The DOI matches its Crossref record.
Development of an in Vitro Multicellular Tumor Spheroid Model Using Microencapsulation and Its Application in Anticancer Drug Screening and Testing
Abstract
In this study, an in vitro multicellular tumor spheroid model was developed using microencapsulation, and the feasibility of using the microencapsulated multicellular tumor spheroid (MMTS) to test the effect of chemotherapeutic drugs was investigated. Human MCF-7 breast cancer cells were encapsulated in alginate-poly-l-lysine-alginate (APA) microcapsules, and a single multicellular spheroid 150 mum in diameter was formed in the microcapsule after 5 days of cultivation. The cell morphology, proliferation, and viability of the MMTS were characterized using phase contrast microscopy, BrdU-labeling, MTT stain, calcein AM/ED-2 stain, and H&E stain. It demonstrated that the MMTS was viable and that the proliferating cells were mainly localized to the periphery of the cell spheroid and the apoptotic cells were in the core. The MCF-7 MMTS was treated with mitomycin C (MC) at a concentration of 0.1, 1, or 10 times that of peak plasma concentration (ppc) for up to 72 h. The cytotoxicity was demonstrated clearly by the reduction in cell spheroid size and the decrease in cell viability. The MMTS was further used to screen the anticancer effect of chemotherapeutic drugs, treated with MC, adriamycin (ADM) and 5-fluorouracil (5-FU) at concentrations of 0.1, 1, and 10 ppc for 24, 48, and 72 h. MCF-7 monolayer culture was used as control. Similar to monolayer culture, the cell viability of MMTS was reduced after treatment with anticancer drugs. However, the inhibition rate of cell viability in MMTS was much lower than that in monolayer culture. The MMTS was more resistant to anticancer drugs than monolayer culture. The inhibition rates of cell viability were 68.1%, 45.1%, and 46.8% in MMTS and 95.1%, 86.8%, and 91.6% in monolayer culture treated with MC, ADM, and 5-FU at 10 ppc for 72 h, respectively. MC showed the strongest cytotoxicity in both MMTS and monolayer, followed by 5-FU and ADM. It demonstrated that the MMTS has the potential to be a rapid and valid in vitro model to screen chemotherapeutic drugs with a feature to mimic in vivo three-dimensional (3-D) cell growth pattern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Spherical Cancer Models in Tumor Biology
Weiswald, L.-B., Bellet, D., & Dangles-Marie, V. (2015) · Neoplasia · doi:10.1016/j.neo.2014.12.004 · Cited by 1,141
Three-dimensional in vitro tumor models for cancer research and drug evaluation
Xu, X., Farach-Carson, M. C., & Jia, X. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.07.009 · Cited by 461
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Experimental anti-tumor therapy in 3-D: Spheroids – old hat or new challenge?
Friedrich, J., Ebner, R., & Kunz-Schughart, L. A. (2007) · International Journal of Radiation Biology · doi:10.1080/09553000701727531 · Cited by 446
Three‑dimensional cell culture: A powerful tool in tumor research and drug discovery (Review)
Lv, D., Hu, Z., Lu, L., Lu, H., & Xu, X. (2017) · Oncology Letters · doi:10.3892/ol.2017.7134 · Cited by 337
Towards artificial tissue models: past, present, and future of 3D bioprinting
Arslan-Yildiz, A., Assal, R. E., Chen, P., Guven, S., Inci, F., & Demirci, U. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014103 · Cited by 301
The multicellular tumor spheroid model for high-throughput cancer drug discovery
LaBarbera, D. V., Reid, B. G., & Yoo, B. H. (2012) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2012.708334 · Cited by 255
Design of spherically structured 3D in vitro tumor models -Advances and prospects
Ferreira, L. P., Gaspar, V. M., & Mano, J. F. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.05.034 · Cited by 249
A reliable tool to determine cell viability in complex 3-d culture: the acid phosphatase assay
Friedrich, J., Eder, W., Castaneda, J., Doss, M., Huber, E., Ebner, R., & Kunz-Schughart, L. A. (2007) · SLAS DISCOVERY · doi:10.1177/1087057107306839 · Cited by 227
Patra, B., Peng, C.-C., Liao, W.-H., Lee, C.-H., & Tung, Y.-C. (2016) · Scientific Reports · doi:10.1038/srep21061 · Cited by 215
Sabhachandani, P., Motwani, V., Cohen, N., Sarkar, S., Torchilin, V., & Konry, T. (2016) · Lab on a Chip · doi:10.1039/c5lc01139f · Cited by 193
Wu, M.-H., Chang, Y.-H., Liu, Y.-T., Chen, Y.-M., Wang, S.-S., Wang, H.-Y., Lai, C.-S., & Pan, T.-M. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.11.027 · Cited by 42
Metadata
- Authors
- Zhang, X., Wang, W., Yu, W., Xie, Y., Zhang, X., Zhang, Y., & Ma, X.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2008-09-05
- Volume
- 21
- Issue
- 4
- Pages
- 1289-1296
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2095104577
- Cited by
- 162
- References
- 0
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.