Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A Reliable Synthesis of Cubic Mesoporous MCM-48 Molecular Sieve

Xu, Jie, Luan, Zhaohua, He, Heyong, Zhou, Wuzong, Kevan, Larry·1998·Chemistry of Materials

Abstract

Powder X-ray diffraction (XRD), 29 Si magic-angle-spinning (MAS) NMR spectroscopy, and transmission electron microscopy (TEM) as well as N 2 adsorption have been employed to study the formation of various mesophases that lead to the synthesis of cubic mesoporous MCM-48 molecular sieve. A typical synthesis is performed at 373 K, pH = 11.8 using tetraethyl orthosilicate as the silicon source and cetyltrimethylammonium bromide (CTAB) as the structure-directing agent with a molar gel composition of 1:0.23:0.55:112SiO 2 /Na 2 O/CTAB/H 2 O. XRD shows that a disordered tubular mesophase (H 1 ) rapidly forms and then transforms to a layered phase (L 1 ) upon heating at 373 K for 5−10 h. After the hydrothermal treatment continues for 72 h, the layered phase (L 1 ) gradually transforms to a cubic MCM-48 mesophase (V), which is accompanied by a slight pH increase of about 0.2 units. Prolonged hydrothermal treatment for over 120 h results in further structural transformation from the cubic mesophase V to a second layered phase (L 2 ). 29 Si MAS NMR reveals that the L 2 layered phase has a more regular atomic arrangement than the other three mesophases. However, the silica condensation increases monotonicly in the order H 1 → L 1 → V → L 2 with hydrothermal treatment time. The cubic MCM-48 mesophase is not completely stable under hydrothermal synthesis conditions since it converts to the L 2 phase. This may account for the poor repeatability of prior syntheses of MCM-48 material. We show that cubic MCM-48 can be stabilized either by addition of acetic acid to maintain a constant gel pH or by selection of the reaction time to prevent further mesophase transformation. TEM and N 2 adsorption data show well-defined three-dimensional channels for the cubic MCM-48.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/cm980440d

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Metadata

Authors
Xu, J., Luan, Z., He, H., Zhou, W., & Kevan, L.
Venue
Chemistry of Materials
Published
1998-10-29
Volume
10
Issue
11
Pages
3690-3698
ISSN
  • 0897-4756 (ISSN-L)
  • 1520-5002
OpenAlex
W2092844268
Cited by
238
References
2
FWCI
9.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.