Solid-Phase Microextraction of Nitrogen- and Phosphorus-Containing Pesticides from Water and Gas Chromatographic Analysis
The DOI matches its Crossref record.
Abstract
Solid-phase microextraction (SPME), a single-step solvent-free extraction, followed by gas−liquid chro matography (GC) employing a nitrogen−phosphorus detector (NPD) and mass spectrometry (MS) was evaluated for the measurement of the 46 nitrogen- and phosphorus-containing pesticides of U.S. EPA Method 507. Effects of pH, ionic strength, methanol content, and temperature on extraction were determined. Analytes were extracted into a bonded polydimethylsiloxane phase coated on a fused-silica fiber and then thermally desorbed in a GC injector and analyzed. Absorption−time and absorption−concentration profiles were obtained for each SPME-extractable pesticide. When analyzed by SPME GC/NPD or by SPME GC/MS, 34 and 39 pesticides, respectively, were measured at levels lower than the EPA method detection limits and precision require ments. This method was applied to the analysis of contaminated well water, watershed, and streamwater and compared to U.S. EPA Method 507 findings. These results demonstrate that SPME is a valuable tool for the rapid screening of 39 EPA Method 507 nitrogen- and phosphorus-containing pesticides in water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Ahmadi, F., Assadi, Y., Hosseini, S. M. R. M., & Rezaee, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.017 · Cited by 325
Solid-phase microextraction in pesticide residue analysis
Beltran, J., López, F. J., & Hernández, F. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00142-4 · Cited by 282
Dispersive liquid–liquid microextraction using extraction solvent lighter than water
Farajzadeh, M. A., Seyedi, S. E., Shalamzari, M. S., & Bamorowat, M. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900109 · Cited by 196
Basheer, C., & Lee, H. K. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.09.083 · Cited by 183
Metadata
- Authors
- Choudhury, T. K., Gerhardt, K. O., & Mawhinney, T. P.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-10-01
- Volume
- 30
- Issue
- 11
- Pages
- 3259-3265
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1996971521
- Cited by
- 84
- References
- 0
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solid-Phase Microextraction of Nitrogen- and Phosphorus-Containing Pesticides from Water and Gas Chromatographic Analysis. https://app.cochat.ai/papers/10.1021/es960040w
- The paper
- Choudhury, T. K., Gerhardt, K. O., & Mawhinney, T. P. (1996). Solid-Phase Microextraction of Nitrogen- and Phosphorus-Containing Pesticides from Water and Gas Chromatographic Analysis. Environmental Science & Technology. https://doi.org/10.1021/es960040w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.