Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 171

The DOI matches its Crossref record.

Gas/Solid Partitioning of Semivolatile Organic Compounds (SOCs) to Air Filters. 3. An Analysis of Gas Adsorption Artifacts in Measurements of Atmospheric SOCs and Organic Carbon (OC) When Using Teflon Membrane Filters and Quartz Fiber Filters

Mader, Brian T., Pankow, James F. · 2001 · Environmental Science & Technology

Abstract

Adsorption of gaseous semivolatile organic compounds (SOCs) onto the filter(s) of a filter/sorbent sampler is a potential source of measurement error when determining specific SOCs as well as organic carbon (OC) levels in the atmosphere. This work examines partitioning to both Teflon membrane filters (TMFs) and quartz fiber filters (QFFs) for purposes of predicting the magnitude of the compound-dependent gas adsorption artifact as a function of various sampling parameters. The examination is based on values of Kp,face (m3 cm(-2)), the gas/filter partition coefficient expressed as [ng sorbed per cm2 of filter face]/[ng per m3 in the gas phase]. Values of Kp,face were calculated based on literature values of the gas/solid partition coefficient Kp,s [ng sorbed per m2 of filter]/[ng per m3 in gas phase] for the adsorption of various polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzodioxins (PCDDs), and polychlorinated dibenzofurans (PCDFs) to TMFs, and for the adsorption of PAHs to QFFs. At relative humidity (RH) values below approximately 50%, the Kp,face values for PAHs are lower on TMFs than on ambient-backup QFFs. The gas adsorption artifact will therefore be lower for PAHs with TMFs than with QFFs under these conditions. In the past, corrections for the gas/filter adsorption artifact have been made by using a backup filter, and subtracting the mass amount of each compound found on the backup filter from the total (particle phase + sorbed on filter) amount found on the front filter. This procedure assumes that the ng cm(-2) amounts of each SOC sorbed on the front and backup filters are equal. That assumption will only be valid after both filters have reached equilibrium with each of the gaseous SOCs in the incoming sample air. The front filter will reach equilibrium first. The minimum air sample volume Vmin,f+b required to reach gas/filter sorption equilibrium with a pair of filters is 2Kp,face Afilter where Afilter (cm2) is the per-filter face area. Kp,face values, and therefore Vmin,f+b values, depend on the compound, relative humidity (RH), temperature, and filter type. Compound-dependent Vmin,f+b values are presented for PAHs and PCDD/Fs on both TMFs and QFFs. Compound-dependent equations which give the magnitude of the filter adsorption artifact are presented for a range of different sampling arrangements and circumstances. The equations are not intended for use in actually correcting field data because of uncertainties in actual field values of relevant parameters such as the compound-dependent Kp,face and gas/particle Kp values, and because of the fact that the equations assume ideal step-function chromatographic movement of gas-phase compounds through the adsorbing filter. Rather, the main utility of the equations is as guidance tools in designing field sampling efforts that utilize filter/sorbent samplers and in evaluating prior work. The results indicate that some backup-filter-based corrections described in the literature were carried out using sample volumes that were too small to allow proper correction for the gas adsorption artifactfor some specific SOCs of interest. Similar conclusions are reached regarding artifacts associated with the measurement of gaseous and particulate OC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es0015951

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Mader, B. T., & Pankow, J. F.
Venue
Environmental Science & Technology
Published
2001-08-08
Volume
35
Issue
17
Pages
3422-3432
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2012405438
Cited by
171
References
0
FWCI
10.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.