The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
In Vivo Photoacoustic Tomography of Chemicals: High-Resolution Functional and Molecular Optical Imaging at New Depths
Open accessAbstract
High-resolution volumetric optical imaging modalities, \nsuch as confocal microscopy, two-photon microscopy, and \noptical coherence tomography, have become increasingly \nimportant in the biomedical imaging field. However, due to \nstrong light scattering, the penetration depths of these \nimaging modalities are limited to the optical transport mean \nfree path in biological tissues, for example, ∼1 mm in the \nskin. Photoacoustic tomography (PAT), an emerging hybrid \nimaging modality that can provide strong endogenous and \nexogenous optical absorption contrasts with high ultrasonic \nspatial resolution using the photoacoustic (PA) effect, has \novercome the fundamental depth limitation. The image \nresolution is scalable with the ultrasonic frequency. The \nimaging depth is limited to the reach of photons and up to \na few centimeters deep in biological tissues. This Review \nwill focus on the following aspects of PAT described in \nworks published from 2003 to 2009: (1) multiscale PAT \nsystems, (2) morphological and functional PAT using \nintrinsic contrasts (hemoglobin or melanin), and (3) functional \nand molecular PAT using exogenous contrast agents \n(organic dyes, nanoparticles, reporter genes, or fluorescence \nproteins).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumorigenesis and the angiogenic switch
Bergers, G., & Benjamin, L. E. (2003) · Nature reviews. Cancer · doi:10.1038/nrc1093 · Cited by 3,559
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Heesakkers, R. A., Hövels, A. M., Jager, G. J., van den Bosch, H. C., Witjes, J. A., Raat, H. P., Severens, J. L., Adang, E. M., van der Kaa, C. H., Fütterer, J. J., et al. (2008) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70203-1 · Cited by 307
Cited by
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Nanomaterials for Theranostics: Recent Advances and Future Challenges
Lim, E.-K., Kim, T., Paik, S., Haam, S., Huh, Y.-M., & Lee, K. (2015) · Chemical Reviews · doi:10.1021/cr300213b · Cited by 1,233
Polymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
Compound Copper Chalcogenide Nanocrystals
Coughlan, C., Ibáñez, M., Dobrozhan, O., Singh, A., Cabot, A., & Ryan, K. M. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00376 · Cited by 930
Red‐Emissive Carbon Dots for Fluorescent, Photoacoustic, and Thermal Theranostics in Living Mice
Ge, J., Jia, Q., Liu, W., Guo, L., Liu, Q., Lan, M., Zhang, H., Meng, X., & Wang, P. (2015) · Advanced Materials · doi:10.1002/adma.201500323 · Cited by 885
Metadata
- Authors
- Kim, C., Favazza, C., & Wang, L. V.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-08
- Volume
- 110
- Issue
- 5
- Pages
- 2756-2782
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2096097264
- Cited by
- 807
- References
- 3
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.