Ionic Liquids for Simultaneous Preconcentration of Some Lanthanoids Using Dispersive Liquid−Liquid Microextraction Technique in Uranium Dioxide Powder
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Ionic liquids in a dispersive liquid-liquid microextraction technique were used for determination of lanthanoids such as samarium, europium, gadolinium, and dysprosium in uranium dioxide powder. In this process, an appropriate mixture of extraction solvent and disperser is rapidly injected into an aqueous sample containing samarium, europium, gadolinium, and dysprosium ions complexes with 1-hydroxy-2, 5-pyrrolidinedione, and consequently a cloudy solution is formed. It consists of fine droplets of extraction solventwhich are dispersed entirely into the aqueous phase. After centrifugation of this solution, the whole enriched phase was determined by inductively coupled plasma optical emission spectrometry. In the present work, the preconcentration factor, limit of detection, and relative standard deviation were investigated for samarium, europium, gadolinium, and dysprosium in uranium dioxide powder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Ahmadi, F., Assadi, Y., Hosseini, S. M. R. M., & Rezaee, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.017 · Cited by 325
Cited by
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Ionic Liquids-Based Extraction: A Promising Strategy for the Advanced Nuclear Fuel Cycle
Sun, X., Luo, H., & Dai, S. (2012) · Chemical Reviews · doi:10.1021/cr200193x · Cited by 852
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Metadata
- Authors
- Mallah, M. H., Shemirani, F., & Maragheh, M. G.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-02-12
- Volume
- 43
- Issue
- 6
- Pages
- 1947-1951
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2094682903
- Cited by
- 95
- References
- 4
- FWCI
- 12.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.