CoChat

Stability of Amine-Functionalized Cellulose during Temperature-Vacuum-Swing Cycling for CO2 Capture from Air

Gebald, Christoph, Wurzbacher, Jan A., Tingaut, Philippe, Steinfeld, Aldo · 2013 · Environmental Science & Technology
Cited by 152

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The stability of amine-functionalized nanofibrilated cellulose sorbent for direct air capture of CO2 is investigated during temperature-vacuum-swing (TVS) cycling. The presence of O2 at 90 °C degrades the sorbent, reducing its CO2 adsorption capacity by 30% after 15 h of treatment in moist air with a dew point of 22 °C. In contrast, exposure to moist CO2 at 90 °C with a dew point of 22 °C does not deteriorate its CO2 adsorption capacity after 15 h. Performing 100 TVS consecutive cycles, with CO2 adsorption from ambient air containing 400-530 ppm CO2 at 30 °C and 60% relative humidity and with CO2 desorption at 90 °C and 30 mbar, resulted in a reduction of the equilibrium CO2 adsorption capacity by maximum 5%. The average CO2 adsorption capacity during TVS cyclic operation is 0.90 mmol CO2/g.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es401731p

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 152

Metadata

Authors
Gebald, C., Wurzbacher, J. A., Tingaut, P., & Steinfeld, A.
Venue
Environmental Science & Technology
Published
2013-08-21
Volume
47
Issue
17
Pages
10063-10070
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2088638008
Cited by
152
References
3
FWCI
12.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.