Measured Concentrations of VOCs in Several Non-Residential Microenvironments in the United States
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Individuals spend about 25% of their time in non-residential indoor microenvironments. For some of these microenvironments, particularly stores and restaurants, exposures to volatile organic compounds (VOCs), have not been well characterized. In the Boston Exposure Assessment in Microenvironments (BEAM) study, sampling using scripted activities was conducted in stores, restaurants, and transportation in the summer of 2003 and winters of 2004 and 2005. A suite of VOCs including hydrocarbons, several chlorinated compounds, and aldehydes was analyzed. Nine store types were sampled using a composite design to enable a greater number of stores to be visited. Stores had higher concentrations of formaldehyde, toluene, ethylbenzene, xylenes, and styrene than other microenvironments, particularly in certain store types. Geometric mean formaldehyde levels were highest in the housewares stores, at 53 microg/m3 (95% CI = 43, 66). Geometric mean toluene levels were highest in multipurpose stores, at 76 microg/m3 (95% CI = 50, 118). The levels observed in stores were several times higherthan levels found in transportation microenvironments, and indicate strong indoor sources. In contrast, benzene did not have significantly higher levels in stores than typically found outdoors. Concentrations of formaldehyde and benzene, ethylbenzene, xylenes, and styrene were strongly influenced by the presence of smoking in the dining microenvironment. Chloroform levels were higher in restaurants than in other microenvironments, with a geometric mean of 1.1 microg/m3 (95% CI = 0.7, 1.8). The VOC concentrations found in stores and restaurants in this study are a potentially important source of exposure for sensitive individuals or people who work in these microenvironments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Restaurants had higher levels of BTEX and sometimes chloroform, especially near cooking stoves in dining areas, for example, at Korean barbeque restaurants [54, 55].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [55]
Citations
Cites
Markov Chain Monte Carlo in Practice
Gasparini, M. (1997) · Technometrics · doi:10.1080/00401706.1997.10485132 · Cited by 1,879
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Potential reactions among indoor pollutants
Weschler, C. J., & Shields, H. C. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(97)00219-7 · Cited by 257
Indoor chemistry: ozone, volatile organic compounds, and carpets
Weschler, C. J., Hodgson, A. T., & Wooley, J. D. (1992) · Environmental Science & Technology · doi:10.1021/es00036a006 · Cited by 233
Emissions of volatile organic compounds from building materials and consumer products
Wallace, L. A., Pellizzari, E., Leaderer, B., Zelon, H., & Sheldon, L. (1987) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(87)90017-5 · Cited by 211
Wallace, L. A., Pellizzari, E. D., Hartwell, T. D., Sparacino, C., Whitmore, R., Sheldon, L., Zelon, H., & Perritt, R. (1987) · Environmental Research · doi:10.1016/s0013-9351(87)80030-0 · Cited by 204
Emission Rates of Formaldehyde from Materials and Consumer Products Found in California Homes
Kelly, T. J., Smith, D. L., & Satola, J. (1999) · Environmental Science & Technology · doi:10.1021/es980592+ · Cited by 201
Exposures to Benzene and Other Volatile Compounds from Active and Passive Smoking
Wallace, L., Pellizzari, E., Hartwell, T. D., Perritt, R., & Ziegenfus, R. (1987) · Archives of Environmental Health: An International Journal · doi:10.1080/00039896.1987.9935820 · Cited by 195
The influence of personal activities on exposure to volatile organic compounds
Wallace, L. A., Pellizzari, E. D., Hartwell, T. D., Davis, V., Michael, L. C., & Whitmore, R. W. (1989) · Environmental Research · doi:10.1016/s0013-9351(89)80047-7 · Cited by 162
Daisey, J. M., Hodgson, A. T., Fisk, W. J., Mendell, M. J., & Brinke, J. T. (1994) · Atmospheric Environment · doi:10.1016/1352-2310(94)00200-5 · Cited by 153
Research works printed but not linked: 31
- Payne-Sturges D. C., 2004, Environ. Health Perspect., 112, 598
- Clayton C. A., 1999, J. Exposure Anal. Environ. Epidemiol., 9, 392
- Gordon S., 1999, J. Exposure Anal. Environ. Epidemiol., 9, 470
- Edwards R. D., 2001, Atmos. Environ., 35, 4543
- Edwards R. D., 2001, Atmos. Environ., 35, 4841
- Ozkaynak H., 1987, Indoor Air '87: Proceedings of the 4th International Conference on Indoor Air Quality and Climate, Institute for Water, Soil, and Air Hygiene, Berlin (West)
- Anderson M. J., 2001, J. Exposure Anal. Environ. Epidemiol., 11, 307
- Etkin D. S., 1996, Cutter Information Corp: Arlington
- Sack T. M., 1992, Atmos. Environ., 26, 1070
- Tichenor B. A., 1988, J. Air Pollution Control Assoc., 38, 268
- Kleipeis N. E., 2001, J. Exposure Anal. Environ. Epidemiol., 11, 252
- Chan C. C., 1991, Environ. Sci. Technol., 25, 972
- Chan C. C., 1991, J. Air Waste Manage. Assoc., 41, 1600
- Lawryk N. J., 1995, J. Exposure Anal. Environ. Epidemiol., 5, 531
- Rodes C., 1998, South Coast Air Quality Management District
- Weisel C. P., 1992, J. Exposure Anal. Environ. Epidemiol., 2, 96
- Jo W., 1996, J. Air Waste Manage. Assoc., 46, 754
- Lau W., 2003, Sci. Total Environ., 308, 155
- Lioy P. J., 1994, J. Exposure Anal. Environ. Epidemiol., 4, 441
- Sheldon L. S., 1988, Vol I
- Sheldon L. S., 1988, Vol II
- Lee S.-C., 2002, Atmos. Environ., 36, 1940
- Guo H., 2004, Environ. Res., 94, 66
- Kim Y. M., 2001, Environ. Sci. Technol., 35, 1004
- Gilks W. R., 1994, Statistician, 43, 177
- Spiegelhalter D. J., Winbugs version 1.4 User Manual. MRC Biostatistics Unit
- Fitzmaurice, G. M.; Laird, N. M.; Ware, J. H. InApplied Longitudinal Analysis; Wiley Series in Probability and Statistics: Hoboken, NJ, 2004; pp 76−78.
- Brown S. K, 1999, Indoor Air, 9, 215
- Morrison G. C., 2002, Environ. Sci. Technol., 34, 4968
- Destaillats H., 2006, Environ. Sci. Technol., 40, 4428
- National Toxicology Program., 2005, Report on Carcinogens
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Environmental and human health impacts of volatile organic compounds: A perspective review
Zhou, X., Zhou, X., Wang, C., & Zhou, H. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2022.137489 · Cited by 480
Benzene exposure: An overview of monitoring methods and their findings
Weisel, C. P. (2010) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2009.12.030 · Cited by 230
Barro, R., Regueiro, J., Llompart, M., & Garcia-Jares, C. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.10.117 · Cited by 198
Ranking Cancer Risks of Organic Hazardous Air Pollutants in the United States
Loh, M. M., Levy, J. I., Spengler, J. D., Houseman, E. A., & Bennett, D. H. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.9884 · Cited by 178
Self-citationOhura, T., Amagai, T., Shen, X., Li, S., Zhang, P., & Zhu, L. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.09.022 · Cited by 162
Xie, R., Ji, J., Guo, K., Lei, D., Fan, Q., Leung, D. Y. C., & Huang, H. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.09.025 · Cited by 108
Indoor acrolein emission and decay rates resulting from domestic cooking events
Seaman, V. Y., Bennett, D. H., & Cahill, T. M. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.08.043 · Cited by 100
Self-citationVolatile Organic Compounds in Small- and Medium-Sized Commercial Buildings in California
Wu, X. (., Apte, M. G., Maddalena, R., & Bennett, D. H. (2011) · Environmental Science & Technology · doi:10.1021/es202132u · Cited by 97
Self-citationSheu, R., Stönner, C., Ditto, J. C., Klüpfel, T., Williams, J., & Gentner, D. R. (2020) · Science Advances · doi:10.1126/sciadv.aay4109 · Cited by 98
Measured and Modeled Personal Exposures to and Risks from Volatile Organic Compounds
Dodson, R. E., Houseman, E. A., Levy, J. I., Spengler, J. D., Shine, J. P., & Bennett, D. H. (2007) · Environmental Science & Technology · doi:10.1021/es071127s · Cited by 71
Self-citationHuang, X., Han, D., Cheng, J., Chen, X., Zhou, Y. S., Liao, H., Dong, W. G., & Yuan, C. (2019) · Environmental Science and Pollution Research · doi:10.1007/s11356-019-06881-6 · Cited by 67
Huang, L., Qian, H., Deng, S., Guo, J., Li, Y., Zhao, W., & Yang, Y. (2018) · Atmospheric Environment · doi:10.1016/j.atmosenv.2018.06.009 · Cited by 67
Kumar, A., Singh, B. P., Punia, M., Singh, D., Kumar, K., & Jain, V. K. (2014) · Indoor Air · doi:10.1111/ina.12096 · Cited by 61
Budgets of Organic Carbon Composition and Oxidation in Indoor Air
Price, D. J., Day, D. A., Pagonis, D., Stark, H. J., Algrim, L. B., Handschy, A. V., Liu, S., Krechmer, J., Miller, S. L., Hunter, J. F., et al. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b04689 · Cited by 61
Lin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
“Restaurants had higher levels of BTEX and sometimes chloroform, especially near cooking stoves in dining areas, for example, at Korean barbeque restaurants [54, 55].”
Wang, S., Liu, S., Chen, X., Guo, Y., Xu, X., Yang, L., Zhao, Y., Chen, C., Liang, H., & Hao, R. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.139901 · Cited by 59
Milner, J., Vardoulakis, S., Chalabi, Z., & Wilkinson, P. (2010) · Environment International · doi:10.1016/j.envint.2010.08.015 · Cited by 56
Gokhale, S. B., Kohajda, T., & Schlink, U. (2008) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2008.08.025 · Cited by 58
Indoor air quality in a metropolitan area metro using fuzzy logic assessment system
Assimakopoulos, M.-N., Dounis, A. I., Spanou, A., & Santamouris, M. (2013) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2012.12.043 · Cited by 52
Emissions of two phthalate esters and BDE 209 to indoor air and their impact on urban air quality
Cousins, A. P., Holmgren, T., & Remberger, M. (2013) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2013.10.023 · Cited by 51
Constituents of volatile organic compounds of evaporating essential oil
Chiu, H., Chiang, H., Lo, C.-C., Chen, C.-Y., & Chiang, H. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.08.002 · Cited by 51
Horemans, B., & Grieken, R. V. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.01.010 · Cited by 53
Variability of Total Volatile Organic Compounds (TVOC) in the Indoor Air of Retail Stores
Jia, C., Cao, K., Valaulikar, R., Fu, X., & Sorin, A. B. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16234622 · Cited by 47
Pérez, R. L., Ayala, C. E., Park, J.-Y., Choi, J., & Warner, I. M. (2021) · Chemosensors · doi:10.3390/chemosensors9070153 · Cited by 44
Sources and migration of volatile organic compounds in mixed-use buildings
Jia, C., Batterman, S., Godwin, C., Charles, S. M., & Chin, J.-Y. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00643.x · Cited by 40
Amodio, M., Dambruoso, P. R., de Gennaro, G., de Gennaro, L., Loiotile, A. D., Marzocca, A., Stasi, F., de Trizio, L., & Tutino, M. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2544-1 · Cited by 40
Model Development and Validation of Personal Exposure to Volatile Organic Compound Concentrations
Delgado-Saborit, J. M., Aquilina, N. J., Meddings, C., Baker, S. G., & Harrison, R. M. (2009) · Environmental Health Perspectives · doi:10.1289/ehp.0900561 · Cited by 36
Spatial and temporal variability in VOC levels within a commercial retail building
Eklund, B. M., Burkes, S., Morris, P., & Mosconi, L. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00537.x · Cited by 35
Cometto‐Muñiz, J. E., & Abraham, M. H. (2015) · Chemosphere · doi:10.1016/j.chemosphere.2014.12.089 · Cited by 35
Ventilation and indoor air quality in retail stores: A critical review (RP-1596)
Zaatari, M., Nirlo, É. L., Jareemit, D., Crain, N., Srebric, J., & Siegel, J. A. (2013) · Science and Technology for the Built Environment · doi:10.1080/10789669.2013.869126 · Cited by 37
Volatile organic compounds in fourteen U.S. retail stores
Nirlo, E. L., Crain, N., Corsi, R. L., & Siegel, J. A. (2014) · Indoor Air · doi:10.1111/ina.12101 · Cited by 30
Impact of regulation on indoor volatile organic compounds in new unoccupied apartment in Korea
Lim, S., Lee, K., Seo, S., & Jang, S.-K. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.01.020 · Cited by 32
Jin, S., Zhong, L., Zhang, X., Li, X., Li, B., & Fang, X. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20105829 · Cited by 30
Rush-hour aromatic and chlorinated hydrocarbons in selected subway stations of Shanghai, China
Zhang, Y. L., Li, C., Wang, X., Guo, H. F., Feng, Y., & Chen, J. (2012) · Journal of Environmental Sciences · doi:10.1016/s1001-0742(11)60736-5 · Cited by 26
Contaminant levels, source strengths, and ventilation rates in California retail stores
Chan, W. R., Cohn, S., Sidheswaran, M., Sullivan, D. P., & Fisk, W. J. (2014) · Indoor Air · doi:10.1111/ina.12152 · Cited by 26
Asif, Z., Chen, Z., Haghighat, F., Nasiri, F., & Dong, J. (2022) · Environmental Management · doi:10.1007/s00267-022-01732-6 · Cited by 29
Phthalates and polybrominated diphenyl ethers in retail stores
Xu, Y., Liang, Y., Urquidi, J. R., & Siegel, J. A. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.01.019 · Cited by 30
Abraham, M. H., Gola, J. M. R., & Cometto‐Muñiz, J. E. (2015) · Environment International · doi:10.1016/j.envint.2015.07.012 · Cited by 25
Huy, L. N., Lee, S. C., & Zhang, Z. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.10.152 · Cited by 24
Indoor air quality in shopping and storage areas
Robert, L., Guichard, R., Klingler, J., Cochet, V., & Mandin, C. (2020) · Indoor Air · doi:10.1111/ina.12783 · Cited by 21
Chiappini, L., Dagnelie, R., Sassine, M., Fuvel, F., Fable, S., Tran-Thi, T.-H., & George, C. (2010) · Air Quality Atmosphere & Health · doi:10.1007/s11869-010-0102-7 · Cited by 15
Comparative Modeling Approaches for Personal Exposure to Particle-Associated PAH
Aquilina, N. J., Delgado-Saborit, J. M., Gauci, A., Baker, S. G., Meddings, C., & Harrison, R. M. (2010) · Environmental Science & Technology · doi:10.1021/es102529k · Cited by 15
Ochs, S. D. M., Furtado, L. D. A., & Netto, A. D. P. (2015) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-4021-2 · Cited by 12
A new device for formaldehyde and total aldehydes real-time monitoring
Sassine, M., Picquet‐Varrault, B., Perraudin, É., Chiappini, L., Doussin, J., & George, C. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-2010-5 · Cited by 13
Work Exposure to VOC in Storage Areas of Retail Stores
Robert, L., Guichard, R., & Klingler, J. (2020) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaa103 · Cited by 8
Geiss, O., Barrero-Moreno, J., & Kotzias, D. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00681.x · Cited by 7
Hallberg, K. E., Levy, L. C., Gonzalez-Abraham, R., Lutes, C. C., Lund, L. G., & Caldwell, D. (2021) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2021.1930286 · Cited by 7
Maripuu, M.-L. (2009) · Chalmers Publication Library (Chalmers University of Technology) · Cited by 7
Contaminant levels and source strengths in U.S. retail stores A pilot study
Chan, W. R. (2012) · eScholarship (California Digital Library) · Cited by 6
Castellani, F., Antonucci, A., Pindinello, I., Protano, C., & Vitali, M. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191912052 · Cited by 8
Loh, M. M., Houseman, E. A., Levy, J. I., Spengler, J. D., & Bennett, D. H. (2008) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2008.62 · Cited by 6
Self-citationSampaio, E. F. S., Guimarães, V., Soares, O. S. G. P., Pereira, M. F. R., Rodrigues, C. S. D., & Madeira, L. M. (2022) · Nanomaterials · doi:10.3390/nano12193274 · Cited by 6
Draft toxicological profile for trichloroethylene
Todd, G., Ruíz, P., Mumtaz, M. M., Taylor, J., Wohlers, D., Diamond, G., Coley, C., & Citra, M. J. (2014) · Cited by 5
Geraldino, B. R., Nunes, R. F. N., Gomes, J. B., da Poça, K. S., Toledo, T., Otero, U. B., & Sarpa, M. (2021) · Revista Brasileira de Medicina do Trabalho · doi:10.47626/1679-4435-2020-590 · Cited by 39
Breen, M. S., Isakov, V., Prince, S. E., McGuinness, K. L., Egeghy, P. P., Stephens, B., Arunachalam, S., Stout, D., Walker, R., Alston, L., et al. (2021) · Sensors · doi:10.3390/s21165659 · Cited by 4
Characterization of Volatile Organic Compounds in New Residential Buildings Before Moving-in
Shin, S.-H., & Jo, W. (2012) · Journal of Environmental Science International · doi:10.5322/jes.2012.21.1.11 · Cited by 4
Lawrence Berkeley National Lab. (LBNL), B., Chan, W., USDOE Office of Science (SC), Sidheswaran, M., Sullivan, D., Cohn, S., & Fisk, W. J. (2012) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1172719 · Cited by 4
Ichihara, M., Yamamoto, A., Kakutani, N., Sudo, M., & Takakura, K. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-016-7990-5 · Cited by 3
Wei, Y., Wang, X., Ji, M., Deng, S., Zhou, M., & Huang, L. (2025) · Air Quality Atmosphere & Health · doi:10.1007/s11869-025-01695-7 · Cited by 3
Halios, C. H., Assimakopoulos, M.-N., Chrisafis, D. S. S., & Santamouris, M. (2010) · International Journal of Ventilation · doi:10.1080/14733315.2010.11683859 · Cited by 3
Ventilation Relevant Contaminants of Concern in Commercial Buildings Screening Process and Results
Parthasarathy, S., USDOE Office of Science (SC), McKone, T. E., & Apte, M. G. (2011) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1172122 · Cited by 3
Exposure to Environmental Hazards and Effects on Chronic Disease
Loh, M. M. (2016) · Molecular and integrative toxicology · doi:10.1007/978-3-319-43142-0_2 · Cited by 2
Self-citationMethod of Lacquer Products on Emissions of Volatile Organic Compounds
Stachowiak–Wencek, A., & Pradzynski, W. (2015) · Drvna industrija · doi:10.5552/drind.2015.1358 · Cited by 1
Exposure to some carcinogenic compounds in air, with special reference to wood smoke
Gustafson, P. (2009) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 1
Multi-tool formaldehyde measurements in simulated and real atmosphere for indoor air monitoring
Chiappini, L., Dagnelie, R., Sassine, M., Fuvel, F., Fable, S., Tran-Thi, T.-H., & George, C. (2009) · HAL · Cited by 1
Stachowiak–Wencek, A., & Pradzynski, W. (2013) · Drewno Prace Naukowe Doniesienia Komunikaty = Wood Research Papers Reports Announcements · doi:10.12841/wood.1644-3985.043.03
Report: 20 Suspected Carcinogens Need More Research to Fill Knowledge Gaps
Eastman, P. (2010) · Oncology Times · doi:10.1097/01.cot.0000392892.75088.28
Towards a new index to qualify indoor air quality and thermal comfort in storage areas
Guichard, R., Robert, L., & Klingler, J. (2025) · E3S Web of Conferences · doi:10.1051/e3sconf/202567201042
Caron, A. (2016) · theses.fr (ABES) · doi:10.70675/5996948dz4f59z4106zbefbzc7bdd8d1f977 · Cited by 2
Robert, L., Guichard, R., & Klingler, J. (2026) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxag035
Metadata
- Authors
- Loh, M. M., Houseman, E. A., Gray, G. M., Levy, J. I., Spengler, J. D., & Bennett, D. H.
- Affiliations
- Harvard University (US)
- Corresponding author
- Loh, Miranda M.
- ORCID
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-19
- Volume
- 40
- Issue
- 22
- Pages
- 6903-6911
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1991460767
- Cited by
- 71
- References
- 28
- Citations by year
- 2026: 1 · 2025: 2 · 2023: 1 · 2022: 5 · 2021: 4 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 4 · 2014: 6 · 2013: 6 · 2012: 4
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Environmental Protection Agency
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Toxic Organic Pollutants Impact
- Keywords
- volatile organic compounds, indoor air quality, stores, restaurants, transportation, formaldehyde, toluene, ethylbenzene, xylene, styrene, benzene, chloroform, smoking, occupational exposure, beam studies
- MeSH terms
- Environmental Exposure, Organic Chemicals, Restaurants, Transportation, United States, Volatilization, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.