The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Feasibility of Ionic Liquids as Alternative Separation Media for Industrial Solvent Extraction Processes
Abstract
Extraction of rare earth metals into ionic liquids (ILs) from aqueous solutions was investigated using octyl(phenyl)- N, N -diisobutylcarbamoylmethyl phosphine oxide (CMPO) as an extractant. Use of ILs greatly enhanced the extraction efficiency and selectivity of CMPO for metal ions compared to when n -dodecane was used as the extracting solvent. The extraction mechanism has been studied by slope analysis and extraction tests, and these confirmed that the metal extraction proceeds via a cation-exchange mechanism. Furthermore, stripping of metals from ILs into an aqueous phase by complexing agents and recycling of the extracting ILs phase was successfully accomplished.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Room-Temperature Ionic Liquids. Solvents for Synthesis and Catalysis
Welton, T. (1999) · Chemical Reviews · doi:10.1021/cr980032t · Cited by 11,852
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Hydrophobic, Highly Conductive Ambient-Temperature Molten Salts
Bonhôte, P., Dias, A.-P., Papageorgiou, N., Kalyanasundaram, K., & Grätzel, M. (1996) · Inorganic Chemistry · doi:10.1021/ic951325x · Cited by 4,358
Huddleston, J. G., Visser, A. E., Reichert, W. M., Willauer, H. D., Broker, G. A., & Rogers, R. D. (2001) · Green Chemistry · doi:10.1039/b103275p · Cited by 3,712
Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction
Huddleston, J. G., Willauer, H. D., Swatloski, R. P., Visser, A. E., & Rogers, R. D. (1998) · Chem. Commun. · doi:10.1039/a803999b · Cited by 2,167
Ionic Liquids for Clean Technology
Seddon, K. R. (1997) · Journal of Chemical Technology & Biotechnology · doi:10.1002/(sici)1097-4660(199704)68:4<351::aid-jctb613>3.0.co;2-4 · Cited by 2,034
Green processing using ionic liquids and CO2
Blanchard, L. A., Hancu, D., Beckman, E. J., & Brennecke, J. F. (1999) · Nature · doi:10.1038/19887 · Cited by 2,008
Characterizing Ionic Liquids On the Basis of Multiple Solvation Interactions
Anderson, J. L., Ding, J., Welton, T., & Armstrong, D. W. (2002) · Journal of the American Chemical Society · doi:10.1021/ja028156h · Cited by 1,078
Task-specific ionic liquids for the extraction of metal ions from aqueous solutions
Visser, A. E., Swatloski, R. P., Reichert, W. M., Davis Jr., J. H., Rogers, R. D., Mayton, R., Sheff, S., & Wierzbicki, A. (2001) · Chemical Communications · doi:10.1039/b008041l · Cited by 920
Cited by
Han, X., & Armstrong, D. W. (2007) · Accounts of Chemical Research · doi:10.1021/ar700044y · Cited by 1,024
Ionic Liquids-Based Extraction: A Promising Strategy for the Advanced Nuclear Fuel Cycle
Sun, X., Luo, H., & Dai, S. (2012) · Chemical Reviews · doi:10.1021/cr200193x · Cited by 852
A review of ionic liquids towards supercritical fluid applications
Keskin, S., Kayrak-Talay, D., Akman, U., & Hortaçsu, Ö. (2007) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2007.05.013 · Cited by 739
Lanthanides and Actinides in Ionic Liquids
Binnemans, K. (2007) · Chemical Reviews · doi:10.1021/cr050979c · Cited by 672
Sethurajan, M., van Hullebusch, E. D., Fontana, D., Akcil, A., Deveci, H., Batinic, B., Leal, J. P., Gasche, T. A., Ali Kucuker, M., Kuchta, K., et al. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2018.1540760 · Cited by 412
Processing of metals and metal oxides using ionic liquids
Abbott, A. P., Frisch, G., Hartley, J., & Ryder, K. S. (2011) · Green Chemistry · doi:10.1039/c0gc00716a · Cited by 404
Ionic Liquids as Extraction Solvents: Where do We Stand?
Dietz, M. L. (2006) · Separation Science and Technology · doi:10.1080/01496390600743144 · Cited by 390
Extraction and separation of heavy rare earth elements: A review
Liu, T., & Chen, J. (2021) · Separation and Purification Technology · doi:10.1016/j.seppur.2021.119263 · Cited by 304
Billard, I., Ouadi, A., & Gaillard, C. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4478-x · Cited by 274
Patil, A. B., Pathak, P. N., Shinde, V. S., Alyapyshev, M. Y., Babain, V. A., & Mohapatra, P. K. (2015) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-015-4028-2 · Cited by 19
Metadata
- Authors
- Nakashima, K., Kubota, F., Maruyama, T., & Goto, M.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-05-07
- Volume
- 44
- Issue
- 12
- Pages
- 4368-4372
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2048833773
- Cited by
- 287
- References
- 30
- FWCI
- 29.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.