Halogenated Volatile Organic Compounds from the Use of Chlorine-Bleach-Containing Household Products
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Sodium hypochlorite (NaOCl) and many organic chemicals contained in household cleaning products may react to generate halogenated volatile organic compounds (VOCs). Halogenated VOC emissions from eight different chlorine bleach containing household products (pure and diluted) were investigated by headspace experiments. Chloroform and carbon tetrachloride were the leading compounds along with several halogenated compounds in the headspace of chlorine bleach products. One of the most surprising results was the presence of carbon tetrachloride (a probable human carcinogen and a powerful greenhouse gas that was banned for household use by the U.S. Food and Drug Administration) in very high concentrations (up to 101 mg m(-3)). By mixing surfactants or soap with NaOCl, it was shown that the formation of carbon tetrachloride and several other halogenated VOCs is possible. In addition to quantitatively determined halogenated VOCs (n = 15), several nitrogen-containing (n = 4), chlorinated (n = 10), oxygenated compounds (n = 22), and hydrocarbons (n = 14) were identified in the headspace of bleach products. Among these, 1,1-dichlorobutane and 2-chloro-2-nitropropane were the most abundant chlorinated VOCs, whereas trichloronitromethane and hexachloroethane were the most frequently detected ones. Indoor air halogenated VOC concentrations resulting from the use of four selected household products were also measured before, during, and 30 min after bathroom, kitchen, and floor cleaning applications. Chloroform (2.9-24.6 microg m(-3)) and carbon tetrachloride (0.25-459 microg m(-3)) concentrations significantly increased during the use of bleach containing products. During/ before concentration ratios ranged between 8 and 52 (25 +/- 14, average +/- SD) for chloroform and 1-1170 (146 +/- 367, average +/- SD) for carbon tetrachloride, respectively. These results indicated that the bleach use can be important in terms of inhalation exposure to carbon tetrachloride, chloroform and several other halogenated VOCs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A large amount of bleach were used for laundry and room cleaning, suggesting the importance of this source [10, 68] and possibly tap water, which frequently contains chloroform as a disinfection byproduct [69].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [69]
Citations
Cites
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Drowning in disinfection byproducts? Assessing swimming pool water
Zwiener, C., Richardson, S. D., De Marini, D. M., Grummt, T., Glauner, T., & Frimmel, F. H. (2007) · Environmental Science & Technology · doi:10.1021/es062367v · Cited by 380
Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Doherty, R. E. (2000) · Environmental Forensics · doi:10.1006/enfo.2000.0010 · Cited by 287
Dincer, F., Odabasi, M., & Muezzinoglu, A. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.075 · Cited by 195
Fiss, E. M., Wigginton, K. R., & Vikesland, P. J. (2007) · Environmental Science & Technology · doi:10.1021/es062227l · Cited by 157
ATSDR (Agency for Toxic Substances and Disease Registry): medical waste poses no threat to public.
Pc, R. (1990) · PubMed · Cited by 142
Nuckols, J. R., Ashley, D. L., Lyu, C., Gordon, S. M., Hinckley, A. F., & Singer, P. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7141 · Cited by 120
Peng, C., & Batterman, S. (2000) · Journal of Environmental Monitoring · doi:10.1039/b003385p · Cited by 97
Formation and growth of indoor air aerosol particles as a result of d-limonene oxidation
Vartiainen, E., Kulmala, M., Ruuskanen, T. M., Taipale, R., Rinne, J., & Vehkamäki, H. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.07.022 · Cited by 91
Research works printed but not linked: 3
- 1999, Compendium Method TO-17, Determination of Volatile Organic Compounds in Ambient Air Using Active Sampling Onto Sorbent Tubes
- 2006, SemiQuant: New GC/MS Software Approaches to Estimating Compound Quantities
- 2007, EPI Suite Estimation Software
Cited by
Weschler, C. J., & Carslaw, N. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.7b06387 · Cited by 293
Indoor Particulate Matter during HOMEChem: Concentrations, Size Distributions, and Exposures
Patel, S., Sankhyan, S., Boedicker, E. K., DeCarlo, P. F., Farmer, D. K., Goldstein, A. H., Katz, E. F., Nazaroff, W. W., Tian, Y., Vanhanen, J., et al. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c00740 · Cited by 214
The atmospheric chemistry of indoor environments
Abbatt, J. P. D., & Wang, C. (2020) · Environmental Science: Processes & Impacts · doi:10.1039/c9em00386j · Cited by 200
Barro, R., Regueiro, J., Llompart, M., & Garcia-Jares, C. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.10.117 · Cited by 198
Observations and impacts of bleach washing on indoor chlorine chemistry
Wong, J. P. S., Carslaw, N., Zhao, R., Zhou, S., & Abbatt, J. P. D. (2017) · Indoor Air · doi:10.1111/ina.12402 · Cited by 174
Mattila, J. M., Lakey, P. S. J., Shiraiwa, M., Wang, C., Abbatt, J. P. D., Arata, C. M., Goldstein, A. H., Ampollini, L., Katz, E. F., DeCarlo, P. F., et al. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.9b05767 · Cited by 168
Clausen, P. A., Frederiksen, M., Sejbæk, C. S., Sørli, J. B., Hougaard, K. S., Frydendall, K. B., Carøe, T. K., Flachs, E. M., Meyer, H. W., Schlünssen, V., et al. (2020) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2020.113592 · Cited by 169
Biomonitoring of human exposures to chlorinated derivatives and structural analogs of bisphenol A
Andra, S. S., Charisiadis, P., Arora, M., van Vliet‐Ostaptchouk, J. V., & Makris, K. C. (2015) · Environment International · doi:10.1016/j.envint.2015.09.011 · Cited by 140
Guo, L., Jia, S., Diercks, C. S., Yang, X., Alshmimri, S. A., & Yaghi, O. M. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201912579 · Cited by 125
Nazaroff, W. W., & Weschler, C. J. (2020) · Indoor Air · doi:10.1111/ina.12670 · Cited by 124
Singh, D., Kumar, A., Kumar, K., Bupender, S., Mina, U., Singh, B. B., & Jain, V. K. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.08.086 · Cited by 113
Vapor Intrusion Investigations and Decision-Making: A Critical Review
Ma, J., McHugh, T. E., Beckley, L., Lahvis, M. A., DeVaull, G. E., & Jiang, L. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c00225 · Cited by 94
de Blas, M., Navazo, M., Alonso, L., Durana, N., Gómez, M. C., & Iza, J. (2012) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2012.04.003 · Cited by 81
Ongwandee, M., Moonrinta, R., Panyametheekul, S., Tangbanluekal, C., & Morrison, G. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.01.026 · Cited by 85
Magnusson, M. E., Vucko, M. J., Neoh, T. L., & de Nys, R. (2020) · Algal Research · doi:10.1016/j.algal.2020.102065 · Cited by 74
Cleaning products: Their chemistry, effects on indoor air quality, and implications for human health
Salonen, H., Salthammer, T., Castagnoli, E., Täubel, M., & Morawska, L. (2024) · Environment International · doi:10.1016/j.envint.2024.108836 · Cited by 87
Hu, L., Montzka, S. A., Miller, B. R., Andrews, A. E., Miller, J. B., Lehman, S. J., Sweeney, C., Miller, S. M., Thoning, K. W., Siso, C., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522284113 · Cited by 72
Preis, S., Klauson, D., & Gregor, A. (2012) · Journal of Environmental Management · doi:10.1016/j.jenvman.2012.10.042 · Cited by 71
Huang, L., Qian, H., Deng, S., Guo, J., Li, Y., Zhao, W., & Yang, Y. (2018) · Atmospheric Environment · doi:10.1016/j.atmosenv.2018.06.009 · Cited by 67
Inhibition strategies of Listeria monocytogenes biofilms—current knowledge and future outlooks
Oloketuyi, S. F., & Khan, F. (2017) · Journal of Basic Microbiology · doi:10.1002/jobm.201700071 · Cited by 65
Kumar, A., Singh, B. P., Punia, M., Singh, D., Kumar, K., & Jain, V. K. (2014) · Indoor Air · doi:10.1111/ina.12096 · Cited by 61
Mattila, J. M., Arata, C. M., Wang, C., Katz, E. F., Abeleira, A., Zhou, Y. S., Zhou, S., Goldstein, A. H., Abbatt, J. P. D., DeCarlo, P. F., et al. (2020) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.0c00573 · Cited by 60
Lin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
“A large amount of bleach were used for laundry and room cleaning, suggesting the importance of this source [10, 68] and possibly tap water, which frequently contains chloroform as a disinfection byproduct [69].”
Liang, Q., Newman, P. A., Daniel, J. S., Reimann, S., Hall, B. D., Dutton, G. S., & Kuijpers, L. J. M. (2014) · Geophysical Research Letters · doi:10.1002/2014gl060754 · Cited by 58
Odabasi, M., Elbir, T., Dumanoglu, Y., & Sofuoglu, S. C. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.04.049 · Cited by 57
Cordier, S., Garlantézec, R., Labat, L., Rouget, F., Monfort, C., Bonvallot, N., Roig, B., Pulkkinen, J. T., Chevrier, C., & Multigner, L. (2012) · Epidemiology · doi:10.1097/ede.0b013e31826c2bd8 · Cited by 57
Denim processing and health hazards
Periyasamy, A. P., & Militký, J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-102043-2.00007-1 · Cited by 57
Volatile and semi-volatile organic compounds of respiratory health relevance in French dwellings
Dallongeville, A., Costet, N., Zmirou‐Navier, D., Bot, B. L., Chevrier, C., Deguen, S., Annesi‐Maesano, I., & Blanchard, O. (2015) · Indoor Air · doi:10.1111/ina.12225 · Cited by 56
Portable GC/MS Methods to Evaluate Sources of cVOC Contamination in Indoor Air
Gorder, K. A., & Dettenmaier, E. M. (2011) · Groundwater Monitoring & Remediation · doi:10.1111/j.1745-6592.2011.01357.x · Cited by 54
Milillo, S. R., Martin, E. M., Muthaiyan, A., & Ricke, S. C. (2011) · Applied and Environmental Microbiology · doi:10.1128/aem.02839-10 · Cited by 53
Recovering PHA from mixed microbial biomass: Using non-ionic surfactants as a pretreatment step
Colombo, B., Pereira, J., Martins, M., Torres-Acosta, M. A., Dias, A., Lemos, P., Ventura, S. P., Eisele, G., Alekseeva, A., Adani, F., et al. (2020) · Separation and Purification Technology · doi:10.1016/j.seppur.2020.117521 · Cited by 40
Slezáková, K., Peixoto, C., Pereira, M. D. C., & Morais, S. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.07.015 · Cited by 47
Caron-Beaudoin, É., Whyte, K. P., Bouchard, M. F., Chevrier, J., Haddad, S., Copes, R., Frohlich, K. L., Dokkie, D., Juul, S., Bouchard, M., et al. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.150242 · Cited by 47
Su, F.-C., Friesen, M. C., Stefaniak, A. B., Henneberger, P. K., LeBouf, R. F., Stanton, M. L., Liang, X., Humann, M., & Virji, M. A. (2018) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxy055 · Cited by 46
Household Cleaning Activities as Noningestion Exposure Determinants of Urinary Trihalomethanes
Charisiadis, P., Andra, S. S., Makris, K. C., Christodoulou, M., Christophi, C. A., Kargaki, S., & Stephanou, E. G. (2013) · Environmental Science & Technology · doi:10.1021/es404220z · Cited by 46
Quirós-Alcalá, L., Wilson, S., Witherspoon, N. O., Murray, R., Pérodin, J., Trousdale, K., Raspanti, G., & Sapkota, A. (2015) · Environmental Research · doi:10.1016/j.envres.2015.12.005 · Cited by 49
Chen, R., Li, T., Huang, C., Yu, Y., Zhou, L., Hu, G., Yang, F., & Zhang, L. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.117893 · Cited by 44
Garlantézec, R., Multigner, L., Labat, L., Bonvallot, N., Pulkkinen, J. T., Dananché, B., Monfort, C., Rouget, F., & Cordier, S. (2011) · Occupational and Environmental Medicine · doi:10.1136/oem.2010.062315 · Cited by 41
Australian carbon tetrachloride emissions in a global context
Fraser, P. J., Dunse, B. L., Manning, A. J., Walsh, S., Wang, R. H. J., Krummel, P. B., Steele, L. P., Porter, L. W., Allison, C. E., O’Doherty, S., et al. (2014) · Environmental Chemistry · doi:10.1071/en13171 · Cited by 39
Hydrogen Peroxide Emission and Fate Indoors during Non-bleach Cleaning: A Chamber and Modeling Study
Zhou, S., Liu, Z., Wang, Z., Young, C. J., VandenBoer, T. C., Guo, B. B., Zhang, J. “., Carslaw, N., & Kahan, T. F. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c04702 · Cited by 39
Lou, J., Wang, W., Lü, H., Wang, L., & Zhu, L. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126249 · Cited by 37
Volatile organic compounds emitted by conventional and “green” cleaning products in the U.S. market
Temkin, A. M., Geller, S. L., Swanson, S. A., Leiba, N. S., Naidenko, O. V., & Andrews, D. Q. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.139570 · Cited by 37
Environmental benefits of macroalgae products: A case study of agar based on life cycle assessment
Zhang, R., Wang, Q., Shen, H., Yang, Y., Liu, P., & Dong, Y. (2024) · Algal Research · doi:10.1016/j.algal.2023.103384 · Cited by 36
Guo, L., Jia, S., Diercks, C. S., Yang, X., Alshmimri, S. A., & Yaghi, O. M. (2019) · Angewandte Chemie · doi:10.1002/ange.201912579 · Cited by 36
Beckley, L., Gorder, K. A., Dettenmaier, E. M., Rivera‐Duarte, I., & McHugh, T. E. (2014) · Environmental Forensics · doi:10.1080/15275922.2014.930941 · Cited by 35
Adjei, J. K., Ofori, A., Megbenu, H. K., Ahenguah, T., Boateng, A. K., Adjei, G., Bentum, J. K., & Essumang, D. K. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.149008 · Cited by 39
Carter, J. M., Moran, M. J., Zogorski, J. S., & Price, C. V. (2012) · Environmental Science & Technology · doi:10.1021/es301839p · Cited by 32
Biocides overview and applications in petroleum microbiology
Keasler, V. V., de Paula, R. M., Nilsen, G., Grunwald, L., & Tidwell, T. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-101105-8.00023-1 · Cited by 32
Sarkar, C., Chatterjee, A., Majumdar, D., Ghosh, S. K., Srivastava, A. K., & Raha, S. (2014) · doi:10.5194/acpd-14-32133-2014 · Cited by 32
Ding, X., Lu, H., Jiang, J., Tasoglou, A., Shah, A. D., & Jung, N. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110953 · Cited by 31
Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex
McHugh, T. E., Beckley, L., Sullivan, T. M., Lutes, C. C., Truesdale, R. S., Uppencamp, R., Cosky, B., Zimmerman, J. H., & Schumacher, B. A. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.04.135 · Cited by 29
Respiratory Health Effects of Exposure to Cleaning Products
Matteis, S. D., Ronsmans, S., & Nemery, B. (2020) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2020.08.010 · Cited by 31
Are Disinfectants for the Prevention and Control of COVID-19 Safe?
Samara, F., Badran, R., & Dalibalta, S. (2020) · Health Security · doi:10.1089/hs.2020.0104 · Cited by 29
Harley, K. G., Calderon, L. E., Nolan, J. E. S., Maddalena, R. L., Russell, M., Roman, K., Mayo-Burgos, S., Cabrera, J. J., Morga, N., & Bradman, A. (2021) · Environmental Health Perspectives · doi:10.1289/ehp8831 · Cited by 29
Asif, Z., Chen, Z., Haghighat, F., Nasiri, F., & Dong, J. (2022) · Environmental Management · doi:10.1007/s00267-022-01732-6 · Cited by 29
Kalyvas, H., Andra, S. S., Charisiadis, P., Karaolis, C., & Makris, K. C. (2014) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2014.04.072 · Cited by 28
Szczuka, A., Chuang, Y.-H. B., Chen, F. C., Zhang, Z., Desormeaux, E., Flynn, M., Parodi, J., & Mitch, W. A. (2020) · ACS ES&T Water · doi:10.1021/acsestwater.0c00006 · Cited by 26
Environmental method for spectrophotometric determination of copper(II)
Hashem, E. Y., Seleim, M. M., & El‐Zohry, A. M. (2011) · Green Chemistry Letters and Reviews · doi:10.1080/17518253.2010.546370 · Cited by 26
IRRITANT COMPOUNDS: RESPIRATORY IRRITANT GASES
Patočka, J., & Kuča, K. (2014) · Military Medical Science Letters · doi:10.31482/mmsl.2014.012 · Cited by 31
Chang, C., Kao, Y.-C., Chen, J.-K., Zhang, H.-C., & Wu, S. (2023) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2023.04.035 · Cited by 25
Andra, S. S., Charisiadis, P., Karakitsios, S., Sarigiannis, D. A., & Makris, K. C. (2014) · Environmental Research · doi:10.1016/j.envres.2014.10.018 · Cited by 23
Calderon, L. E., Maddalena, R. L., Russell, M., Chen, S., Nolan, J. E. S., Bradman, A., & Harley, K. G. (2022) · Indoor Air · doi:10.1111/ina.13162 · Cited by 24
A BODIPY Based Fluorescent Probe for the Rapid Detection of Hypochlorite
Wang, L., Li, B., Jiang, C., Sun, R., Hu, P., Chen, S., & Wu, W. (2018) · Journal of Fluorescence · doi:10.1007/s10895-018-2255-y · Cited by 23
Near-source hypochlorous acid emissions from indoor bleach cleaning
Stubbs, A. D., Lao, M., Wang, C., Abbatt, J. P. D., Hoffnagle, J. A., VandenBoer, T. C., & Kahan, T. F. (2023) · Environmental Science Processes & Impacts · doi:10.1039/d2em00405d · Cited by 26
Applying the precautionary principle to consumer household cleaning product development
Bondi, C. A. M. (2010) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2010.07.008 · Cited by 25
House-plant placement for indoor air purification and health benefits on asthmatics
Kim, H.-H., Yang, J.-Y., Lee, J., Park, J., Kim, K. J., Lim, B.-S., Lee, G.-W., Lee, S.-E., Shin, D.-C., & Lim, Y.-W. (2014) · Environmental Health and Toxicology · doi:10.5620/eht.e2014014 · Cited by 21
Chemical composition of household malodours – an overview
Hammond, C. J. (2013) · Flavour and Fragrance Journal · doi:10.1002/ffj.3163 · Cited by 21
Warburton, T., Hamilton, J. F., Carslaw, N., McEachan, R., Yang, T., Hopkins, J. R., Andrews, S., & Lewis, A. C. (2025) · Environmental Science Processes & Impacts · doi:10.1039/d4em00756e · Cited by 20
Indoor cooking and cleaning as a source of outdoor air pollution in urban environments
Carter, T. J., Shaw, D. R., Carslaw, D. C., & Carslaw, N. (2024) · Environmental Science Processes & Impacts · doi:10.1039/d3em00512g · Cited by 25
McMahon, P. B., Galloway, J. M., Hunt, A. G., Belitz, K., Jurgens, B. C., & Johnson, T. D. (2020) · Applied Geochemistry · doi:10.1016/j.apgeochem.2020.104833 · Cited by 20
Bamiduro, G. J., & Zahran, E. M. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c11929 · Cited by 19
Çapan, R., Çapan, İ., & Bayrakcı, M. (2024) · ACS Applied Polymer Materials · doi:10.1021/acsapm.4c00909 · Cited by 19
Consumer products as sources of chemical exposures to children: case study of triclosan
Ginsberg, G. L., & Balk, S. J. (2016) · Current Opinion in Pediatrics · doi:10.1097/mop.0000000000000329 · Cited by 18
Chloroform—An Emerging Pollutant in the Air
Sekar, A., Varghese, G. K., & Varma, M. K. R. (2021) · Energy, environment, and sustainability · doi:10.1007/978-981-16-8367-1_6 · Cited by 21
Peroxodicarbonate: Electrosynthesis and first directions to green industrial applications
Ziogas, A., Belda, J., Kost, H.-J., Magomajew, J., Sperling, R. A., & Wernig, P. (2022) · Current Research in Green and Sustainable Chemistry · doi:10.1016/j.crgsc.2022.100341 · Cited by 17
Dye Decolorization by a Miniaturized Peroxidase Fe-MimochromeVI*a
Chino, M., Gatta, S. L., Leone, L., Fenza, M. D., Lombardi, A., Pavone, V., & Maglio, O. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241311070 · Cited by 17
García-Jares, C., Barro, R., & Llompart, M. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00008-9 · Cited by 17
Kwon, J., Weisel, C. P., Morandi, M. T., & Stock, T. H. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.08.186 · Cited by 17
Rago, R., Rezendes, A., Peters, J., Kelly Chatterton, B. S., & Kammari, A. (2021) · Groundwater Monitoring & Remediation · doi:10.1111/gwmr.12433 · Cited by 17
Formation of organochlorine by-products in bleached laundry
Leri, A. C., & Anthony, L. N. (2012) · Chemosphere · doi:10.1016/j.chemosphere.2012.10.088 · Cited by 17
Lin, N., Ding, N., Meza‐Wilson, E., Devasurendra, A. M., Godwin, C., Park, S. K., & Batterman, S. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c02862 · Cited by 16
Liang, Z., Tu, X., Liu, H., Zhang, K., Pan, Q., He, X., Jia, Y., & Sang, Y. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.137456 · Cited by 15
Sweet, N. M., Lunderberg, D. M., Molinier, B., Pfannerstill, E. Y., Katz, E. F., Misztal, P. K., Liu, Y. J., Arata, C. M., Kristensen, K. V., Tian, Y., et al. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.4c11274 · Cited by 15
Nie, Y., Wang, S., Lin, Y., Lai, W., Weng, W., & Tang, D. (2020) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.119231 · Cited by 15
Exposure Routes and Types of Exposure
Feld-Cook, E., & Weisel, C. P. (2021) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_38-1 · Cited by 16
Development and validation of a new in situ technique to measure total gaseous chlorine in air
Furlani, T. C., Ye, R., Stewart, J., Crilley, L. R., Edwards, P. M., Kahan, T. F., & Young, C. J. (2023) · Atmospheric measurement techniques · doi:10.5194/amt-16-181-2023 · Cited by 15
Bioimaging of a chromenoquinoline-based ratiometric fluorescent probe for detecting ClO−
Shangguan, H., Liu, Q., Wang, Y., Teng, Z., Tian, R., Wu, T., Yang, L., Jiang, L., Liu, X., & Wei, L. (2023) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2023.123256 · Cited by 12
Doucette, W. J., Wetzel, T. A., Dettenmaier, E. M., & Gorder, K. A. (2018) · Environmental Forensics · doi:10.1080/15275922.2018.1475433 · Cited by 12
Gui, C., Song, M., Liu, Q., Xiang, D., Lu, P., Fourmentin, S., Hua, C., & Lei, Z. (2025) · AIChE Journal · doi:10.1002/aic.18858 · Cited by 11
Assessing environmental and occupational risk factors for lung cancer in Mexican–Americans
McHugh, M. K., Kachroo, S., Liu, M., D'amelio, A. M., Dong, Q., Hong, W. K., Greisinger, A. J., Spitz, M. R., & Etzel, C. J. (2010) · Cancer Causes & Control · doi:10.1007/s10552-010-9635-1 · Cited by 11
Bleaching Agents: A Review of Their Utilization and Management
Kulkarni, D., Jaspal, D. K., Itankar, N., Petrounias, P., Rogkala, A., & Lampropoulou, P. (2024) · Sustainability · doi:10.3390/su16209084 · Cited by 11
Bleach Emissions Interact Substantially with Surgical and KN95 Mask Surfaces
Bhattacharyya, N., Tang, M., Blomdahl, D. C., Jahn, L. G., Abue, P., Allen, D. T., Corsi, R. L., Novoselac, A., Misztal, P. K., & Ruiz, L. H. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.2c07937 · Cited by 10
Shin, H., & Lim, H. (2017) · Chemosphere · doi:10.1016/j.chemosphere.2017.01.090 · Cited by 10
de Blas, M., Uria, I., Gómez, M. C., Navazo, M., Alonso, L., Fernández, G., Durana, N., Iza, J., & Valencia, J. D. R. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.03.177 · Cited by 9
Mayer, A., & Miskelly, G. M. (2022) · Forensic Chemistry · doi:10.1016/j.forc.2022.100399 · Cited by 9
Inhalation and Skin Exposure to Chemicals in Hospital Settings
Virji, M. A., Bowers, L. N., & LeBouf, R. F. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_60-1 · Cited by 10
Combination of Surfactant Action with Peroxide Activation for Room‐Temperature Cleaning of Textiles
Shao, D., Liu, G., Chen, H., Xu, C., & Du, J. (2020) · Journal of Surfactants and Detergents · doi:10.1002/jsde.12471 · Cited by 9
Exposure of cleaning workers to chemical agents and physical conditions in swimming pools and spas
Ruokolainen, J., Hyttinen, M., Sorvari, J., & Pasanen, P. O. (2021) · Air Quality Atmosphere & Health · doi:10.1007/s11869-021-01138-z · Cited by 9
Xiang, Y., & Xu, H. Y. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.140182 · Cited by 8
Peixoto, C., Pereira, M. D. C., Morais, S., & Slezáková, K. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1310215 · Cited by 8
Metadata
- Authors
- Odabasi, M.
- Affiliations
- Department of Environmental Engineering, Faculty of Engineering, Dokuz Eylul University, Kaynaklar Campus, 35160 Buca, Izmir, Turkey
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-01
- Volume
- 42
- Issue
- 5
- Pages
- 1445-1451
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2114378216
- Cited by
- 159
- References
- 13
- Citations by year
- 2026: 1 · 2025: 13 · 2024: 8 · 2023: 23 · 2022: 15 · 2021: 10 · 2020: 18 · 2019: 5 · 2018: 7 · 2017: 8 · 2016: 8 · 2015: 6 · 2014: 13 · 2013: 3 · 2012: 8
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Environmental Science & Technology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Food and Drug Administration
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Keywords
- halogenated volatile organic compounds, chlorine bleach, household cleaning products, sodium hypochlorite, carbon tetrachloride, chloroform, indoor air quality, inhalation exposure, chloropicrin, hexachloroethane
- MeSH terms
- Halogens, Household Products, Organic Chemicals, Quality Control, Sodium Hypochlorite, Volatilization, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.