Biodegradable Fumarate-Based PolyHIPEs as Tissue Engineering Scaffolds
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PolyHIPEs show great promise as tissue engineering scaffolds due to the tremendous control of pore size and interconnectivity afforded by this technique. Highly porous, fully biodegradable scaffolds were prepared by polymerization of the continuous phase of high internal phase emulsions (HIPEs) containing the macromer poly(propylene fumarate) (PPF) and the cross-linker propylene fumarate diacrylate (PFDA). Toluene was used as a diluent to reduce the viscosity of the organic phase to enable HIPE formation. A range of polyHIPE scaffolds of different pore sizes and morphologies were generated by varying the diluent concentration (40-60 wt %), cross-linker concentration (25-75 wt %), and macromer molecular weight ( M n = 800-1000 g/mol). Although some formulations resulted in macroporous monoliths (pore diameter >500 microm), the majority of the polyHIPEs studied were rigid, microporous monoliths with average pore diameters in the range 10-300 microm. Gravimetric analysis confirmed the porosity of the microporous monoliths as 80-89% with most scaffolds above 84%. These studies demonstrate that emulsion templating can be used to generate rigid, biodegradable scaffolds with highly interconnected pores suitable for tissue engineering scaffolds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Injectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554
Self-citation
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Design and Preparation of Porous Polymers
Wu, D., Xu, F., Sun, B., Fu, R., He, H., & Matyjaszewski, K. (2012) · Chemical Reviews · doi:10.1021/cr200440z · Cited by 1,748
Functional Porous Polymers by Emulsion Templating: Recent Advances
Kimmins, S. D., & Cameron, N. R. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201001330 · Cited by 419
Self-citationA Review of Three-Dimensional Printing in Tissue Engineering
Sears, N. A., Seshadri, D. R., Dhavalikar, P. S., & Cosgriff-Hernandez, E. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0464 · Cited by 360
Aldemir Dikici, B., & Claeyssens, F. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00875 · Cited by 185
“, 2012a) or polypropylene fumarate (PPF) (Christenson et al., 2007; Moglia et al., 2011) HIPEs with the concentration of 1–5% w/v of the aqueous phase.”
BackgroundInfluentialCai, Z., Wan, Y., Becker, M. L., Long, Y.-Z., & Dean, D. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.038 · Cited by 133
Anderson, J. M., & Jiang, S. (2017) · The Immune Response to Implanted Materials and Devices · doi:10.1007/978-3-319-45433-7_2 · Cited by 55
Metadata
- Authors
- Christenson, E. M., Soofi, W., Holm, J. L., Cameron, N. R., & Mikos, A. G.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-11-03
- Volume
- 8
- Issue
- 12
- Pages
- 3806-3814
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2074255287
- Cited by
- 151
- References
- 1
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.