The DOI matches its Crossref record.
Potentiometric Sensors Based on the Inductive Effect on the p Ka of Poly(aniline): A Nonenzymatic Glucose Sensor
Abstract
The use of conjugated polymers for sensor applications continues to be the subject of intense research. In addition to their use as electronic conductors, they have been exploited as active sensing elements by coupling ligands to the backbone. In this approach, binding of an analyte results in physical distortions or changes in electron density, thereby altering conductivity. Poly(aniline), in particular, has received a great deal of attention due to its proton coupled redox chemistry and its resulting pH-dependent properties. For example, poly(aniline) has been used as a pH electrode and has been coupled to reactions that generate or consume protons to create sensors. Herein, we report a new strategy that exploits the inductive effect of reactive substituents on the pK_a of poly(aniline) to produce active sensing elements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Biomedical applications of boronic acid polymers
Cambre, J. N., & Sumerlin, B. S. (2011) · Polymer · doi:10.1016/j.polymer.2011.07.057 · Cited by 435
Highly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing
Yuan, J. H., Wang, K., & Xia, X. H. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400321 · Cited by 432
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Metadata
- Authors
- Shoji, E., & Freund, M. S.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-03-16
- Volume
- 123
- Issue
- 14
- Pages
- 3383-3384
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2091058145
- Cited by
- 343
- References
- 0
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Potentiometric Sensors Based on the Inductive Effect on the p Ka of Poly(aniline): A Nonenzymatic Glucose Sensor. https://app.cochat.ai/papers/10.1021/ja005906j
- The paper
- Shoji, E., & Freund, M. S. (2001). Potentiometric Sensors Based on the Inductive Effect on the p Ka of Poly(aniline): A Nonenzymatic Glucose Sensor. Journal of the American Chemical Society. https://doi.org/10.1021/ja005906j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.