Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 307

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Formation of Toxic Iodinated Disinfection By-Products from Compounds Used in Medical Imaging

Duirk, Stephen E., Lindell, Cristal, Cornelison, Christopher C., Kormos, Jennifer, Ternes, Thomas A., Attene-Ramos, Matias, Osiol, Jennifer, Wagner, Elizabeth D., Plewa, Michael J., Richardson, Susan D.·2011·Environmental Science & Technology

Abstract

Iodinated X-ray contrast media (ICM) were investigated as a source of iodine in the formation of iodo-trihalomethane (iodo-THM) and iodo-acid disinfection byproducts (DBPs), both of which are highly genotoxic and/or cytotoxic in mammalian cells. ICM are widely used at medical centers to enable imaging of soft tissues (e.g., organs, veins, blood vessels) and are designed to be inert substances, with 95% eliminated in urine and feces unmetabolized within 24 h. ICM are not well removed in wastewater treatment plants, such that they have been found at elevated concentrations in rivers and streams (up to 100 μg/L). Naturally occurring iodide in source waters is believed to be a primary source of iodine in the formation of iodo-DBPs, but a previous 23-city iodo-DBP occurrence study also revealed appreciable levels of iodo-DBPs in some drinking waters that had very low or no detectable iodide in their source waters. When 10 of the original 23 cities' source waters were resampled, four ICM were found--iopamidol, iopromide, iohexol, and diatrizoate--with iopamidol most frequently detected, in 6 of the 10 plants sampled, with concentrations up to 2700 ng/L. Subsequent controlled laboratory reactions of iopamidol with aqueous chlorine and monochloramine in the absence of natural organic matter (NOM) produced only trace levels of iodo-DBPs; however, when reacted in real source waters (containing NOM), chlorine and monochloramine produced significant levels of iodo-THMs and iodo-acids, up to 212 nM for dichloroiodomethane and 3.0 nM for iodoacetic acid, respectively, for chlorination. The pH behavior was different for chlorine and monochloramine, such that iodo-DBP concentrations maximized at higher pH (8.5) for chlorine, but at lower pH (6.5) for monochloramine. Extracts from chloraminated source waters with and without iopamidol, as well as from chlorinated source waters with iopamidol, were the most cytotoxic samples in mammalian cells. Source waters with iopamidol but no disinfectant added were the least cytotoxic. While extracts from chlorinated and chloraminated source waters were genotoxic, the addition of iopamidol enhanced their genotoxicity. Therefore, while ICM are not toxic in themselves, their presence in source waters may be a source of concern because of the formation of highly toxic iodo-DBPs in chlorinated and chloraminated drinking water.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es200983f

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 307

Metadata

Authors
Duirk, S. E., Lindell, C., Cornelison, C. C., Kormos, J., Ternes, T. A., Attene-Ramos, M., Osiol, J., Wagner, E. D., Plewa, M. J., & Richardson, S. D.
Venue
Environmental Science & Technology
Published
2011-07-15
Volume
45
Issue
16
Pages
6845-6854
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2074417542
Cited by
307
References
29
FWCI
8.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Formation of Toxic Iodinated Disinfection By-Products from Compounds Used in Medical Imaging. https://app.cochat.ai/papers/10.1021/es200983f
The paper
Duirk, S. E., Lindell, C., Cornelison, C. C., Kormos, J., Ternes, T. A., Attene-Ramos, M., Osiol, J., Wagner, E. D., Plewa, M. J., & Richardson, S. D. (2011). Formation of Toxic Iodinated Disinfection By-Products from Compounds Used in Medical Imaging. Environmental Science & Technology. https://doi.org/10.1021/es200983f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.