The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Evolution of Group 14 Rhodamines as Platforms for Near-Infrared Fluorescence Probes Utilizing Photoinduced Electron Transfer
Abstract
The absorption and emission wavelengths of group 14 pyronines and rhodamines, which contain silicon, germanium, or tin at the 10 position of the xanthene chromophore, showed large bathochromic shifts compared to the original rhodamines, owing to stabilization of the LUMO energy levels by σ*-π* conjugation between group 14 atom-C (methyl) σ* orbitals and a π* orbital of the fluorophore. These group 14 pyronines and rhodamines retain the advantages of the original rhodamines, including high quantum efficiency in aqueous media (Φ(fl) = 0.3-0.45), tolerance to photobleaching, and high water solubility. Group 14 rhodamines have higher values of reduction potential than other NIR light-emitting original rhodamines, and therefore, we speculated their NIR fluorescence could be controlled through the photoinduced electron transfer (PeT) mechanism. Indeed, we found that the fluorescence quantum yield (Φ(fl)) of Si-rhodamine (SiR) and Ge-rhodamine (GeR) could be made nearly equal to zero, and the threshold level for fluorescence on/off switching lies at around 1.3-1.5 V for the SiRs. This is about 0.1 V lower than in the case of TokyoGreens, in which the fluorophore is well established to be effective for PeT-based probes. That is to say, the fluorescence of SiR and GeR can be drastically activated by more than 100-fold through a PeT strategy. To confirm the validity of this strategy for developing NIR fluorescence probes, we employed this approach to design two kinds of novel fluorescence probes emitting in the far-red to NIR region, i.e., a series of pH-sensors for use in acidic environments and a Zn(2+) sensor. We synthesized these probes and confirmed that they work well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry
Nolan, E. M., & Lippard, S. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar8001409 · Cited by 620
Cited by
A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins
Lukinavičius, G., Umezawa, K., Olivier, N., Honigmann, A., Yang, G., Plass, T., Mueller, V., Reymond, L., Corrêa Jr, I. R., Luo, Z.-G., et al. (2013) · Nature Chemistry · doi:10.1038/nchem.1546 · Cited by 893
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Ma, D., Bian, H., Gu, M., Wang, L., Chen, X., & Peng, X. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.215677 · Cited by 124
A general approach to the design of high-performance near-infrared (NIR) D-π-A type fluorescent dyes
Luo, X., Li, J., Zhao, J., Gu, L., Qian, X., & Yang, Y. (2019) · Chinese Chemical Letters · doi:10.1016/j.cclet.2019.03.012 · Cited by 119
Metadata
- Authors
- Koide, Y., Urano, Y., Hanaoka, K., Terai, T., & Nagano, T.
- Venue
- ACS Chemical Biology
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-03-17
- Volume
- 6
- Issue
- 6
- Pages
- 600-608
- ISSN
- 1554-8929 (ISSN-L)
- 1554-8937
- OpenAlex
- W2315391878
- Cited by
- 395
- References
- 2
- FWCI
- 8.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.