In Situ Fluorescence Cell Mass Measurements of Saccharomyces cerevisiae Using Cellular Tryptophan
The DOI matches its Crossref record.
Abstract
This work describes a new spectroscopic optical fiber/rod technique for in situ real time measurement of cell mass and product concentrations in bioreactors using intrinsic fluorescence. The variable excitation/emission wavelength capability of this sensor allows for species‐selective measurement during fermentations. Cell mass (tryptophan) and product concentrations (pyridoxine) have been measured during fermentations of Saccharomyces cerevisiae. The effects of varying substrate concentration and oxygen concentration on the observed cell mass signals are eliminated by direct measurement of cell mass, as opposed to indirect measurement schemes such as those using NADH fluorescence. The sensor is robust and able to undergo many cycles of in situ steam sterilization without degradation, and its fluorescence signal is linear with concentration for all species studied in this work. Tryptophan fluorescence from yeast is shown to be a better measure of cell mass than NADH fluorescence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Fluorescent signals emitted by proteins within cells [72] and vitamins [73] have proven effective in tracking microbial growth.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [72]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Real-time bioprocess monitoring
Vojinović, V., Cabral, J. M. S., & Fonseca, L. P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.07.059 · Cited by 221
In situ 2D fluorometry and chemometric monitoring of mammalian cell cultures
Teixeira, A. P., Portugal, C. A. M., Carinhas, N., Dias, J. M. L., Crespo, J. P., Alves, P. M., Carrondo, M. J. T., & Oliveira, R. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22125 · Cited by 90
Podrazký, O., Kuncová, G., Krasowska, A., & Sigler, K. (2003) · Folia Microbiologica · doi:10.1007/bf02930954 · Cited by 22
Mishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“Fluorescent signals emitted by proteins within cells [72] and vitamins [73] have proven effective in tracking microbial growth.”
Metadata
- Authors
- Horvath, J. J., Glazier, S. A., & Spangler, C. J.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 1993-11
- Volume
- 9
- Issue
- 6
- Pages
- 666-670
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2042885867
- Cited by
- 47
- References
- 0
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.