The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Coating Fe3O4 Magnetic Nanoparticles with Humic Acid for High Efficient Removal of Heavy Metals in Water
Open accessAbstract
Humic acid (HA) coated Fe3O4 nanoparticles (Fe3O4/HA) were developed for the removal of toxic Hg(II), Pb(II), Cd(II), and Cu(II) from water. Fe3O4/HA were prepared by a coprecipitation procedure with cheap and environmentally friendly iron salts and HA. TOC and XPS analysis showed the as-prepared Fe3O4/HA contains approximately 11% (w/w) of HA which are fractions abundant in O and N-based functional groups. TEM images and laser particle size analysis revealed the Fe3O4/HA (with approximately 10 nm Fe3O4 cores) aggregated in aqueous suspensions to form aggregates with an average hydrodynamic size of approximately 140 nm. With a saturation magnetization of 79.6 emu/g, the Fe3O4/HA can be simply recovered from water with magnetic separations at low magnetic field gradients within a few minutes. Sorption of the heavy metals to Fe3O4/HA reached equilibrium in less than 15 min, and agreed well to the Langmuir adsorption model with maximum adsorption capacities from 46.3 to 97.7 mg/g. The Fe3O4/HA was stable in tap water, natural waters, and acidic/ basic solutions ranging from 0.1 M HCl to 2 M NaOH with low leaching of Fe (< or = 3.7%) and HA (< or = 5.3%). The Fe3O4/HA was able to remove over 99% of Hg(ll) and Pb(ll) and over 95% of Cu(II) and Cd(II) in natural and tap water at optimized pH. Leaching back of the Fe3O4/HA sorbed heavy metals in water was found to be negligible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative assessment of worldwide contamination of air, water and soils by trace metals
Nriagu, J. O., & Pacyna, J. M. (1988) · Nature · doi:10.1038/333134a0 · Cited by 4,368
(2003) · Elsevier eBooks · doi:10.1016/b978-0-12-656446-4.x5000-2 · Cited by 2,575
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Self‐Assembled 3D Flowerlike Iron Oxide Nanostructures and Their Application in Water Treatment
Zhong, L. ‐., Hu, J. ‐., Liang, H. ‐., Cao, A. ‐., Song, W. ‐., & Wan, L. ‐. (2006) · Advanced Materials · doi:10.1002/adma.200600504 · Cited by 1,587
Functionalized Monolayers on Ordered Mesoporous Supports
Feng, X., Fryxell, G. E., Wang, L.-Q., Kim, A. Y., Liu, J., & Kemner, K. M. (1997) · Science · doi:10.1126/science.276.5314.923 · Cited by 1,562
Self-citationAdsorption and desorption of natural organic matter on iron oxide: mechanisms and models
Gu, B., Schmitt, J., Chen, Z., Liang, L., & McCarthy, J. F. (1994) · Environmental Science & Technology · doi:10.1021/es00050a007 · Cited by 1,448
Low-Field Magnetic Separation of Monodisperse Fe 3 O 4 Nanocrystals
Yavuz, C. T., Mayo, J. T., Yu, W. W., Prakash, A., Falkner, J. C., Yean, S., Cong, L., Shipley, H. J., Kan, A., Tomson, M., et al. (2006) · Science · doi:10.1126/science.1131475 · Cited by 1,250
Nanomaterials and Water Purification: Opportunities and Challenges
Savage, N., & Diallo, M. S. (2005) · Journal of Nanoparticle Research · doi:10.1007/s11051-005-7523-5 · Cited by 1,221
Remediation of Cr(VI) and Pb(II) Aqueous Solutions Using Supported, Nanoscale Zero-valent Iron
Ponder, S. M., Darab, J. G., & Mallouk, T. E. (2000) · Environmental Science & Technology · doi:10.1021/es9911420 · Cited by 1,209
Adsorption of Several Metal Ions onto a Low-Cost Biosorbent: Kinetic and Equilibrium Studies
Reddad, Z., Gerente, C., Andres, Y., & Le Cloirec, P. (2002) · Environmental Science & Technology · doi:10.1021/es0102989 · Cited by 1,201
Removal and recovery of Cr(VI) from wastewater by maghemite nanoparticles
Hu, J., Chen, G., & Lo, I. M. C. (2005) · Water Research · doi:10.1016/j.watres.2005.05.051 · Cited by 1,065
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Chang, Y.-C., & Chen, D.-H. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2004.09.010 · Cited by 723
Yantasee, W., Warner, C. L., Sangvanich, T., Addleman, R. S., Carter, T. G., Wiacek, R. J., Fryxell, G. E., Timchalk, C., & Warner, M. G. (2007) · Environmental Science & Technology · doi:10.1021/es0705238 · Cited by 688
Maity, D., & Agrawal, D. C. (2007) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.05.001 · Cited by 621
Magnetoferritin: in Vitro Synthesis of a Novel Magnetic Protein
Meldrum, F. C., Heywood, B. R., & Mann, S. (1992) · Science · doi:10.1126/science.1636086 · Cited by 572
Illés, E., & Tombácz, E. (2006) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.08.003 · Cited by 567
Metal Ion Binding by Humic Acid: Application of the NICA-Donnan Model
Kinniburgh, D. G., Milne, C. J., Benedetti, M. F., Pinheiro, J. P., Filius, J., Koopal, L. K., & Van Riemsdijk, W. H. (1996) · Environmental Science & Technology · doi:10.1021/es950695h · Cited by 558
Preparation and characterization of amino–silane modified superparamagnetic silica nanospheres
Liu, X., Ma, Z., Xing, J., & Liu, H. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2003.07.006 · Cited by 517
Complexation of trace metals by adsorbed natural organic matter
Davis, J. A. (1984) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(84)90095-4 · Cited by 472
McKnight, D. M., Bencala, K. E., Zellweger, G. W., Aiken, G. R., Feder, G. L., & Thorn, K. A. (1992) · Environmental Science & Technology · doi:10.1021/es00031a017 · Cited by 405
Removal of Heavy Metals from Mine Waters by Natural Zeolites
Wingenfelder, U., Hansen, C., Furrer, G., & Schulin, R. (2005) · Environmental Science & Technology · doi:10.1021/es048482s · Cited by 376
Magnetic nano- and microparticles for metal removal and environmental applications: a review
Ngomsik, A.-F., Bee, A., Draye, M., Cote, G., & Cabuil, V. (2005) · Comptes Rendus. Chimie · doi:10.1016/j.crci.2005.01.001 · Cited by 372
Adsorption of dissolved organics in lake water by aluminum oxide. Effect of molecular weight
Davis, J. A., & Gloor, R. (1981) · Environmental Science & Technology · doi:10.1021/es00092a012 · Cited by 320
Diallo, M. S., Christie, S., Swaminathan, P., Johnson, & Goddard, W. A. (2005) · Environmental Science & Technology · doi:10.1021/es048961r · Cited by 298
ENVIRONMENTAL SOIL CHEMISTRY: AN OVERVIEW
Sparks, D. L. (1995) · Environmental Soil Chemistry · doi:10.1016/b978-0-12-656445-7.50005-x · Cited by 281
Binding of Mercury(II) to Aquatic Humic Substances: Influence of pH and Source of Humic Substances
Haitzer, M., Aiken, G. R., & Ryan, J. N. (2003) · Environmental Science & Technology · doi:10.1021/es026291o · Cited by 261
Removal of Cr(VI) by magnetite
Hu, J., Lo, I. M. C., & Chen, G. (2004) · Water Science and Technology · doi:10.2166/wst.2004.0706 · Cited by 256
Tanaka, T., & Matsunaga, T. (2000) · Analytical Chemistry · doi:10.1021/ac9912505 · Cited by 251
Illés, E., & Tombácz, E. (2003) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2003.09.017 · Cited by 241
Vermeer, A. W. P., McCulloch, J. K., van Riemsdijk, W. H., & Koopal, L. K. (1999) · Environmental Science & Technology · doi:10.1021/es990260k · Cited by 175
Enhanced removal of heavy metal ions bound to humic acid by polyelectrolyte flocculation
Hankins, N. P., Lü, N., & Hilal, N. (2006) · Separation and Purification Technology · doi:10.1016/j.seppur.2005.12.022 · Cited by 135
Adsorption of cadmium and humic acid onto hematite
Davis, A. P., & Bhatnagar, V. (1995) · Chemosphere · doi:10.1016/0045-6535(94)00387-a · Cited by 117
Tunable Biopolymers for Heavy Metal Removal
Košťál, J., Mulchandani, A., & Chen, W. (2001) · Macromolecules · doi:10.1021/ma001973m · Cited by 113
Transport of humic matter-coated hematite in packed beds
Amirbahman, A., & Olson, T. M. (1993) · Environmental Science & Technology · doi:10.1021/es00049a021 · Cited by 102
Cited by
Heavy metal removal from water/wastewater by nanosized metal oxides: A review
Hua, M., Zhang, S., Pan, B., Zhang, W., Lv, L., & Zhang, Q. (2012) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.10.016 · Cited by 2,193
Removal of heavy metals from industrial wastewaters: a review
Azimi, A., Azari, A., Rezakazemi, M., & Ansarpour, M. (2017) · ChemBioEng Reviews · doi:10.1002/cben.201600010 · Cited by 1,267
Ai, L., Zhang, C., Liao, F., Wang, Y., Li, M., Meng, L., & Jiang, J. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.10.041 · Cited by 737
Role of nanomaterials as adsorbents in heavy metal ion removal from waste water: A review
Wadhawan, S., Jain, A., Nayyar, J., & Mehta, S. K. (2020) · Journal of Water Process Engineering · doi:10.1016/j.jwpe.2019.101038 · Cited by 530
Cr(VI) Adsorption and Reduction by Humic Acid Coated on Magnetite
Jiang, W., Cai, Q., Xu, W., Yang, M., Cai, Y., Dionysiou, D. D., & O’Shea, K. E. (2014) · Environmental Science & Technology · doi:10.1021/es405804m · Cited by 462
Metadata
- Authors
- Liu, J.-F., Zhao, Z.-S., & Jiang, G.-B.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-14
- Volume
- 42
- Issue
- 18
- Pages
- 6949-6954
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2070788423
- Cited by
- 1,084
- References
- 36
- FWCI
- 27.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.