The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Porous Substoichiometric TiO2 Anodes as Reactive Electrochemical Membranes for Water Treatment
Abstract
This research investigates the characterization and testing of an anodic reactive electrochemical membrane (REM) for water treatment. The REM consists of a porous substoichiometric titanium dioxide (Ti4O7) tubular, ceramic electrode operated in cross-flow filtration mode. Advection-enhanced mass transfer rates, on the order of a 10-fold increase, are obtained when the REM is operated in filtration-mode, relative to a traditional flow-through mode. Oxidation experiments with model organic compounds showed that the REM was active for both direct oxidation reactions and formation of hydroxyl radicals (OH(•)). Electrochemical impedance spectroscopy data interpreted by transmission line modeling determined that the electro-active surface area was 619 times the nominal geometric surface area. Results from filtration-mode experiments with p-methoxyphenol indicate that compound removal occurred by electro-assisted adsorption and subsequent oxidation. Electro-assisted adsorption was the primary removal mechanism at potentials where OH(•) did not form. At higher potentials (>2.0 V), where OH(•) concentrations were significant, p-methoxyphenol removal occurred by a combination of electro-assisted adsorption and OH(•) oxidation. These removal mechanisms resulted in 99.9% p-methoxyphenol removal in the permeate, with calculated current efficiencies >73% at applied current densities of 0.5-1.0 mA cm(-2). These results illustrate the extreme promise of the REM for water treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Eberson, L. (1992) · J. Chem. Soc., Perkin Trans. 2 · doi:10.1039/p29920001807 · Cited by 57
Cited by
Moreira, F. C., Boaventura, R. A. R., Brillas, E., & Vilar, V. J. P. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.08.037 · Cited by 2,144
Ganiyu, S. O., van Hullebusch, E. D., Cretin, M., Esposito, G., & Oturan, M. A. (2015) · Separation and Purification Technology · doi:10.1016/j.seppur.2015.09.059 · Cited by 627
Electrified Membranes for Water Treatment Applications
Sun, M., Wang, X., Winter, L. R., Zhao, Y., Ma, W., Hedtke, T., Kim, J.-H., & Elimelech, M. (2021) · ACS ES&T Engineering · doi:10.1021/acsestengg.1c00015 · Cited by 320
Hydroxyl radicals in anodic oxidation systems: generation, identification and quantification
Xie, J., Zhang, C., & Waite, T. D. (2022) · Water Research · doi:10.1016/j.watres.2022.118425 · Cited by 303
Electro-oxidation of organic pollutants by reactive electrochemical membranes
Trellu, C., Chaplin, B. P., Coetsier, C., Esmilaire, R., Cerneaux, S., Causserand, C., & Cretin, M. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.05.026 · Cited by 282
Self-citationPan, Z., Song, C., Li, L., Wang, H., Pan, Y., Wang, C., Li, J., Wang, T., & Feng, X. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.01.188 · Cited by 266
Metadata
- Authors
- Zaky, A. M., & Chaplin, B. P.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-05
- Volume
- 47
- Issue
- 12
- Pages
- 6554-6563
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2335434040
- Cited by
- 333
- References
- 2
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.