Use of Time- and Chemically Resolved Particulate Data To Characterize the Infiltration of Outdoor PM2.5 into a Residence in the San Joaquin Valley
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Recent studies associate particulate air pollution with adverse health effects. The indoor exposure to particles of outdoor origin is not well-characterized, particularly for individual chemical species. In response to this, a field study in an unoccupied, single-story residence in Clovis, CA, was conducted. Real-time particle monitors were used both outdoors and indoors to quantity PM2.5 nitrate, sulfate, and carbon. The aggregate of the highly time-resolved sulfate data, as well as averages of these data, was fit using a time-averaged form of the infiltration equation, resulting in reasonable values for the penetration coefficient and deposition loss rate. In contrast, individual values of the indoor/outdoor ratio can vary significantly from that predicted by the model for time scales ranging from a few minutes to several hours. Measured indoor ammonium nitrate levels were typically significantly lower than expected solely on the basis of penetration and deposition losses. The additional reduction is due to the transformation of ammonium nitrate into ammonia and nitric acid gases indoors, which are subsequently lost by deposition and sorption to indoor surfaces. This result illustrates that exposure assessments based on total outdoor particle mass can obscure the actual causal relationships for indoor exposures to particles of outdoor origin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Effects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416
Self-citationRelative contribution of outdoor and indoor particle sources to indoor concentrations
Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P. (2000) · Environmental Science & Technology · doi:10.1021/es990348y · Cited by 411
Indoor–outdoor relationships of respirable sulfates and particles
Dockery, D. W., & Spengler, J. D. (1981) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(81)90036-6 · Cited by 273
Cited by
Fromme, H., Diemer, J., Dietrich, S., Cyrys, J., Heinrich, J., Lang, W., Kiranoglu, M., & Twardella, D. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.04.047 · Cited by 227
The transformation of outdoor ammonium nitrate aerosols in the indoor environment
Lunden, M. M., Revzan, K. L., Fischer, M. L., Thatcher, T. L., Littlejohn, D., Hering, S. V., & Brown, N. J. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.035 · Cited by 152
“tively.The latter value of 1 is justified because high ventilation rates were obtained using a fan mounted in the master bedroom window ( Lunden et al., 2003 ).”
BackgroundSelf-citationFazli, T., & Stephens, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.047 · Cited by 35
Metadata
- Authors
- Lunden, M. M., Thatcher, T. L., Hering, S. V., & Brown, N. J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-19
- Volume
- 37
- Issue
- 20
- Pages
- 4724-4732
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2052384334
- Cited by
- 48
- References
- 4
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Time- and Chemically Resolved Particulate Data To Characterize the Infiltration of Outdoor PM2.5 into a Residence in the San Joaquin Valley. https://app.cochat.ai/papers/10.1021/es026387i
- The paper
- Lunden, M. M., Thatcher, T. L., Hering, S. V., & Brown, N. J. (2003). Use of Time- and Chemically Resolved Particulate Data To Characterize the Infiltration of Outdoor PM2.5 into a Residence in the San Joaquin Valley. Environmental Science & Technology. https://doi.org/10.1021/es026387i
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.