The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
A Novel Two-Fluorophore Approach to Ratiometric Sensing of Zn2+
Abstract
We present a small molecule ratiometric Zn2+-sensing system based on two fluorophores excited by visible light, a Zn2+-insensitive reporter fluorophore, coumarin 343, and a Zn2+-sensitive fluorescein-based compound, ZPA-1. The two fluorophores are linked by an ester to give Coumazin-1, a membrane-permeable, essentially nonfluorescent compound. Upon exposure to esterases, Coumazin-1 is hydrolyzed to its constituent fluorophores. Measurement of the ratio of coumarin emission at 488 nm (lambdaexc = 445 nm) and comparison with ZPA-1 emission at 534 nm (lambdaexc = 505 nm) affords information about the amount of sensor present as well as the amount of Zn2+ present. A generally applicable synthetic route to amide-functionalized ZP1 sensors is also described. The Zn2+-sensing properties of one member of this class are similar to those of the parent ZP1 sensor, with slightly tighter binding and lower background signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Tsien, R. Y., Pozzan, T., & Rink, T. J. (1982) · The Journal of cell biology · doi:10.1083/jcb.94.2.325 · Cited by 2,244
Femtomolar Sensitivity of Metalloregulatory Proteins Controlling Zinc Homeostasis
Outten, C. E., & O'Halloran, A. T. V. (2001) · Science · doi:10.1126/science.1060331 · Cited by 1,489
Chemical Communication in Water Using Fluorescent Chemosensors
Czarnik, A. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00046a003 · Cited by 943
Burdette, S. C., Walkup, G. K., Spingler, B., Tsien, R. Y., & Lippard, S. J. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010059l · Cited by 744
Self-citationContribution of Aerobic Photoheterotrophic Bacteria to the Carbon Cycle in the Ocean
Kolber, Z. S., Gerald, F., Plumley, Lang, A. S., Beatty, J. T., Blankenship, R. E., VanDover, C. L., Vetriani, C., Koblizek, M., Rathgeber, C., et al. (2001) · Science · doi:10.1126/science.1059707 · Cited by 462
Recent development of zinc-fluorophores
Kimura, E., & Koike, T. (1998) · Chemical Society Reviews · doi:10.1039/a827179z · Cited by 378
ZP4, an Improved Neuronal Zn2+ Sensor of the Zinpyr Family
Burdette, S. C., Frederickson, C. J., Bu, W., & Lippard, S. J. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0287377 · Cited by 363
Self-citationA Novel, Cell-Permeable, Fluorescent Probe for Ratiometric Imaging of Zinc Ion
Maruyama, S., Kikuchi, K., Hirano, T., Urano, Y., & Nagano, T. (2002) · Journal of the American Chemical Society · doi:10.1021/ja026442n · Cited by 307
A fluorescent PEBBLE nanosensor for intracellular free zinc
Sumner, J. P., Aylott, J. W., Monson, E., & Kopelman, R. (2002) · The Analyst · doi:10.1039/b108568a · Cited by 160
Frederickson, C. J., Suh, S. W., Koh, J., Yoo, K., Thompson, R. B., LaBuda, C. J., Balaji, R. V., & Cuajungco, M. P. (2002) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540205001210 · Cited by 81
Cited by
Metals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Luminescent sensors and switches in the early 21st century
Callan, J. F., de Silva, A. P., & Magri, D. C. (2005) · Tetrahedron · doi:10.1016/j.tet.2005.05.043 · Cited by 1,123
Synthetic fluorescent sensors for studying the cell biology of metals
Domaille, D. W., Que, E. L., & Chang, C. J. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.69 · Cited by 1,081
Jiang, P., & Guo, Z. (2004) · Coordination Chemistry Reviews · doi:10.1016/j.cct.2003.10.013 · Cited by 989
Metadata
- Authors
- Woodroofe, C. C., & Lippard, S. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-08-27
- Volume
- 125
- Issue
- 38
- Pages
- 11458-11459
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1993288267
- Cited by
- 259
- References
- 11
- FWCI
- 7.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.