The DOI matches its Crossref record.
Photonic Crystal Chemical Sensors: pH and Ionic Strength
Abstract
Diffraction from a photonic crystal material composed of a hydrolyzed polymerized crystalline colloidal array (PCCA) can be used to sense pH and ionic strength. The PCCA is a polyacrylamide hydrogel which embeds a polystyrene crystalline colloidal array (CCA). The diffracted wavelength of the PCCA changes as the PCCA volume changes due to the alterations in the CCA lattice constant. We examine the pH and ionic strength dependence of the hydrolyzed PCCA volume by monitoring the Bragg diffracted wavelength. We also develop a zero free parameter quantitative model to describe the pH and ionic strength dependence of the hydrogel volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stimuli-responsive polymers and their applications
Wei, M., Gao, Y., Li, X., & Serpe, M. J. (2017) · Polymer Chemistry · doi:10.1039/c6py01585a · Cited by 1,298
Bio-inspired variable structural color materials
Zhao, Y., Xie, Z., Gu, H., Zhu, C., & Gu, Z. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15267c · Cited by 935
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Tunable Inverse Opal Hydrogel pH Sensors
Lee, Y. ‐., & Braun, P. V. (2003) · Advanced Materials · doi:10.1002/adma.200304588 · Cited by 526
Hydrogel-based devices for biomedical applications
Deligkaris, K., Tadele, T. S., Olthuis, W., & van den Berg, A. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.03.083 · Cited by 451
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370
Self-citationBioinspired Stimuli‐Responsive Color‐Changing Systems
Isapour, G., & Lattuada, M. (2018) · Advanced Materials · doi:10.1002/adma.201707069 · Cited by 348
Colorful humidity sensitive photonic crystal hydrogel
Tian, E., Wang, J., Zheng, Y., Song, Y., Jiang, L., & Zhu, D. (2008) · Journal of Materials Chemistry · doi:10.1039/b717368g · Cited by 344
Thermochromic Polymers—Function by Design
Seeboth, A., Lötzsch, D., Ruhmann, R., & Muehling, O. (2014) · Chemical Reviews · doi:10.1021/cr400462e · Cited by 316
Li, G. L., Möhwald, H., & Shchukin, D. G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35517a · Cited by 314
Magnetochromatic Microspheres: Rotating Photonic Crystals
Ge, J., Lee, H., He, L., Kim, J., Lu, Z., Kim, H., Goebl, J., Kwon, S., & Yin, Y. (2009) · Journal of the American Chemical Society · doi:10.1021/ja903626h · Cited by 261
Two-Dimensional Photonic Crystal Chemical and Biomolecular Sensors
Cai, Z., Smith, N. L., Zhang, J.-T., & Asher, S. A. (2015) · Analytical Chemistry · doi:10.1021/ac504679n · Cited by 216
Self-citationYetisen, A. K., Butt, H., Volpatti, L. R., Pavlichenko, I., Humar, M., Kwok, S. J. J., Koo, H., Kim, K. S., Naydenova, I., Khademhosseini, A., et al. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.10.005 · Cited by 192
Metadata
- Authors
- Lee, K., & Asher, S. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-09-13
- Volume
- 122
- Issue
- 39
- Pages
- 9534-9537
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2068557395
- Cited by
- 569
- References
- 0
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.