The DOI matches its Crossref record.
Effect of Temperature, Ionic Strength, Background Electrolytes, and Fe(III) on the Reduction of Hexavalent Chromium by Soil Humic Substances
Abstract
The rate of hexavalent chromium reduction by soil humic substances (SHSs) was investigated in aqueous solutions where the temperature, ionic strength, background electrolyte, [Fe(III)], and [Cr(III)] were independently varied. Rate experiments were conducted with an excess of SHS over Cr(VI). An Arrenhius plot for the reduction of Cr(VI) by a soil fulvic acid and a soil humic acid indicates that the activation enthalpies for oxidation of these substances are nearly the same (63 ± 1 and 61 ± 3 kJ mol - 1, respectively) and the activation entropies are significantly different (−160 ± 5 and −203 ± 9 J mol - 1 K - 1, respectively). Rates of reduction are not significantly altered due to changes in either background electrolyte or ionic strength. The presence of Cr(III) slightly inhibits the rate of reduction by soil humic acid, but not that of soil fulvic acid. Ferric iron increases the rate of Cr(VI) reduction, even when only a small amount of Fe(III) is added to the system. Fe may enhance the reduction of Cr(VI) by being alternately reduced by the SHS and then oxidized by the Cr(VI) as part of a redox cycle. The reduction of FeCrO 4 + complexes via a parallel reaction pathway may also enhance Cr(VI) reduction in the Cr−Fe−SHS system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chromium isotopes and the fate of hexavalent chromium in the environment
Ellis, A. S., Johnson, T. M., & Bullen, T. D. (2002) · Science · doi:10.1126/science.1068368 · Cited by 492
Cr(VI) Adsorption and Reduction by Humic Acid Coated on Magnetite
Jiang, W., Cai, Q., Xu, W., Yang, M., Cai, Y., Dionysiou, D. D., & O’Shea, K. E. (2014) · Environmental Science & Technology · doi:10.1021/es405804m · Cited by 462
Jiang, B., Gong, Y., Gao, J., Sun, T., Liu, Y., Oturan, N., & Oturan, M. A. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.10.070 · Cited by 365
Influence of Organic Ligands on Chromium(VI) Reduction by Iron(II)
Buerge, I. J., & Hug, S. J. (1998) · Environmental Science & Technology · doi:10.1021/es970932b · Cited by 263
Reinhard, C. T., Planavsky, N. J., Wang, X., Fischer, W. W., Johnson, T. M., & Lyons, T. W. (2014) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2014.09.024 · Cited by 134
Metadata
- Authors
- Wittbrodt, P. R., & Palmer, C. D.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 30
- Issue
- 8
- Pages
- 2470-2477
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2032792737
- Cited by
- 229
- References
- 0
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Temperature, Ionic Strength, Background Electrolytes, and Fe(III) on the Reduction of Hexavalent Chromium by Soil Humic Substances. https://app.cochat.ai/papers/10.1021/es950731c
- The paper
- Wittbrodt, P. R., & Palmer, C. D. (1996). Effect of Temperature, Ionic Strength, Background Electrolytes, and Fe(III) on the Reduction of Hexavalent Chromium by Soil Humic Substances. Environmental Science & Technology. https://doi.org/10.1021/es950731c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.