The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Factors that Determine the Protein Resistance of Oligoether Self-Assembled Monolayers − Internal Hydrophilicity, Terminal Hydrophilicity, and Lateral Packing Density
Abstract
Protein resistance of oligoether self-assembled monolayers (SAMs) on gold and silver surfaces has been investigated systematically to elucidate structural factors that determine whether a SAM will be able to resist protein adsorption. Oligo(ethylene glycol) (OEG)-, oligo(propylene glycol)-, and oligo(trimethylene glycol)-terminated alkanethiols with different chain lengths and alkyl termination were synthesized as monolayer constituents. The packing density and chemical composition of the SAMs were examined by XPS spectroscopy; the terminal hydrophilicity was characterized by contact angle measurements. IRRAS spectroscopy gave information about the chain conformation of specific monolayers; the amount of adsorbed protein as compared to alkanethiol monolayers was determined by ellipsometry. We found several factors that in combination or by themselves suppress the protein resistance of oligoether monolayers. Monolayers with a hydrophobic interior, such as those containing oligo(propylene glycol), show no protein resistance. The lateral compression of oligo(ethylene glycol) monolayers on silver generates more highly ordered monolayers and may cause decreased protein resistance, but does not necessarily lead to an all-trans chain conformation of the OEG moieties. Water contact angles higher than 70 degrees on gold or 65 degrees on silver reduce full protein resistance. We conclude that both internal and terminal hydrophilicity favor the protein resistance of an oligoether monolayer. It is suggested that the penetration of water molecules in the interior of the SAM is a necessary prerequisite for protein resistance. We discuss and summarize the various factors which are critical for the functionality of "inert" organic films.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at Aurfaces
Prime, K. L., & Whitesides, G. M. (1991) · Science · doi:10.1126/science.252.5009.1164 · Cited by 1,831
Structure and reactivity of water at biomaterial surfaces
Vogler, E. A. (1998) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(97)00040-7 · Cited by 1,640
Prime, K. L., & Whitesides, G. M. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00076a032 · Cited by 1,620
Harder, P., Grunze, M., Dahint, R., Whitesides, G. M., & Laibinis, P. E. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp972635z · Cited by 1,290
Self-citationZwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Holmlin, R. E., Chen, X., Chapman, R. G., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la0015258 · Cited by 891
Effect of Surface Wettability on the Adsorption of Proteins and Detergents
Sigal, G. B., Mrksich, M., & Whitesides, G. M. (1998) · Journal of the American Chemical Society · doi:10.1021/ja970819l · Cited by 816
Arginine-Mediated RNA Recognition: the Arginine Fork
Calnan, B. J., Tidor, B., Biancalana, S., Hudson, D., & Frankel, A. D. (1991) · Science · doi:10.1126/science.252.5009.1167 · Cited by 744
Surveying for Surfaces that Resist the Adsorption of Proteins
Chapman, R. G., Ostuni, E., Takayama, S., Holmlin, R. E., Yan, L., & Whitesides, G. M. (2000) · Journal of the American Chemical Society · doi:10.1021/ja000774f · Cited by 600
Inoue, A., & Sanes, J. R. (1997) · Science · doi:10.1126/science.276.5317.1428 · Cited by 387
Feldman, K., Hähner, G., Spencer, N. D., Harder, P., & Grunze, M. (1999) · Journal of the American Chemical Society · doi:10.1021/ja991049b · Cited by 279
Self-citationDesai, N. P., & Hubbell, J. A. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90193-e · Cited by 265
Water and the acute biological response to surfaces
Vogler, E. A. (1999) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856299x00667 · Cited by 243
Pertsin, A. J., & Grunze, M. (2000) · Langmuir · doi:10.1021/la000340y · Cited by 220
Self-citationRecognition Molecule Directed Interfacing Between Semiconductor Quantum Dots and Nerve Cells
Winter, J. O., Liu, T. Y., Korgel, B. A., & Schmidt, C. E. (2001) · Advanced Materials · doi:10.1002/1521-4095(200111)13:22<1673::aid-adma1673>3.0.co;2-6 · Cited by 203
Fan, C., Teixeira, M., Moura, J., Moura, I., Hanh, H. B., Le Gall, J., Peck, H. D., & Hoffman, B. M. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00001a003 · Cited by 190
Schweiss, R., Welzel, P. B., Werner, C., & Knoll, W. (2001) · Langmuir · doi:10.1021/la001741g · Cited by 153
Svedhem, S., Hollander, C.-Å., Shi, J., Konradsson, P., Liedberg, B., & Svensson, S. C. T. (2001) · The Journal of Organic Chemistry · doi:10.1021/jo0012290 · Cited by 128
Pertsin, A. J., Hayashi, T., & Grunze, M. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp025747l · Cited by 108
Self-citationHydroxide Ion Adsorption on Self-Assembled Monolayers
Kreuzer, H. J., Wang, R. L. C., & Grunze, M. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0350839 · Cited by 107
Self-citationPertsin, A. J., Grunze, M., & Garbuzova, I. A. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp9806617 · Cited by 98
Self-citationGrafting of Alkanethiol-Terminated Poly(ethylene glycol) on Gold
Tokumitsu, S., Liebich, A., Herrwerth, S., Eck, W., Himmelhaus, M., & Grunze, M. (2002) · Langmuir · doi:10.1021/la0258953 · Cited by 85
Self-citationSastre‐Santos, Á., Díaz‐García, M. A., del Rey, B., Dhenaut, C., Zyss, J., Ledoux-Rak, I. N., Agulló-López, F., & Torres⊗, T. (1997) · The Journal of Physical Chemistry A · doi:10.1021/jp972361f · Cited by 77
Dicke, C., & Hähner, G. (2002) · Journal of the American Chemical Society · doi:10.1021/ja027447n · Cited by 68
Hayashi, T., Pertsin, A. J., & Grunze, M. (2002) · The Journal of Chemical Physics · doi:10.1063/1.1504436 · Cited by 63
Self-citation
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Protein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
Recent Developments and Practical Feasibility of Polymer‐Based Antifouling Coatings
Maan, A. M. C., Hofman, A. H., de Vos, W. M., & Kamperman, M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000936 · Cited by 725
Ma, H., Hyun, J., Stiller, P., & Chilkoti, A. (2004) · Advanced Materials · doi:10.1002/adma.200305830 · Cited by 680
Metadata
- Authors
- Herrwerth, S., Eck, W., Reinhardt, S., & Grunze, M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-07-15
- Volume
- 125
- Issue
- 31
- Pages
- 9359-9366
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1971237107
- Cited by
- 697
- References
- 24
- FWCI
- 17.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.