Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Electronic Detection of Single-Base Mismatches in DNA with Ferrocene-Modified Probes

Yu, C. J., Wan, Yanjian, Yowanto, Handy, Li, Jie, Tao, Chunlin, James, Matthew D., Tan, Christine L., Blackburn, Gary F., Meade, Thomas J.·2001·Journal of the American Chemical Society

Abstract

Genotyping and gene-expression monitoring is critical to the study of the association between genetics and drug response (pharmacogenomics) and the association of sequence variation with heritable phenotypes. Recently, we developed an entirely electronic method for the detection of DNA hybridization events by the site-specific incorporation of ferrocenyl derivatives into DNA oligonucleotides. To perform rapid and accurate point mutation detection employing this methodology, two types of metal-containing signaling probes with varying redox potentials are required. In this report we describe a new ferrocene-containing phosphoramidite 9 that provides a range of detectable redox potentials. Using automated DNA/RNA synthesis techniques the two ferrocenyl complexes were inserted at various positions along oligonucleotide probes. Thermal stability analysis of these metal-containing DNA oligonucleotides indicates that incorporation of 9 resulted in no destabilization of the duplex. A mixture of oligonucleotides containing compounds 9 and I was analyzed by alternating current voltammetry (ACV) monitored at the 1st harmonic. The data demonstrate that the two ferrocenyl oligonucleotide derivatives can be distinguished electrochemically. A CMS-DNA array was prepared on an array of gold electrodes on a printed circuit board substrate with a self-assembled mixed monolayer, coupled to an electronic detection system. Experiments for the detection of a single-base match utilizing two signaling probes were carried out. The results demonstrate that rapid and accurate detection of a single-base mismatch can be achieved by using these dual-signaling probes on CMS-DNA chips.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja010045f

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 260

Metadata

Authors
Yu, C. J., Wan, Y., Yowanto, H., Li, J., Tao, C., James, M. D., Tan, C. L., Blackburn, G. F., & Meade, T. J.
Venue
Journal of the American Chemical Society
Published
2001-10-23
Volume
123
Issue
45
Pages
11155-11161
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2085475044
Cited by
260
References
4
FWCI
6.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electronic Detection of Single-Base Mismatches in DNA with Ferrocene-Modified Probes. https://app.cochat.ai/papers/10.1021/ja010045f
The paper
Yu, C. J., Wan, Y., Yowanto, H., Li, J., Tao, C., James, M. D., Tan, C. L., Blackburn, G. F., & Meade, T. J. (2001). Electronic Detection of Single-Base Mismatches in DNA with Ferrocene-Modified Probes. Journal of the American Chemical Society. https://doi.org/10.1021/ja010045f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.