The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Incorporation of 3T3‐L1 Cells To Mimic Bioaccumulation in a Microscale Cell Culture Analog Device for Toxicity Studies
Abstract
Deficiencies in the early ADMET (absorption, distribution, metabolism, elimination, and toxicity) information on drug candidates extract a significant economic penalty on pharmaceutical firms. We have developed a microscale cell culture analog (μCCA) device that can potentially provide better, faster, and more efficient prediction of human and animal responses to a wide range of chemicals. The system described in this paper is a simple four‐chamber μCCA (“lung”–“liver”–“fat”–“other tissue”) designed on the basis of a physiologically based pharmacokinetics (PBPK) model of a rat. Cultures of L2, HepG2/C3A, and differentiated 3T3‐L1 adipocytes were selected to mimic the key functions of the lung, liver, and fat compartments, respectively. Here, we have demonstrated the application of the μCCA system to study bioaccumulation, distribution, and toxicity of selected compounds. Results from the bioaccumulation study reveal that hydrophobic compounds such as fluoranthene preferentially accumulated in the fat chamber. Only a small amount of fluoranthene was observed in the liver and lung chambers. In addition, the presence of the differentiated 3T3‐L1 adipocytes in the μCCA device significantly reduced naphthalene and naphthoquinone‐induced glutathione (GSH) depletion. These findings suggest the potential utilization of the μCCA system to assess ADMET characteristics of the compound of interest prior to animal or human trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of Quinones in Toxicology
Bolton, J. L., Trush, M. A., Penning, T. M., Dryhurst, G., & Monks, T. J. (2000) · Chemical Research in Toxicology · doi:10.1021/tx9902082 · Cited by 1,703
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Self-citationMicro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Metadata
- Authors
- Viravaidya, K., & Shuler, M. L.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2004-01
- Volume
- 20
- Issue
- 2
- Pages
- 590-597
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2136746348
- Cited by
- 184
- References
- 1
- FWCI
- 14.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.