The DOI matches its Crossref record.
Electrically Conductive, Tough Hydrogels with pH Sensitivity
Abstract
Electrically conductive, mechanically tough hydrogels based on a double network (DN) comprised of poly(ethylene glycol) methyl ether methacrylate (PPEGMA) and poly(acrylic acid) (PAA) were produced. Poly(3,4-ethylenedioxythiophene) (PEDOT) was chemically polymerized within the tough DN gel to provide electronic conductivity. The effects of pH on the tensile and compressive mechanical properties of the fully swollen hydrogels, along with their electrical conductivity and swelling ratio were determined. Compressive and tensile strengths as high as 11.6 and 0.6 MPa, respectively, were obtained for hydrogels containing PEDOT with a maximum conductivity of 4.3 S cm –1 . This conductivity is the highest yet reported for hydrogel materials of high swelling ratios. These hydrogels may be useful as soft strain sensors because their electrical resistance changed significantly when cyclically loaded in compression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Han, L., Liu, K., Wang, M., Wang, K., Fang, L., Chen, H., Zhou, J., & Lu, X. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201704195 · Cited by 1,160
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Han, L., Lu, X., Wang, M., Gan, D., Deng, W., Wang, K., Fang, L., Liu, K., Chan, C. W., Tang, Y., et al. (2017) · Small · doi:10.1002/smll.201601916 · Cited by 699
Jalili, R., Razal, J. M., & Wallace, G. G. (2013) · Scientific Reports · doi:10.1038/srep03438 · Cited by 612
Self-citationTailoring the Swelling‐Shrinkable Behavior of Hydrogels for Biomedical Applications
Feng, W., & Wang, Z. (2023) · Advanced Science · doi:10.1002/advs.202303326 · Cited by 548
A mini review on hydrogels classification and recent developments in miscellaneous applications
Varaprasad, K., Raghavendra, G. M., Jayaramudu, T., Yallapu, M. M., & Sadiku, R. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.05.096 · Cited by 534
Zhao, Z., Xia, K., Hou, Y., Zhang, Q., Ye, Z., & Lu, J. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00800e · Cited by 490
An Anti‐Swellable Hydrogel Strain Sensor for Underwater Motion Detection
Ren, J., Liu, Y., Wang, Z., Chen, S., Ma, Y., Wei, H., & Lü, S. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202107404 · Cited by 395
A Strain‐Insensitive Stretchable Electronic Conductor: PEDOT:PSS/Acrylamide Organogels
Lee, Y., Kang, H., Gwon, S. H., Choi, G. M., Lim, S., Sun, J., & Joo, Y. (2016) · Advanced Materials · doi:10.1002/adma.201504606 · Cited by 332
Gan, D., Han, L., Wang, M., Xing, W., Xu, T., Zhang, H., Wang, K., Fang, L., & Lu, X. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b10280 · Cited by 267
Metadata
- Authors
- Naficy, S., Razal, J. M., Spinks, G. M., Wallace, G. G., & Whitten, P. G.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-08-27
- Volume
- 24
- Issue
- 17
- Pages
- 3425-3433
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W2041373967
- Cited by
- 162
- References
- 0
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.