The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTFluorogenic and Chromogenic Chemosensors and Reagents for AnionsRamón Martínez-Máñez and Félix SancenónView Author Information GDDS, Departamento de Química, Universidad Politécnica de Valencia, Camino de Vera s/n, 46071-Valencia, Spain Cite this: Chem. Rev. 2003, 103, 11, 4419–4476Publication Date (Web):October 28, 2003Publication History Received16 May 2003Published online28 October 2003Published inissue 1 November 2003https://pubs.acs.org/doi/10.1021/cr010421ehttps://doi.org/10.1021/cr010421eresearch-articleACS PublicationsCopyright © 2003 American Chemical SocietyRequest reuse permissionsArticle Views15917Altmetric-Citations2865LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose SUBJECTS:Anions,Color,Fluorescence,Quenching,Receptors Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Supramolecular Chemistry: Concepts and Perspectives
Lehn, J. (1995) · Wiley eBooks · doi:10.1002/3527607439 · Cited by 9,864
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Design principles of fluorescent molecular sensors for cation recognition
Valeur, B. (2000) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(00)00246-0 · Cited by 2,377
Handbook of Fluorescence Spectra of Aromatic Molecules
(1971) · Elsevier eBooks · doi:10.1016/b978-0-12-092656-5.x5001-1 · Cited by 2,335
Artificial Organic Host Molecules for Anions
Schmidtchen, F. P., & Berger, M. (1997) · Chemical Reviews · doi:10.1021/cr9603845 · Cited by 1,788
Supramolecular chemistry of anions
Bianchi, A., Bowman‐James, K., & García‐España, E. (1997) · Cited by 1,371
A Long-Wavelength Fluorescent Chemodosimeter Selective for Cu(II) Ion in Water
Dujols, V., Ford, F., & Czarnik, A. W. (1997) · Journal of the American Chemical Society · doi:10.1021/ja971221g · Cited by 987
Chemical Communication in Water Using Fluorescent Chemosensors
Czarnik, A. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00046a003 · Cited by 943
Luminescent lanthanide sensors for pH, pO2 and selected anions
Parker, D. (2000) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(00)00241-1 · Cited by 815
Teaching Old Indicators New Tricks
Wiskur, S. L., Ait-Haddou, H., Lavigne, J. J., & Anslyn, E. V. (2001) · Accounts of Chemical Research · doi:10.1021/ar9600796 · Cited by 763
Fluorescence ratio imaging of cyclic AMP in single cells
Adams, S. R., Harootunian, A. T., Buechler, Y. J., Taylor, S. S., & Tsien, R. Y. (1991) · Nature · doi:10.1038/349694a0 · Cited by 696
Calorimetric determinations of absolute fluorescence quantum yields
Olmsted, J. (1979) · The Journal of Physical Chemistry · doi:10.1021/j100483a006 · Cited by 649
Sapphyrins: Versatile Anion Binding Agents
Sessler, J. L., & Davis, J. M. (2001) · Accounts of Chemical Research · doi:10.1021/ar980117g · Cited by 578
Colorimetric Fluoride Ion Sensing by Boron-Containing π-Electron Systems
Yamaguchi, S., Akiyama, S., & Tamao, K. (2001) · Journal of the American Chemical Society · doi:10.1021/ja015957w · Cited by 571
Anion coordination and anion-directed assembly: highlights from 1997 and 1998
Gale, P. (2000) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(99)00149-6 · Cited by 490
Chemosensors of Ion and Molecule Recognition
(1997) · Springer eBooks · doi:10.1007/978-94-011-3973-1 · Cited by 488
Luminescence Lifetime-Based Sensor for Cyanide and Related Anions
Anzenbacher, Tyson, D. S., Jursíková, K., & Castellano, F. N. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0259180 · Cited by 460
Gale, P. A., Sessler, J. L., & Král, V. (1998) · Chemical Communications · doi:10.1039/a706280j · Cited by 392
Dipyrrolylquinoxalines: Efficient Sensors for Fluoride Anion in Organic Solution
Black, C. B., Andrioletti, B., Try, A. C., Ruiperez, C., & Sessler, J. L. (1999) · Journal of the American Chemical Society · doi:10.1021/ja992579a · Cited by 382
A Fluorescent Anion Sensor That Works in Neutral Aqueous Solution for Bioanalytical Application
Mizukami, S., Nagano, T., Urano, Y., Odani, A., & Kikuchi, K. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0175643 · Cited by 371
A New Chromo-chemodosimeter Selective for Sulfide Anion
Jiménez, D., Martínez-Máñez, R., Sancenón, F., Ros-Lis, J. V., Benito, A., & Soto, J. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0347336 · Cited by 355
Self-citationNishizawa, S., Kato, Y., & Teramae, N. (1999) · Journal of the American Chemical Society · doi:10.1021/ja991497j · Cited by 351
Neutral anion receptors: design and application
Antonisse, M. M. G., & Reinhoudt, D. N. (1998) · Chemical Communications · doi:10.1039/a707529d · Cited by 339
Mizuno, T., Wei, W.-H., Eller, L. R., & Sessler, J. L. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017298t · Cited by 335
Chae, M. Y., & Czarnik, A. W. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00050a085 · Cited by 327
Ho, H. A., & Leclerc, M. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028765p · Cited by 295
A Chemosensor for Citrate in Beverages
Metzger, A., & Anslyn, E. V. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<649::aid-anie649>3.0.co;2-h · Cited by 293
Anion recognition: synthetic receptors for anions and their application in sensors
Snowden, T. S., & Anslyn, E. V. (1999) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(99)00034-4 · Cited by 291
Sun, S.-S., & Lees, A. J. (2000) · Chemical Communications · doi:10.1039/b004541l · Cited by 230
Chemosensor Ensemble with Selectivity for Inositol-Trisphosphate
Niikura, K., Metzger, A., & Anslyn, E. V. (1998) · Journal of the American Chemical Society · doi:10.1021/ja980990c · Cited by 229
Strong hydrogen bond-mediated complexation of H2PO4− by neutral bis-thiourea hosts
Bühlmann, P., Nishizawa, S., Xiao, K. P., & Umezawa, Y. (1997) · Tetrahedron · doi:10.1016/s0040-4020(96)01094-0 · Cited by 229
Selective fluorescence detection of fluoride using boronic acids
Cooper, C. R. (1998) · Chemical Communications · doi:10.1039/a801693c · Cited by 224
A new fluorescent PET chemosensor for fluoride ionsDedicated to the memory of D. J. Cram.
Kim, S. K., & Yoon, J. (2002) · Chemical Communications · doi:10.1039/b110139k · Cited by 209
Camiolo, S., Gale, P. A., Hursthouse, M. B., & Light, M. E. (2003) · Organic & Biomolecular Chemistry · doi:10.1039/b210848h · Cited by 189
J., D. L. J., Martínez‐Máñez, R., Sancenón, F., & Soto, J. (2002) · Tetrahedron Letters · doi:10.1016/s0040-4039(02)00363-5 · Cited by 156
Self-citationAllosteric Fluoride Anion Recognition by a Doubly Strapped Porphyrin
Takeuchi, M., Shioya, T., & Swager, T. M. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010917)40:18<3372::aid-anie3372>3.0.co;2-1 · Cited by 140
Chow, C., Chiu, B. K.-W., Lam, M. H., & Wong, W. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034891x · Cited by 138
A selective colorimetric anion sensor based on an amide group containing macrocycle
Piątek, P., & Jurczak, J. (2002) · Chemical Communications · doi:10.1039/b207335h · Cited by 124
Fluoride-Selective Binding in a New Deep Cavity Calix[4]pyrrole: Experiment and Theory
Woods, C. J., Camiolo, S., Light, M. E., Coles, S. J., Hursthouse, M. B., King, M. A., Gale, P. A., & Essex, J. W. (2002) · Journal of the American Chemical Society · doi:10.1021/ja025572t · Cited by 117
Yamamoto, H., Ori, A., Ueda, K., Dusemund, C., & Shinkai, S. (1996) · Chemical Communications · doi:10.1039/cc9960000407 · Cited by 114
Novel highly selective anion chemosensors based on 2,5-bis(2-hydroxyphenyl)-1,3,4-oxadiazole
Tong, H., Zhou, G., Wang, L., Jing, X., Wang, F., & Zhang, J. (2003) · Tetrahedron Letters · doi:10.1016/s0040-4039(02)02504-2 · Cited by 106
Oxyindolophyrin: A Novel Fluoride Receptor Derived from N-Confused Corrole Isomer
Furuta, H., Maeda, H., & Osuka, A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja015892x · Cited by 94
Sun, S., Anspach, J. A., Lees, A. J., et al. (2002) · Organometallics · doi:10.1021/om0109096 · Cited by 86
Yamamoto, M., Takeuchi, M., & Shinkai, S. (1998) · Tetrahedron · doi:10.1016/s0040-4020(98)00057-x · Cited by 74
Corma, A., Galletero, M. S., García, H., Palomares, E. J., & Rey, F. (2002) · Chemical Communications · doi:10.1039/b201523b · Cited by 69
Wu, F., & Jiang, Y. (2002) · Chemical Physics Letters · doi:10.1016/s0009-2614(02)00274-9 · Cited by 68
Isothiouronium-derived simple fluorescent chemosensors of anions
Kubo, Y., Ishihara, S., Tsukahara, M., & Tokita, S. (2002) · Journal of the Chemical Society Perkin Transactions 2 · doi:10.1039/b202953g · Cited by 64
A New Fluorescent Biosensor for Inositol Trisphosphate
Morii, T., Sugimoto, K., Makino, K., Otsuka, M., Imoto, K., & Mori, Y. (2002) · Journal of the American Chemical Society · doi:10.1021/ja016824d · Cited by 49
Takahashi, Y., Tanaka, D. A. P., Matsunaga, H., & Suzuki, T. M. (2002) · Journal of the Chemical Society Perkin Transactions 2 · doi:10.1039/b111702e · Cited by 32
Sotiriou‐Leventis, C., Mao, Z. X., & Rawashdeh, A. M. (2000) · The Journal of Organic Chemistry · doi:10.1021/jo0004557 · Cited by 24
Zepik (2001) · doi:10.1002/1521-3773(20010105)40:1
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
New sensing mechanisms for design of fluorescent chemosensors emerging in recent years
Wu, J., Liu, W., Ge, J., Zhang, H., & Wang, P. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00224k · Cited by 1,858
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Metadata
- Authors
- Martínez-Máñez, R., & Sancenón, F.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-28
- Volume
- 103
- Issue
- 11
- Pages
- 4419-4476
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2000088683
- Cited by
- 3,076
- References
- 52
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.