Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Increased Thermal Conductivity of Eicosane-Based Composite Phase Change Materials in the Presence of Graphene Nanoplatelets

Fang, Xin, Fan, Li-Wu, Ding, Qing, Wang, Xiao, Yao, Xiao-Li, Hou, Jian-Feng, Yu, Zi-Tao, Cheng, Guan-Hua, Hu, Ya-Cai, Cen, Ke-Fa·2013·Energy & Fuels

Abstract

Alkanes and their mixtures (paraffins) have widely been used as phase change materials (PCMs) for low-to-medium temperature thermal energy storage. Among the various alkanes, eicosane, with a nominal melting temperature of 37 °C, has emerged in energy-storage-based passive thermal management technologies, for electronics for example. In an effort to increase the thermal conductivity of eicosane, the effect of adding graphene nanoplatelets (GNPs) as thermally conductive nanofillers was investigated experimentally. The composite PCM samples were prepared by dispersing GNPs in liquid eicosane at various loadings (0, 1, 2, 5, and 10 wt.%) without any surfactants. Thermal conductivity of the composite PCM samples in their solid phase was then measured by means of the transient plane source technique at elevated temperatures from 10 to 35 °C. Latent heat of fusion and melting point of the samples were also characterized using a differential scanning calorimeter. It was shown that for the highest loading examined (10 wt.%), the relative thermal conductivity enhancement is above 400% at 10 °C, indicating that the emerging GNPs have much better performance than the conventional nanofillers attempted in the available literature, such as metal/oxide nanoparticles and carbon nanotubes. Reduced thermal interface resistance, related to the unique two-dimensional planar morphology of GNPs, was interpreted to be responsible for their superior performance. The matrix/filler thermal interface resistance was estimated to range from 6 × 10 –9 to 9 × 10 –9 m 2 K/W. In contrast to the markedly increased thermal conductivity, however, the penalty of decrease in the energy storage capacity, caused by the presence of GNPs, was shown to be less significant.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ef400702a

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 261

Metadata

Authors
Fang, X., Fan, L.-W., Ding, Q., Wang, X., Yao, X.-L., Hou, J.-F., Yu, Z.-T., Cheng, G.-H., Hu, Y.-C., & Cen, K.-F.
Venue
Energy & Fuels
Published
2013-06-13
Volume
27
Issue
7
Pages
4041-4047
ISSN
  • 0887-0624 (ISSN-L)
  • 1520-5029
OpenAlex
W2322414444
Cited by
261
References
31
FWCI
22.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.