The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Process Monitoring Based on Independent Component Analysis−Principal Component Analysis (ICA−PCA) and Similarity Factors
Abstract
Many of the current multivariate statistical process monitoring techniques (such as principal component analysis (PCA) or partial least squares (PLS)) do not utilize the non-Gaussian information of process data. This paper proposes a new monitoring method based on independent component analysis−principal component analysis (ICA−PCA). The Gaussian and non-Gaussian information can be extracted for fault detection and diagnosis. Moreover, a new mixed similarity factor is proposed. This similarity factor is used to identify the fault mode. Because of the non-orthogonal nature of the extracted independent components, a “main angle” is proposed to calculate the ICA-based similarity factor. To handle the cases where two datasets have similar principal components or independent components but the numerical values of the process variables are different, two distance similarity factors are used for complement. A case study of the Tennessee Eastman (TE) benchmark process indicates that the proposed fault detection and mode identification methods are more efficient, compared to the alternative methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
A plant-wide industrial process control problem
Downs, J. J., & Vogel, E. F. (1993) · Computers & Chemical Engineering · doi:10.1016/0098-1354(93)80018-i · Cited by 3,348
Model-based fault-detection and diagnosis – status and applications
Isermann, R. (2005) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2004.12.002 · Cited by 1,579
Monitoring batch processes using multiway principal component analysis
Nomikos, P., & MacGregor, J. F. (1994) · AIChE Journal · doi:10.1002/aic.690400809 · Cited by 1,483
Multivariate SPC Charts for Monitoring Batch Processes
Nomikos, P., & MacGregor, J. F. (1995) · Technometrics · doi:10.1080/00401706.1995.10485888 · Cited by 1,422
Fault Detection and Diagnosis in Industrial Systems
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9 · Cited by 1,318
A Multivariate Exponentially Weighted Moving Average Control Chart
Lowry, C. A., Woodall, W. H., Champ, C. W., & Rigdon, S. E. (1992) · Technometrics · doi:10.1080/00401706.1992.10485232 · Cited by 1,230
Multivariate statistical monitoring of process operating performance
Kresta, J. V., Macgregor, J. F., & Marlin, T. E. (1991) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450690105 · Cited by 989
Multiscale PCA with application to multivariate statistical process monitoring
Bakshi, B. R. (1998) · AIChE Journal · doi:10.1002/aic.690440712 · Cited by 839
Multi-way partial least squares in monitoring batch processes
Nomikos, P., & MacGregor, J. F. (1995) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(95)00043-7 · Cited by 737
Monitoring independent components for fault detection
Kano, M., Tanaka, S., Hasebe, S., Hashimoto, I., & Ohno, H. (2003) · AIChE Journal · doi:10.1002/aic.690490414 · Cited by 410
Subspace approach to multidimensional fault identification and reconstruction
Dunia, R. H., & Qin, S. J. (1998) · AIChE Journal · doi:10.1002/aic.690440812 · Cited by 382
Real-time monitoring for a process with multiple operating modes
Hwang, D., & Han, C. (1999) · Control Engineering Practice · doi:10.1016/s0967-0661(99)00038-6 · Cited by 177
SARBU, C., & POP, H. (2005) · Talanta · doi:10.1016/j.talanta.2004.08.047 · Cited by 169
Pattern matching in historical data
Johannesmeyer, M. C., Singhal, A. K., & Seborg, D. E. (2002) · AIChE Journal · doi:10.1002/aic.690480916 · Cited by 118
Diagnosis of process disturbances by statistical distance and angle measures
Raich, A., & Çınar, A. (1997) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(96)00299-2 · Cited by 103
Cited by
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Review of Recent Research on Data-Based Process Monitoring
Ge, Z., Song, Z., & Gao, F. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie302069q · Cited by 967
Self-citationData Mining and Analytics in the Process Industry: The Role of Machine Learning
Ge, Z., Song, Z., Ding, S. X., & Huang, B. (2017) · IEEE Access · doi:10.1109/access.2017.2756872 · Cited by 922
“recently, the ICA-based process monitoring method has been modified and improved, which can be adopted in more complex processes, such as time-varying processes, nonlinear processes, dynamic processes and batch process monitoring [57]–[63].”
MethodSelf-citationA deep belief network based fault diagnosis model for complex chemical processes
Zhang, Z., & Zhao, J. (2017) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2017.02.041 · Cited by 309
Zhu, J., Ge, Z., Song, Z., & Gao, F. (2018) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2018.09.003 · Cited by 308
Self-citation
Metadata
- Authors
- Ge, Z., & Song, Z.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-03-01
- Volume
- 46
- Issue
- 7
- Pages
- 2054-2063
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2070135905
- Cited by
- 294
- References
- 17
- FWCI
- 23.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.