Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 371

The DOI matches its Crossref record.

A Fluorescent Anion Sensor That Works in Neutral Aqueous Solution for Bioanalytical Application

Mizukami, Shin, Nagano, Tetsuo, Urano, Yasuteru, Odani, Akira, Kikuchi, Kazuya·2002·Journal of the American Chemical Society

Abstract

Anion recognition and anion sensing are of interest because anions play many important roles in living organisms. Most currently known anion sensors work only in organic solution, but sensors for biological applications are required to function in neutral aqueous solution. We have designed and synthesized a novel fluorescent sensor for anions. The sensor molecule 1-Cd(II) contains 7-amino-4-trifluoromethylcoumarin as a fluorescent reporter and Cd(II)-cyclen (1,4,7,10-tetraazacyclododecane) as an anion host. In neutral aqueous solution, Cd(II) of 1-Cd(II) is coordinated by the four nitrogen atoms of cyclen and the aromatic amino group of coumarin. When various anions are added to 100 mM HEPES buffer solution (pH 7.4) containing 1-Cd(II), the aromatic amino group of coumarin is displaced from Cd(II), causing a change of the excitation spectrum. While pyrophosphate and citrate were detected with high sensitivity, fluoride and perchlorate produced no response. Among organic anions, ATP and ADP gave strong signals, while cAMP showed little signal. By utilizing the different affinities of the sensor for AMP and cAMP, the activity of phosphodiesterase, which cleaves cyclic nucleotide, was monitored in real-time. The sensor should have many biochemical and analytical applications and the sensing principle should be widely applicable to the sensing of other molecules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja0175643

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 371

Metadata

Authors
Mizukami, S., Nagano, T., Urano, Y., Odani, A., & Kikuchi, K.
Venue
Journal of the American Chemical Society
Published
2002-03-21
Volume
124
Issue
15
Pages
3920-3925
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2058075394
Cited by
371
References
0
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Fluorescent Anion Sensor That Works in Neutral Aqueous Solution for Bioanalytical Application. https://app.cochat.ai/papers/10.1021/ja0175643
The paper
Mizukami, S., Nagano, T., Urano, Y., Odani, A., & Kikuchi, K. (2002). A Fluorescent Anion Sensor That Works in Neutral Aqueous Solution for Bioanalytical Application. Journal of the American Chemical Society. https://doi.org/10.1021/ja0175643

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.