Visualizing the Uptake of C60 to the Cytoplasm and Nucleus of Human Monocyte-Derived Macrophage Cells Using Energy-Filtered Transmission Electron Microscopy and Electron Tomography
The DOI matches its Crossref record.
Abstract
Concerns have been raised over the release of C60 nanoparticles into the environment and the potential risk to human health. To address these concerns it is essential to understand the pathways by which nanoparticles enter the cell, where they migrate to, and to establish whether the particles are transformed or modified within the cell. Imaging the subcellular distribution of carbon-based nanoparticles is particularly challenging. It is difficult to achieve high spatial resolution with sufficient image contrast to enable the nanoparticles to be identified within the cell. We have exposed human monocyte-derived macrophages (HMMs) to C60 and used energy filtered transmission electron microscopy (EFTEM) to image the distribution of C60 aggregates within intracellular compartments. We demonstrate that images recorded using low-loss electrons provide a significant improvement in contrast between the cellular material and the C60 allowing a clear differentiation between C60 and unstained cellular compartments and also between ordered and disordered forms of aggregated C60. We confirm that C60 is taken up by HMMs in vitro and is sequestered at several sites within the cell. These sites include the cytoplasm, lysosomes, and most significantly the cell nuclei.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New Generation Adsorbents for Water Treatment
Ali, I. (2012) · Chemical Reviews · doi:10.1021/cr300133d · Cited by 1,758
Direct imaging of single-walled carbon nanotubes in cells
Porter, A. E., Gass, M., Muller, K., Skepper, J. N., Midgley, P. A., & Welland, M. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.347 · Cited by 564
“Previously we have demonstrated that low-loss energy-filtered transmission electron microscopy (EFTEM) enables clear differentiation between C 60 and cellular compartments in unstained section”
BackgroundSelf-citationLimbach, L. K., Bereiter, R., Müller, E., Krebs, R., Gälli, R., & Stark, W. J. (2008) · Environmental Science & Technology · doi:10.1021/es800091f · Cited by 480
Biomedical potential of the reactive oxygen species generation and quenching by fullerenes (C60)
Markovic, Z., & Trajkovic, V. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.005 · Cited by 467
Toxicity assessment of nanomaterials: methods and challenges
Dhawan, A., & Sharma, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3996-x · Cited by 466
Metadata
- Authors
- Porter, A. E., Gass, M., Muller, K., Skepper, J. N., Midgley, P., & Welland, M.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-28
- Volume
- 41
- Issue
- 8
- Pages
- 3012-3017
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2035440283
- Cited by
- 116
- References
- 0
- FWCI
- 7.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visualizing the Uptake of C60 to the Cytoplasm and Nucleus of Human Monocyte-Derived Macrophage Cells Using Energy-Filtered Transmission Electron Microscopy and Electron Tomography. https://app.cochat.ai/papers/10.1021/es062541f
- The paper
- Porter, A. E., Gass, M., Muller, K., Skepper, J. N., Midgley, P., & Welland, M. (2007). Visualizing the Uptake of C60 to the Cytoplasm and Nucleus of Human Monocyte-Derived Macrophage Cells Using Energy-Filtered Transmission Electron Microscopy and Electron Tomography. Environmental Science & Technology. https://doi.org/10.1021/es062541f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.