The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
An amplified voltammetric sensor based on platinum nanoparticle/polyoxometalate/two-dimensional hexagonal boron nitride nanosheets composite and ionic liquid for determination of N-hydroxysuccinimide in water samples
Abstract
Abstract In this study, a novel electrochemical method as a conductive voltammetric sensor for determination of N-hydroxysuccinimide was developed. The N-hydroxysuccinimide sensor was achieved by carbon paste electrode (CPE) amplified with tri-component nanohybrid composite (Platinum nanoparticle/Polyoxometalate/Two-dimensional hexagonal boron nitride nanosheets) (PtNPs/POM/2D-hBN) and 1-hexyl-3-methylimidazolium chloride (HMICl) as conductive mediators. A significant decrease (110 mV) in the oxidation overvoltage and significant increased (2.4 times) in the current of the N-hydroxysuccinimide were observed using HMICl-PtNPs/POM/2D-hBN/POMBNS/CPE. Furthermore, the HMICl-PtNPs/POM/2D-hBN/POMBNS/CPE exhibited a good linearity from 0.1 to 300 μM and detection limit 60 nM for determination of N-hydroxysuccinimide. The capability to promote the electron exchange between N-hydroxysuccinimide and the HMICl-PtNPs/POM/2D-hBN/POMBNS/CPE exhibited a novel analytical strategy for fabrication of water pollutant sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Use of Esters of N-Hydroxysuccinimide in Peptide Synthesis
Anderson, G. W., Zimmerman, J. E., & Callahan, F. M. (1964) · Journal of the American Chemical Society · doi:10.1021/ja01063a037 · Cited by 1,240
Design principles of ion selective nanostructured membranes for the extraction of lithium ions
Razmjou, A., Asadnia, M., Hosseini, E., Habibnejad Korayem, A., & Chen, V. (2019) · Nature Communications · doi:10.1038/s41467-019-13648-7 · Cited by 616
Self-citationLarge-scale mechanical peeling of boron nitride nanosheets by low-energy ball milling
Li, L. H., Chen, Y., Behan, G., Zhang, H., Petravic, M., & Glushenkov, A. M. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm11192b · Cited by 492
Yola, M. L., Gupta, V. K., Eren, T., Şen, A. E., & Atar, N. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2013.12.086 · Cited by 417
Self-citationKarimi-Maleh, H., Tahernejad-Javazmi, F., Atar, N., Yola, M. L., Gupta, V. K., & Ensafi, A. A. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/ie504438z · Cited by 412
Self-citationKarimi-Maleh, H., & Arotiba, O. A. (2020) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2019.10.007 · Cited by 404
Self-citationKarimi-Maleh, H., Shafieizadeh, M., Taher, M. A., Opoku, F., Kiarii, E. M., Govender, P. P., Ranjbari, S., Rezapour, M., & Orooji, Y. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.112040 · Cited by 400
Self-citationAlavi-Tabari, S. A. R., Khalilzadeh, M. A., & Karimi-Maleh, H. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.01.034 · Cited by 305
Self-citationThe Role of Electrochemical Immunosensors in Clinical Analysis
Mollarasouli, F., Kurbanoglu, S., & Ozkan, S. A. (2019) · Biosensors · doi:10.3390/bios9030086 · Cited by 293
Karimi-Maleh, H., Fakude, C. T., Mabuba, N., Peleyeju, G. M., & Arotiba, O. A. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2019.07.047 · Cited by 286
Self-citation
Cited by
Tuning of metal oxides photocatalytic performance using Ag nanoparticles integration
Karimi-Maleh, H., Kumar, B. G., Rajendran, S., Qin, J., Vadivel, S., Durgalakshmi, D., Gracia, F., Soto-Moscoso, M., Orooji, Y., & Karimi, F. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2020.113588 · Cited by 429
Self-citationChen, Y.-G., He, X.-L.-S., Huang, J.-H., Luo, R., Ge, H.-Z., Wołowicz, A., Wawrzkiewicz, M., Gładysz-Płaska, A., Li, B., Yu, Q.-X., et al. (2021) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2021.112336 · Cited by 192
Metadata
- Authors
- Karimi-Maleh, H., Karimi, F., Malekmohammadi, S., Zakariae, N., Esmaeili, R., Rostamnia, S., Yola, M. L., Atar, N., Movaghgharnezhad, S., Rajendran, S., Razmjou, A., Orooji, Y., Agarwal, S., & Gupta, V. K.
- Venue
- Journal of Molecular Liquids
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 310
- Pages
- 113185
- ISSN
- 0167-7322 (ISSN-L)
- OpenAlex
- W3018877757
- Cited by
- 284
- References
- 35
- FWCI
- 21.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An amplified voltammetric sensor based on platinum nanoparticle/polyoxometalate/two-dimensional hexagonal boron nitride nanosheets composite and ionic liquid for determination of N-hydroxysuccinimide in water samples. https://app.cochat.ai/papers/10.1016/j.molliq.2020.113185
- The paper
- Karimi-Maleh, H., Karimi, F., Malekmohammadi, S., Zakariae, N., Esmaeili, R., Rostamnia, S., Yola, M. L., Atar, N., Movaghgharnezhad, S., Rajendran, S., Razmjou, A., Orooji, Y., Agarwal, S., & Gupta, V. K. (2020). An amplified voltammetric sensor based on platinum nanoparticle/polyoxometalate/two-dimensional hexagonal boron nitride nanosheets composite and ionic liquid for determination of N-hydroxysuccinimide in water samples. Journal of Molecular Liquids. https://doi.org/10.1016/j.molliq.2020.113185
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.