Robust PID Controller for Blood Glucose Regulation in Type I Diabetics
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Insulin injection therapy is widely practiced for the maintenance of blood glucose levels within the normoglycemic range (70−100 mg/dL) for type I diabetics. Several proportional−integral−derivative (PID) controllers are designed using classical and modern tuning techniques, for a diabetic to specify the insulin dosage on a continuous glucose measurement basis. The PID controllers are then assessed with a detailed physiological model of diabetic patients for their ability to reject meal disturbances and their robustness in the presence of parametric uncertainties. One of the recently developed PID tuning techniques is able to maintain the glucose concentration above the hypoglycemic range (<60 mg/dL) in 95% (and 100% with fine-tuning) of 577 diabetics tested, while rejecting both single- and multiple-meal disturbance(s).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bergman, R. N., Phillips, L. S., & Cobelli, C. (1981) · Journal of Clinical Investigation · doi:10.1172/jci110398 · Cited by 1,640
SIMON, C., BRANDENBERGER, G., & FOLLENIUS, M. (1987) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-64-4-669 · Cited by 147
Guyton, J. R., Foster, R. O., Soeldner, J. S., Tan, M. H., Kahn, C. B., Koncz, L., & Gleason, R. E. (1978) · Diabetes · doi:10.2337/diab.27.10.1027 · Cited by 127
Cited by
Hernández-Ordoñez, M., & Campos-Delgado, D. U. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.11.028 · Cited by 43
Design of a dual-hormone model predictive control for artificial pancreas with exercise model
Resalat, N., El Youssef, J., Reddy, R., & Jacobs, P. G. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591182 · Cited by 34
Panunzi, S., Pompa, M., Borri, A., Piemonte, V., & De Gaetano, A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237215 · Cited by 21
Metadata
- Authors
- Ramprasad, Y., Rangaiah, G. P., & Lakshminarayanan, S.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-11-30
- Volume
- 43
- Issue
- 26
- Pages
- 8257-8268
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2035320840
- Cited by
- 55
- References
- 3
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust PID Controller for Blood Glucose Regulation in Type I Diabetics. https://app.cochat.ai/papers/10.1021/ie049546a
- The paper
- Ramprasad, Y., Rangaiah, G. P., & Lakshminarayanan, S. (2004). Robust PID Controller for Blood Glucose Regulation in Type I Diabetics. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie049546a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.