c5nr09078d · Cited by 561
Cheng, C., Li, S., Thomas, A., Kotov, N. A., & Haag, R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00520 · Cited by 527
Self-citationZhang, W., Yu, X., Li, Y., Su, Z., Jandt, K. D., & Wei, G. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.12.001 · Cited by 189
Recent advances to accelerate re-endothelialization for vascular stents
Bedair, T. M., ElNaggar, M. A., Joung, Y. K., & Han, D. K. (2017) · Journal of Tissue Engineering · doi:10.1177/2041731417731546 · Cited by 89
Guo, G., Jin, L., Wu, B., He, H., Yang, F., Xu, L., Lei, Y., & Wang, Y. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.10.029 · Cited by 45
Metadata
- Authors
- Nie, C., Ma, L., Cheng, C., Deng, J., & Zhao, C.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-02-20
- Volume
- 16
- Issue
- 3
- Pages
- 992-1001
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2321875535
- Cited by
- 90
- References
- 5
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.