Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Free Volume as the Basis of Gas Solubility and Selectivity in Imidazolium-Based Ionic Liquids

Shannon, Matthew S., Tedstone, Jason M., Danielsen, Scott P. O., Hindman, Michelle S., Irvin, A. Christopher, Bara, Jason E.·2012·Industrial & Engineering Chemistry Research

Abstract

While molar volume-based models for gas solubility in ionic liquids (ILs) have been proposed, free volume within the IL can be shown to be the underlying property driving gas solubility and selecitivity. Previously published observations as to the distinct differences in solubility trends for gases such as CH 4 and N 2 relative to CO 2 in systematically varied ILs can be attributed to positive and negative effects arising from increasing free volume with increasing alkyl chain length. Through the use of COSMOtherm as a powerful and rapid tool to calculate free volumes in 165 existing and theoretical 1- n -alkyl-3-methylimidazolium ([C n mim][X]) ILs, a previously unreported, yet speculated, critical underlying relationship between gas solubility in ILs is herein described. These results build upon previous assertions that Regular Solution Theory is applicable to imidazolium-based ILs, which appeared to indicate that a global maximum had already been observed for CO 2 solubility in imidazolium-based ILs. However, the findings of this computational study suggest that the perceived maximum in CO 2 solubility might be exceeded through rational design of ILs. We observe that although Henry’s constants in ILs are dependent on the inverse of molar volume and free volume, the volume-normalized solubility of CH 4 and N 2 are proportional to free volume, while CO 2 is inversely proportional to the square root of free volume. Our free volume model is compared to experimental data for CO 2 /CH 4 and CO 2 /N 2 selectivity, and a nearly identical plot of selectivity relative to IL molar volume can be generated from the computational method alone. The overall implication is that large, highly delocalized anions paired with imidazolium cations that have minimally sized alkyl chains may hold the key to achieving greater CO 2 solubility and selectivity in ILs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie202916e

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Shannon, M. S., Tedstone, J. M., Danielsen, S. P. O., Hindman, M. S., Irvin, A. C., & Bara, J. E.
Venue
Industrial & Engineering Chemistry Research
Published
2012-04-05
Volume
51
Issue
15
Pages
5565-5576
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2333543820
Cited by
243
References
1
FWCI
7.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.