The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Surface-Ligand-Dependent Cellular Interaction, Subcellular Localization, and Cytotoxicity of Polymer-Coated Quantum Dots
Abstract
Nanoparticle- and quantum-dot (QD)-based bioprobes are emerging as alternatives to small-molecule probes for in vitro and in vivo applications. However, their cellular interaction and cell uptake mechanism are significantly different from those of small-molecule probes and are extremely sensitive to surface ligands. These present a barrier in the development of nanoparticles and QDs as cellular probes. This work focused on the synthesis of various functionalized QDs with tunable surface charge, hydrophobicity, and functionalization with poly(ethylene glycol) (PEGylation) and their cellular interaction. We found that the surface functional groups of nanometer-sized probes significantly dictated their cellular interaction, subcellular localization, and cytotoxicity. A dose-dependent interaction was observed for all types of QDs, but the cationic surface charge or hydrophobicity would increase the cellular interaction as compared to the anionic surface charge. Cationic QDs rapidly entered cells and induced cytotoxicity, but hydrophobic QDs were stuck to the cell membrane and did not enter the cells. PEGylation of cationic QDs reduced their nonspecific binding and cytotoxicity, and a higher concentration of QDs was required for cellular entry. On the basis of these results, we were able to design different functionalized QD nanoprobes with balanced hydrophobicity and surface charge for cell membrane labeling and subcellular targeting. Mechanistic studies indicated a clathrin-mediated interaction and uptake for all types of QDs. The cellular interaction and uptake of 20−50 nm particles were primarily determined by their surface charges and ability to penetrate the cellular membrane, and the final destinations of the nanoparticles in the cell could be controlled by the appropriate design of surface ligands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cited by
New Generation Cadmium-Free Quantum Dots for Biophotonics and Nanomedicine
Xu, G., Zeng, S., Zhang, B., Swihart, M. T., Yong, K.-T., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00290 · Cited by 587
Meta-analysis of cellular toxicity for cadmium-containing quantum dots
Oh, E., Liu, R., Nel, A., Gemill, K. B., Bilal, M., Cohen, Y., & Medintz, I. L. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.338 · Cited by 502
Susumu, K., Oh, E., Delehanty, J. B., Blanco-Canosa, J. B., Johnson, B. J., Jain, V., Hervey, W. J., Algar, W. R., Boeneman, K., Dawson, P. E., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja201919s · Cited by 293
Metadata
- Authors
- Tan, S. J., Jana, N. R., Gao, S., Patra, P. K., & Ying, J. Y.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-02-24
- Volume
- 22
- Issue
- 7
- Pages
- 2239-2247
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W2017861164
- Cited by
- 168
- References
- 1
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface-Ligand-Dependent Cellular Interaction, Subcellular Localization, and Cytotoxicity of Polymer-Coated Quantum Dots. https://app.cochat.ai/papers/10.1021/cm902989f
- The paper
- Tan, S. J., Jana, N. R., Gao, S., Patra, P. K., & Ying, J. Y. (2010). Surface-Ligand-Dependent Cellular Interaction, Subcellular Localization, and Cytotoxicity of Polymer-Coated Quantum Dots. Chemistry of Materials. https://doi.org/10.1021/cm902989f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.